9. CCD OUTPUT WAVEFORM TIMING CHART

( 1 ) Horizontal Output Waveform Timing Chart

One horizontal scan interval 780 clk

(31.8 s)

HD

78 clk

40.7 ns

(31.8s)

 

 

31 clk

CCD

output signal

72 clk 16 clk 2 clk

7 clk

 

 

4

Optical black Horizontal transfer

Dummy

 

 

 

 

 

 

 

 

 

clk

 

 

 

 

 

 

 

 

 

portion

stop interval

pixels

 

Total effective pixels 659 clk

 

 

 

 

 

 

 

 

 

Optical black

 

 

 

 

 

 

 

 

Horizontal blanking interval 132 clk

portion

Output video interval 648 clk

 

 

 

 

 

 

 

(5.38 s)

 

 

 

 

(26.4 s)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video

 

 

 

 

 

 

 

 

 

 

 

 

 

output signal

 

 

 

 

 

 

 

 

 

 

 

 

 

(Representative

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HSYNC

 

 

 

 

 

 

 

 

values)

 

 

 

 

 

 

 

 

 

 

 

18 clk

58 clk

56 clk

 

 

CLK=40.74 nsec

 

 

 

(0.73 s)

(2.36 s)

(2.28 s)

 

 

 

 

 

 

 

 

 

 

 

( 2 ) Vertical Output Waveform Timing Chart

VD

525H

9H

286 s

9H

286 s

525 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

HD

CCD

 

1 2

 

 

output signal

 

 

525

1

2 3 4 5 1 2 3 4 5 6 7 8

 

 

 

 

 

 

Dummy pixels Optical black

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

portion

 

Video

 

Vertical blanking interval 20H

 

 

 

output signal

 

 

(636

s)

 

(Representative

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

values)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

514 515 516 517 518 519 520 521 522 523 524 525 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Video output

493 494

 

 

1 2

496

525

1

2 3 4 5 1 2 3 4 5 6 7 8

Optical black

Dummy pixels Optical black

portion

portion

 

 

Vertical blanking interval 20H

(636 s)

33

Image 33
Contents For Customer Use IK-TF5Safety Precautions May occur in such places DisclaimerTable of Contents Components Available selectins Preset value Items Controlled by Using on Screen DisplayMenu Down button Connector Pin Assignments ConnectionStandard Connection White Balance OperationAutomatic White Balance Manual White Balance Outline Result displayed MeaningShutter speed mode is EXT Trig mode GainShading Correction Using the Menus Mode Setting by on Screen DisplayPartial read setting Changing each setting in Manu modeMenus Shutter Electronic shutterChanging the shutter speed setting Changing each setting in SS synchro. scan modeChanging each setting in 1P SNR mode Changing each setting in E.TRG modeChanging the polarity of inputting trigger pulse setting Changing 1P SNR exposure time settingChanging 1P SR exposure time setting Changing each setting in 1P SR modeChanging each setting in PW SNR mode Changing each setting in PW SR mode Changing each setting in Gain Changing each setting in RR modeChanging the gain in Manu mode Gain Video gainWHT BAL White balance Changing master pedestal Changing shading correction modeChanging R pedestal Changing B pedestalSync Adjusting horizontal phaseOption Changing RGB SyncExternal sync signal input conditions Setting to factory setting statusShutter mode HD input VD input External SyncUsing the unit with external sync signal Setting by the frameSetting by 1H Synchro. Scan OperationEXT Trig External trigger 1P SNR 1 Pulse Sync Non ResetVD OUT*3 Video Index 1 Pulse Trigger SYNC-RESET Picture Output Timing 1P SR 1 Pulse Sync ResetPW SNR Pulse width trigger SYNC-NON Reset Video output 525H 1 Pulse Width Trigger SYNC-RESET Picture Output Timing PW SR Pulse width trigger SYNC-RESETRR Reset restart Input Timing Chart ExampleLong Term Exposure Partial Read When Partial Scanning Mode is onPartial Scanning OFF All pixels scanning Partial Scanning onInput Output Signal Specificatoins CCD Output Waveform Timing Chart Horizontal Output Waveform Timing ChartVertical Output Waveform Timing Chart RGB, 3CCD SpecificationsExternal Appearance Diagram Before Making a Service CallSymptom Items to be checked Limited One 1 Year Warranty of Labor and Parts Step-by-step Procedures How to Obtain Warranty ServiceImaging Systems Division