JVC LWT0254-001B-H manual Duplex, Example connection with an RM-P2580, Simplex

Page 12

12 Connections & Installation (continued)

EN

Point-to-Point Communication System (continued)

Use twisted-pair cables for the connections.

Duplex

When the camera is controlled using the full duplex protocol,

set the Switch 5 of the Setting switch to ON.

Camera

Controller

RX +

 

TX +

RX -

 

TX -

TX +

 

RX +

TX -

 

RX -

Four wires must be connected.

 

Example (connection with an RM-P2580)

 

Camera

RM-P2580

RX +

C

C TX +

RX -

D

D TX -

TX +

A

A RX +

TX -

B

B RX -

Simplex

When the camera is controlled using the simplex transmission protocol, set the Switch 5 of the Setting switch

to ON.

Camera

Controller

RX +

TX +

RX -

TX -

Two wires must be connected.

Image 12
Contents For Customer Use Model No. TK-C625 Serial No LWT0254-001B-HSafety Precautions Risk of Electric Shock Do not OpenInformation Important Safeguards Characteristics ContentsOperating Precautions Preset positions → Refer toZooming operation Name and Function of Parts Ceiling Mount Setting Switch Side Camera Machine ID Machine ID Setting SwitchSetting Switch Auxiliary SwitchConnections & Installation Multi-Drop Communication SystemVideo SWITCHER, etc CAM2 Length of stub CAM32 Length of stub110 K Point-to-Point Communication System ACable ConnectionsB a pg Terminal side of the Ceiling MountDuplex Example connection with an RM-P2580Simplex Switch Settings ProtocolSync Machine ID Setting Switch Displayed as ID- LL. CheckMachine ID Installation Cable Connections Make a hole in the ceiling Connect the cable to this cameraRemove the Cover Lead the cable through the CoverConnecting an RG-59 coaxial cable Polyethylene Mesh Wires Core WireCable RatingConnect this to the remote control unit RM-P2580 Connect to an AC 24 V SupplyCable Within 10 cmInstalling the Ceiling Mount Attach the Safety WireFasten the ceiling mount to the ceiling Installing the Camera 20 ENSetup Procedure Setting Up the Camera Using RM-P258021Press and hold the Menu button for 3 seconds Press the SET buttonMenu Screen Configuration Setting Up the Camera Using RM-P258022 EN Private Mask Mode OFF 24 EN Camera Function 1 ScreenCamera Function 2 Screen AF for IR Tilt LimitPAN Limit Auto ReturnCamera TITLE/ALARM Screen 26 ENCamera ALC/VIDEO Screen 28 EN Auto PAN/PATROL/TRACE ScreenPOS. Function SET Screen Factory Settings Screen 30 ENPrivate Mask Setup Manual PAN Limit Setup Select a camera. ARM-P2580 AinstructionsbMenu screen display. a pg , steps 2 to Set the position for the left limitSettings that override the Manual Pan Limit Basic operation of Manual Pan LimitOperations that override the Manual Pan Limit Right LimitCamera Title Setup Tele Numeric Enter Button keys button Wide buttonMenu Screen Space Blinking Character areaArea Display Setup Title Press the FAR buttonRepeat Steps 5 to Menu buttonArea Display Setup Direction EastWest Camera buttonAlarm Title Setup Repeat steps 5 to 7 for each alarm titleCamera buttonNNumeric keyCamera NumberNENTER button Auto PAN Setup Set the Auto PAN Mode and Auto PAN SpeedSet the end position only when in the Return mode Select camera. ARM-P2580 AinstructionsbAuto Patrol Setup Change the Auto Patrol modeSet a patroll position Set the length of time a camera will stay in each positionAuto Trace Setup Set the patrol start positionCamera buttonNNumeric key Camera Number Nenter button To Start Auto Trace FunctionPosition Title Setup Select a preset position. a RM-P2580 AinstructionsbRepeat steps 5 to 7 for each title character Position buttonNNumeric key position numberNENTER buttonTroubleshooting 42 ENOther Specifications External Dimensions Unit mmPan/Tilt Mechanism GeneralVictor Company of Japan, Limited