Connections & Installation (continued) | 13 |
EN |
Switch Settings
Set the switches on the Ceiling Mount before installing the camera. Settings vary according to configuration of the system used.
8Setting switches
Setting not required.
Set all to OFF.
AMachine ID Setting SwitchB (A pg. 14)
Switch 1 : | Invalid (Set to OFF) |
Switch 2 : | Invalid (Set to OFF) |
Switch 3 : | Invalid (Set to OFF) |
Switch 4 : | PROTOCOL(1) |
Switch 5 : | PROTOCOL(2) |
Switch 6 : | SYNC |
Switch 7 : | Invalid (Set to OFF) |
Switch 8 : | RX TERM |
ON |
|
|
|
|
|
|
|
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
RRESERVED (Switches 1, 2, 3) These switches must be set to OFF.
RPROTOCOL (1) (Switch 4)
Selects whether a single camera or multiple cameras are controlled in a system.
Set PROTOCOL(1) to Multi drop when connecting multiple cameras in series.
PROTOCOL (1) | Switch 4 | |
|
|
|
| OFF | |
|
|
|
| ON | |
|
|
|
(Initial setting: OFF)
When set to
RPROTOCOL (2) (Switch 5)
Set this switch according to the communication protocol used when controlling the cameras.
| PROTOCOL (2) | Switch 5 | |
|
|
|
|
| Duplex (when using the |
| OFF |
|
|
|
|
| Simplex |
| ON |
|
|
|
|
| (Initial setting: OFF) |
|
|
RSYNC (Switch 6)
When this switch is set to ON, the vertical sync of the camera becomes locked to the frequency of the AC power line.
SYNC | Switch 6 | |
|
|
|
INT |
| OFF |
|
|
|
LL |
| ON |
|
|
|
(Initial setting: OFF)
(LL mode :
RRESERVED (Switch 7)
This switch must be set to OFF.
RRX TERM (Switch 8)
This switch sets whether or not the section between control signal terminals RX + and RX - is to be terminated (with a resistance of 110 K).
| RX Termination |
|
| Switch 8 | |
|
|
|
|
|
|
| Terminated (110 K) |
|
|
| ON |
|
|
|
|
|
|
|
|
|
|
|
|
| Open |
|
|
| OFF |
|
|
|
|
|
|
| (Initial setting: Terminated (110 K)) |
|
|
|
|
When the system in which this camera is used is a multidrop system