7. 6 Partial Read
( 1 ) Partial Scanning OFF (All pixels scanning)
In this mode, all pixels independent signal from the VIDEO OUT connector is output each 1/60 second (Line order output).
External HD/VD sync is permitted.
Frame image | Frame image | Frame image |
1/60s (525H)
( 2 ) Partial Scanning ON
In this mode, the pixel signal of the vertical center portion from the VIDEO OUT connector is output each 1/180 second.
External HD/VD sync is permitted.
1/180s (175H)
( 3 ) When Partial Scanning Mode is ON
VD
9H
Video output
Blanking interval | Video interval | Blanking interval |
23H | 134H | 18H |
Total
175H
Video period
31