Switch Settings

Set the switches on the Ceiling Mount before installing the camera. Settings vary according to configuration of the system used.

8Setting switches

Setting not required.

Set all to OFF.

AMachine ID Setting SwitchB (A pg. 14)

Switch 1 :

Invalid (Set to OFF)

Switch 2 :

Invalid (Set to OFF)

Switch 3 :

Invalid (Set to OFF)

Switch 4 :

PROTOCOL(1)

Switch 5 :

PROTOCOL(2)

Switch 6 :

SYNC

Switch 7 :

Invalid (Set to OFF)

Switch 8 :

RX TERM

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

RRESERVED (Switches 1, 2, 3) These switches must be set to OFF.

RPROTOCOL (1) (Switch 4)

Selects whether a single camera or multiple cameras are controlled in a system.

Set PROTOCOL(1) to Multi drop when connecting multiple cameras in series.

PROTOCOL (1)

Switch 4

 

 

 

Point-to-point

 

OFF

 

 

 

Multi-drop (when using the RM-P2580)

 

ON

 

 

 

(Initial setting: OFF)

When set to Multi-drop, be sure to set the Machine ID of each camera.

RPROTOCOL (2) (Switch 5)

Set this switch according to the communication protocol used when controlling the cameras.

 

PROTOCOL (2)

Switch 5

 

 

 

 

 

Duplex (when using the RM-P2580)

 

OFF

 

 

 

 

 

Simplex

 

ON

 

 

 

 

 

(Initial setting: OFF)

 

 

RSYNC (Switch 6)

When this switch is set to ON, the vertical sync of the camera becomes locked to the frequency of the AC power line.

SYNC

Switch 6

 

 

 

INT

 

OFF

 

 

 

LL

 

ON

 

 

 

(Initial setting: OFF)

(LL mode : TK-C625E : 50Hz ONLY TK-C625U : 60Hz ONLY)

RRESERVED (Switch 7)

This switch must be set to OFF.

RRX TERM (Switch 8)

This switch sets whether or not the section between control signal terminals RX + and RX - is to be terminated (with a resistance of 110 K).

 

RX Termination

 

 

Switch 8

 

 

 

 

 

 

 

Terminated (110 K)

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

 

OFF

 

 

 

 

 

 

 

(Initial setting: Terminated (110 K))

 

 

 

 

When the system in which this camera is used is a multidrop system (RS-485 system), set only the camera located at the extreme end of the control signal cables to ATerminatedB and set the other cameras to AOpenB.

Image 13
Contents Model No. TK-C625 Serial No LWT0254-001B-H For Customer UseRisk of Electric Shock Do not Open Safety PrecautionsInformation Important Safeguards Contents CharacteristicsOperating Precautions → Refer to Preset positionsZooming operation Name and Function of Parts Machine ID Machine ID Setting Switch Ceiling Mount Setting Switch Side CameraSetting Switch Auxiliary SwitchMulti-Drop Communication System Connections & InstallationCAM2 Length of stub CAM32 Length of stub Video SWITCHER, etc110 K ACable ConnectionsB a pg Terminal side of the Ceiling Mount Point-to-Point Communication SystemExample connection with an RM-P2580 DuplexSimplex Protocol Switch SettingsSync Displayed as ID- LL. Check Machine ID Setting SwitchMachine ID Installation Make a hole in the ceiling Connect the cable to this camera Cable ConnectionsRemove the Cover Lead the cable through the CoverPolyethylene Mesh Wires Core Wire Connecting an RG-59 coaxial cableCable RatingConnect to an AC 24 V Supply Connect this to the remote control unit RM-P2580Cable Within 10 cmAttach the Safety Wire Installing the Ceiling MountFasten the ceiling mount to the ceiling 20 EN Installing the CameraSetting Up the Camera Using RM-P258021 Setup ProcedurePress and hold the Menu button for 3 seconds Press the SET buttonSetting Up the Camera Using RM-P2580 Menu Screen Configuration22 EN Private Mask Mode OFF Camera Function 1 Screen 24 ENCamera Function 2 Screen Tilt Limit AF for IRPAN Limit Auto Return26 EN Camera TITLE/ALARM ScreenCamera ALC/VIDEO Screen Auto PAN/PATROL/TRACE Screen 28 ENPOS. Function SET Screen 30 EN Factory Settings ScreenPrivate Mask Setup Select a camera. ARM-P2580 Ainstructionsb Manual PAN Limit SetupMenu screen display. a pg , steps 2 to Set the position for the left limitBasic operation of Manual Pan Limit Settings that override the Manual Pan LimitOperations that override the Manual Pan Limit Right LimitTele Numeric Enter Button keys button Wide button Camera Title SetupMenu Screen Space Blinking Character areaPress the FAR button Area Display Setup TitleRepeat Steps 5 to Menu buttonEast Area Display Setup DirectionWest Camera buttonRepeat steps 5 to 7 for each alarm title Alarm Title SetupCamera buttonNNumeric keyCamera NumberNENTER button Set the Auto PAN Mode and Auto PAN Speed Auto PAN SetupSet the end position only when in the Return mode Select camera. ARM-P2580 AinstructionsbChange the Auto Patrol mode Auto Patrol SetupSet a patroll position Set the length of time a camera will stay in each positionSet the patrol start position Auto Trace SetupCamera buttonNNumeric key Camera Number Nenter button To Start Auto Trace FunctionSelect a preset position. a RM-P2580 Ainstructionsb Position Title SetupRepeat steps 5 to 7 for each title character Position buttonNNumeric key position numberNENTER button42 EN TroubleshootingOther External Dimensions Unit mm SpecificationsPan/Tilt Mechanism GeneralVictor Company of Japan, Limited