Setting Up the Camera Using RM-P2580 (continued)37
EN
ALARM TITLE Setup
MENU button |
|
|
|
|
|
|
| ||
| SET button |
|
|
|
| PAN lever | |||
|
|
|
|
|
|
| |||
|
| CAMERA button |
|
|
|
| |||
|
|
|
|
|
| REMOTE CONTROL UNIT | |||
SETUP | CAMERA |
|
| POSITION |
|
|
|
| |
POWER |
|
|
|
|
|
|
| ||
MENU | SET | ALARM |
|
|
| AUTO | |||
|
| KEY LOCK |
|
|
|
|
|
|
|
| LENS |
| CAMERA/POSITION |
|
| PAN/TILT |
| ||
| SPEED | 1 | 2 | 3 | CAMERA | POSI- |
|
|
|
|
|
|
|
|
| TION |
|
|
|
| IRIS |
| 4 | 5 | 6 | 1 | 2 |
CLOSE | OPEN |
|
|
| OPTION | OPTION | |
NEAR | FOCUS | FAR | 7 | 8 | 9 | AUTO | AUTO |
| AF |
| PAN | PATROL | |||
WIDE | ZOOM | TELE | CLEAR | 0 | ENTER |
|
|
|
|
|
| /HOME |
|
|
|
FAR | Numeric | ENTER |
button | keys | button |
Use the ALARM TITLE screen to set the alarm titles to be displayed when an alarm signal is transmitted. Up to 10 alarm titles (ALARM TITLE 1 to 10) can be set and each title can be up to 12 characters in length.
1 Select the camera. (A RM-P2580 AINSTRUCTIONSB)
CAMERA buttonNNumeric key(Camera Number)NENTER button
●The picture of the selected camera is output.
2 Display the MENU screen. (A pg. 21, steps 2 to 4)
MENU button (3 sec.) N Select ACAMERA..B using the PAN lever N SET button.
●The AMENUB screen will be displayed.
3 Tilt the PAN lever up or down to move the cursor (E) to ACAM. TITLE/ALARM..B and press the SET button.
●The ACAMERA TITLE/ALARMB screen is displayed.
4 Move the cursor (E) to the AALARM TITLE EDIT..B item and press the SET button.
WIDE button
NEAR button
MENU
CAM.FUNCTION1..
CAM.FUNCTION2..
CAM.TITLE/ALARM..
CAM.ALC/VIDEO..
AUTO PAN/PATROL/TRACE..
POS.FUNCTION SET..
FACTORY SETTINGS..
<MENU> EXIT <SET> SUB MENU
MENU Screen
CAMERA TITLE / ALARM
CAM.TITLE EDIT.. |
|
AREA DISPLAY | OFF |
ALARM TITLE SIZE | DOUBLE |
ALARM TITLE EDIT.. |
|
ALARM INPUT.. |
|
ALARM OUTPUT.. |
|
<MENU> RETURN <SET> SUB MENU
CAMERA TITLE/ALARM Screen
Space | Blinking |
|
|
| Character area | ||
| ALARM TITLE EDIT |
| No.∗ ∗ |
| |||
| 0123456789ABCDEFGHIJKLMNO |
| |||||
PQRSTUVWXYZabcdefghijklmno | A MENO | ||||||
p q r s t u v w x y z ÄÖÜÊÎÔÛÇÑäëïöü | |||||||
| |||||||
âê î ô û á é í ó ú à è ì ò ù ç ñ ß ¡ ¿ . , ’ |
| ||||||
( ) < > |
|
|
|
|
| ||
CLR CANCEL [ | ] | [ | ] | INS DEL |
| ||
|
| W | T |
|
|
| |
<FOCUS KEY> ALARM No . SELECT |
| ||||||
<MENU> RETURN <SET> CHAR .SET |
| ||||||
| [ |
|
|
| ] |
|
ALARM TITLE EDIT Screen | Title input |
| |
| field |
●The AALARM TITLE EDIT No.1B screen will be displayed.
●The first character appears blinking and input is enabled.
5 Use the PAN lever to select the first character of the title from the character area.
●The selected character will appear blinking.
●The selected character is displayed in the title input field.
6 Press the SET button.
●The first character of the title is now confirmed, and input of the second character is possible.
●If the WIDE button is pressed, the title input field moves to the left. Use this to correct previously input characters.
7 Press the FAR button.
●The next AALARM TITLE EDIT No.2B screen is displayed.
●If the NEAR button is pressed, the previous AALARM TITLE EDIT No.1B screen is displayed.
8 Repeat steps 5 to 7 for each alarm title.
Complete the input of all the alarm titles (AALARM TITLE EDITB 1 to 10) in the same way.
9 Press the MENU button.
●The screen returns to the previous menu.
MEMO
●Only displayed for the
APress and hold the MENU button for 3 seconds to display the SETUP screen on the remote control unit.
BFirst select the ACONTROL UNIT..B screen, then the ADATA I/OB screen and finally the AINPUT ASSIGNMENTB screen.
CSelect AALARM TEXTB then AEDIT 1B, the alarm title set as AALARM TITLE EDIT 1B is displayed on the monitor. * The alarm signals are input into the DATA I/O terminals on the rear panel of the