Hand Held Products 3700 CCD manual B.4 Environmental Specifications, B.5 Mechanical Specifications

Models: 3700 CCD

1 76
Download 76 pages 13.18 Kb
Page 56
Image 56
Indicators:

Indicators:

Beeper.

 

See descriptions below.

Beeper

The good read/no read beeper indicator is configurable and can be disabled, if desired.

B.4 Environmental Specifications

Operating Temperature:

32° F to 122° F (0° C to +50° C)

Storage Temperature:

–40°F to 158° F (–40°C to +70° C)

Relative Operating

 

and Storage Humidity:

0 to 95% (non–condensing)

Barometric Pressure:

101,000 to 69,000 Pascals

 

(Sea level to 3000 meters)

ESD:

15 KV

A drain path for ESD should be provided when installing a 3700 in the host system.

Shock (Drop Test):

Sustains three (3) drops from 4 feet (1.2

 

meters) to a non–yielding surface

Mean Time Between

 

Failure (Ground Benign):

45,000 hrs. minimum

 

(will vary among models)

B.5 Mechanical Specifications

3700:

Width:

3.5 Inches (89mm)

 

Length:

2.9 Inches (75mm)

 

Height:

1.05 Inches (26m)

Interface Cables:

1) Welch Allyn p/n 42204595–01

 

Input/Output cable with 25 pin connector.

Note: A null modem is required for connection to a DTE type port.

Mounting Holes:

Four #6–32 UNC–2B (M3.5)

 

(Alternate dimensions available.)

B–4

Technical Specifications

Page 56
Image 56
Hand Held Products 3700 CCD manual B.4 Environmental Specifications, B.5 Mechanical Specifications, Indicators, Beeper