4.3Operational Commands

4.3Operational Commands

Five operational commands recognized by the SCANTEAM 3700 are: <A> – resets the 3700

DC4 – disables bar code scanning DC2 – enables bar code scanning <1> – serial trigger

<Z> – saves current configuration in non–volatile memory.

Explanations, ASCII and hex characters for the operational commands follow.

Reset Command <A>

 

 

COMMAND

ASCII

Hex Characters

Reset

<A>

3C 41 3E

Sending the operational command <A> causes the 3700 to reset. After reset the 3700 will operate according to the last configuration saved in non–volatile memory. If a valid configuration cannot be retrieved from memory, the 3700 will operate according to the default configuration.

Disable Decoding Command DC4

COMMAND

ASCII

Hex Characters

Disable Decoding

DC4

14

This is a single character command. Sending the operational command DC4 will cause the 3700 to stop looking at bar code data.

Enable Decoding Command DC2

COMMAND

ASCII

Hex Characters

Enable Decoding

DC2

12

This is a single character command. Sending the operational command DC2 will allow the 3700 to decode according to its current configuration.

Note: DC4 and DC2 are ASCII control characters. With a terminal emulation program running on a PC, send a DC4 by holding down the CTRL key while pressing the “T” key. Send a DC2 by holding down the CTRL key while pressing the “R” key.