Set Code 128 Command Kt
COMMAND <Kt enable, minimum length, maximum length>
Parameter | ASCII | Option |
Enable | 0 | no |
| 1 | yes * |
Minimum Length |
| Set from 1 to 80 * (1) |
Maximum Length |
| Set from 1 to 80 * (80) |
Sending the configuration command Kt sets Code 128 and all its parameters: enable/disable, minimum length, and maximum length. The default setting is Code 128 enabled, minimum length 1, and maximum length 80.
Set Beeper Mode Command Ku
COMMAND <Ku mode_global, mode_port_1, mode_port_2, #>
Parameter | ASCII | Option |
Mode | 0 | Disable beeper * |
Mode | 1 | Enable beeper on valid read |
Mode | 2 | Enable beeper on failed read |
Sending the configuration command Ku sets the beeper mode. For example, if you wanted to enable the beeper for good reads on port 1; you would send the following command: <Ku , 1>. The default setting is Mode_global 0, with beeper disabled.
Set Scan Rate Command Kv
COMMAND <Kv rate, reserved, reserved>
Parameter | ASCII | Option |
Rate | 0 | 50 scans per second |
Rate | 1 | 100 scans per second |
Rate | 3 | 200 scans per second |
The Kv command has been retained in the 3700 for compatibility with the SCANTEAM 3600, but the 3700 scan rate is fixed at the time of manufacture and cannot be changed by the Kv command. The <Kv?> status request (see next section) will report the scan rate setting.
Configuring the SCANTEAM 3700 |