Hand Held Products 3700 CCD Set Code 128 Command Kt, Set Beeper Mode Command Ku, scans per second

Models: 3700 CCD

1 76
Download 76 pages 13.18 Kb
Page 40
Image 40
Set Code 128 Command Kt

Set Code 128 Command Kt

COMMAND <Kt enable, minimum length, maximum length>

Parameter

ASCII

Option

Enable

0

no

 

1

yes *

Minimum Length

 

Set from 1 to 80 * (1)

Maximum Length

 

Set from 1 to 80 * (80)

Sending the configuration command Kt sets Code 128 and all its parameters: enable/disable, minimum length, and maximum length. The default setting is Code 128 enabled, minimum length 1, and maximum length 80.

Set Beeper Mode Command Ku

COMMAND <Ku mode_global, mode_port_1, mode_port_2, #>

Parameter

ASCII

Option

Mode

0

Disable beeper *

Mode

1

Enable beeper on valid read

Mode

2

Enable beeper on failed read

Sending the configuration command Ku sets the beeper mode. For example, if you wanted to enable the beeper for good reads on port 1; you would send the following command: <Ku , 1>. The default setting is Mode_global 0, with beeper disabled.

Set Scan Rate Command Kv

COMMAND <Kv rate, reserved, reserved>

Parameter

ASCII

Option

Rate

0

50 scans per second

Rate

1

100 scans per second

Rate

3

200 scans per second

The Kv command has been retained in the 3700 for compatibility with the SCANTEAM 3600, but the 3700 scan rate is fixed at the time of manufacture and cannot be changed by the Kv command. The <Kv?> status request (see next section) will report the scan rate setting.

4–14

Configuring the SCANTEAM 3700

Page 40
Image 40
Hand Held Products 3700 CCD manual Set Code 128 Command Kt, Set Beeper Mode Command Ku, Set Scan Rate Command Kv