Toshiba IK-TF5 instruction manual PW SR Pulse width trigger SYNC-RESET

Page 29

( 4 ) PW SR (Pulse width trigger SYNC-RESET)

The trigger input to the RGB terminal develops 1 field images.

(4. 1) 1 Pulse Width Trigger SYNC-RESET Picture Output Timing

Negative polarity mode

Trigger*1

Positive polarity mode

About 1 s

About 7 s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exposure period*2

 

 

 

 

 

 

Exposure completion

to 1H

VD OUT*3

Video output

VIDEO INDEX

525H (Partial scanning OFF)

175H (Partial scanning ON)

*1: Externally input signal

*2: Exposure time = Trigger pulse width + 6 ms

(Valid trigger pulse width is 2 ms or greater for external trigger shutter operation.)

*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro- nized to this and output.

Note:

When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.

29

Image 29
Contents For Customer Use IK-TF5Safety Precautions May occur in such places DisclaimerTable of Contents Components Available selectins Preset value Items Controlled by Using on Screen DisplayMenu Down button Standard Connection Connector Pin AssignmentsConnection White Balance OperationAutomatic White Balance Manual White Balance Outline Result displayed MeaningShading Correction Shutter speed mode is EXT Trig modeGain Using the Menus Mode Setting by on Screen DisplayPartial read setting Changing each setting in Manu modeMenus Shutter Electronic shutterChanging the shutter speed setting Changing each setting in SS synchro. scan modeChanging each setting in 1P SNR mode Changing each setting in E.TRG modeChanging the polarity of inputting trigger pulse setting Changing 1P SNR exposure time settingChanging 1P SR exposure time setting Changing each setting in 1P SR modeChanging each setting in PW SNR mode Changing each setting in PW SR mode Changing each setting in Gain Changing each setting in RR modeChanging the gain in Manu mode Gain Video gainWHT BAL White balance Changing master pedestal Changing shading correction modeChanging R pedestal Changing B pedestalSync Adjusting horizontal phaseOption Changing RGB SyncExternal sync signal input conditions Setting to factory setting statusShutter mode HD input VD input External SyncUsing the unit with external sync signal Setting by the frameSetting by 1H Synchro. Scan OperationEXT Trig External trigger 1P SNR 1 Pulse Sync Non ResetVD OUT*3 Video Index 1 Pulse Trigger SYNC-RESET Picture Output Timing 1P SR 1 Pulse Sync ResetPW SNR Pulse width trigger SYNC-NON Reset Video output 525H 1 Pulse Width Trigger SYNC-RESET Picture Output Timing PW SR Pulse width trigger SYNC-RESETLong Term Exposure RR Reset restartInput Timing Chart Example Partial Read When Partial Scanning Mode is onPartial Scanning OFF All pixels scanning Partial Scanning onInput Output Signal Specificatoins Vertical Output Waveform Timing Chart CCD Output Waveform Timing ChartHorizontal Output Waveform Timing Chart RGB, 3CCD SpecificationsSymptom Items to be checked External Appearance DiagramBefore Making a Service Call Imaging Systems Division Limited One 1 Year Warranty of Labor and PartsStep-by-step Procedures How to Obtain Warranty Service