JVC LWT0254-001B-H manual Machine ID Setting Switch, Displayed as ID- LL. Check

Page 14

14 Connections & Installation (continued)

EN

Switch Settings (continued)

8Machine ID Setting Switch

When controlling the system using a multi-drop remote control unit such as RM-P2580, for instance, assign a number (machine ID) for identification to each of the connected cameras.

Assign a machine ID according to the video input number of RM-P2580.

RCeiling Mount (Setting Switch Side)

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

Machine ID

 

 

<Procedures for Checking Machine ID>

1 Output video image for checking to the monitor 2 Turn on the power (AC 24 V) of the camera

3 Camera initializes

The following message will appear.

>>INITIAL PROCESS<<

PAN : - - I - -

TILT : - - I - -

PROTCOL DUPLEX : ID-01

Check that this is displayed as

Displayed as ID-LL. Check

“DUPLEX”

that the number LL is correct.

4 Check to ensure that “DUPLEX” and AID-LLBare displayed, and whether the number coincides with the video input number of RM-P2580. If the number is incorrect, re-set the machine ID.

MEMO

For systems using RM-P2580, a set of control signal cables are connected to multiple cameras during use. Errors in the switch setting of any one of the cameras will therefore cause malfunction in the entire system.

Image 14
Contents For Customer Use Model No. TK-C625 Serial No LWT0254-001B-HInformation Safety PrecautionsRisk of Electric Shock Do not Open Important Safeguards Characteristics ContentsOperating Precautions Zooming operation Preset positions→ Refer to Name and Function of Parts Setting Switch Ceiling Mount Setting Switch Side CameraMachine ID Machine ID Setting Switch Auxiliary SwitchConnections & Installation Multi-Drop Communication System110 K Video SWITCHER, etcCAM2 Length of stub CAM32 Length of stub Point-to-Point Communication System ACable ConnectionsB a pg Terminal side of the Ceiling MountSimplex DuplexExample connection with an RM-P2580 Sync Switch SettingsProtocol Machine ID Setting Switch Displayed as ID- LL. CheckMachine ID Installation Remove the Cover Cable ConnectionsMake a hole in the ceiling Connect the cable to this camera Lead the cable through the CoverCable Connecting an RG-59 coaxial cablePolyethylene Mesh Wires Core Wire RatingCable Connect this to the remote control unit RM-P2580Connect to an AC 24 V Supply Within 10 cmFasten the ceiling mount to the ceiling Installing the Ceiling MountAttach the Safety Wire Installing the Camera 20 ENPress and hold the Menu button for 3 seconds Setup ProcedureSetting Up the Camera Using RM-P258021 Press the SET button22 EN Menu Screen ConfigurationSetting Up the Camera Using RM-P2580 Private Mask Mode OFF Camera Function 2 Screen 24 ENCamera Function 1 Screen PAN Limit AF for IRTilt Limit Auto ReturnCamera TITLE/ALARM Screen 26 ENCamera ALC/VIDEO Screen 28 EN Auto PAN/PATROL/TRACE ScreenPOS. Function SET Screen Factory Settings Screen 30 ENPrivate Mask Setup Menu screen display. a pg , steps 2 to Manual PAN Limit SetupSelect a camera. ARM-P2580 Ainstructionsb Set the position for the left limitOperations that override the Manual Pan Limit Settings that override the Manual Pan LimitBasic operation of Manual Pan Limit Right LimitMenu Screen Camera Title SetupTele Numeric Enter Button keys button Wide button Space Blinking Character areaRepeat Steps 5 to Area Display Setup TitlePress the FAR button Menu buttonWest Area Display Setup DirectionEast Camera buttonCamera buttonNNumeric keyCamera NumberNENTER button Alarm Title SetupRepeat steps 5 to 7 for each alarm title Set the end position only when in the Return mode Auto PAN SetupSet the Auto PAN Mode and Auto PAN Speed Select camera. ARM-P2580 AinstructionsbSet a patroll position Auto Patrol SetupChange the Auto Patrol mode Set the length of time a camera will stay in each positionCamera buttonNNumeric key Camera Number Nenter button Auto Trace SetupSet the patrol start position To Start Auto Trace FunctionRepeat steps 5 to 7 for each title character Position Title SetupSelect a preset position. a RM-P2580 Ainstructionsb Position buttonNNumeric key position numberNENTER buttonOther Troubleshooting42 EN Pan/Tilt Mechanism SpecificationsExternal Dimensions Unit mm GeneralVictor Company of Japan, Limited