4.6Default Operating Parameters

The SCANTEAM 3700 is configured at the Hand Held Products factory with standard (default) operating parameters. The default configuration can be used as is or changed (reconfigured) by downloading new parameters over an RS–232 communications line from a host instrument. The default configuration settings are listed below.

Default Configuration Settings

ACK / NAK

Disabled

Baud Rate

9600

Beeper Mode

Disable beeper

Data Bits

7

No Read Message

“NR”

Parity

Even

Postamble

CR LF

Preamble

Port ID Code ID

Read Timeout

Timeout ends a read attempt, 1.5 seconds

RTS/CTS

Disabled

Stop Bit

1

Trigger Mode

Serial Trigger or External Trigger, Read Once

Votes

Voting set to 3 for port 1 and set to 1 for port 2

XON/XOFF

Disabled

Default Configuration: Symbology Settings

Codabar

Enabled

 

Send Start/Stop

Yes

 

Minimum Length

6

 

Maximum Length

60

Code 39

Enabled

 

Require Checksum

No

 

Send Checksum

No

 

Minimum Length

1

 

Maximum Length

48

Code 128

Enabled

 

Minimum Length

1

 

Maximum Length

80

I 2 of 5

Disabled

 

Require Checksum

No

 

Send Checksum

No

 

Minimum Length

6

 

Maximum Length

80

UPC A/E, EAN 8/13

Enabled

4–16

Configuring the SCANTEAM 3700

Page 42
Image 42
Hand Held Products 3700 CCD manual Default Operating Parameters, Default Configuration Settings