Hand Held Products 3700 CCD Set Code 39 Command Kp, Set Codabar Command Kq, Parameter, Ascii

Models: 3700 CCD

1 76
Download 76 pages 13.18 Kb
Page 38
Image 38
Set Code 39 Command Kp

Set Code 39 Command Kp

COMMAND <Kp enable, require checksum, send checksum, minimum length, maximum length>

Parameter

ASCII

Option

Enable

0

no

 

1

yes *

Require Checksum

0

no *

 

1

yes

Send Checksum

0

no *

 

1

yes

Minimum Length

 

Set from 1 to 48 * (1)

Maximum Length

 

Set from 1 to 48 * (48)

Sending the configuration command Kp sets Code 39 and all its parameters: enable/disable, require checksum, send checksum, minimum length, and maximum length. The default setting is Code 39 enabled, doesn’t require or send checksum, minimum length 1, and maximum length 48.

Set Codabar Command Kq

COMMAND <Kq enable, send start/stop, minimum length, maximum length>

Parameter

ASCII

Option

Enable

0

no

 

1

yes *

Send Start/Stop

0

no

 

1

yes *

Minimum Length

 

Set from 1 to 60 * (6)

Maximum Length

 

Set from 1 to 60 * (60)

Sending the configuration command Kq sets Codabar and all its parameters: enable/disable, send start/stop, minimum length, and maximum length. The default setting is Codabar enabled, send start/stop, minimum length 6, and maximum length 60.