JVC LWT0254-001B-H Connect this to the remote control unit RM-P2580, Connect to an AC 24 V Supply

Page 18

18 Connections & Installation (continued)

EN

Cable Connections (continued)

Connection of Control Signal Cables

Connect this to the remote control unit (RM-P2580).

The maximum permissible length of the control signal cable during connection with RM-P2580 is 1200m. (RM-P2580 allows connection of a set of cables to multiple cameras. In this case, the total length of the cables shall not exceed 1200m.)

AFollow the diagram below to loosen and remove the screws on the two edges of the terminal block.

BStrip the coating of the control signal cable by about 4 mm before inserting it into the terminal.

CTurn the screw on the side to fasten the control signal cable.

DUpon fastening the control signal cable, re-install the terminal block that has been dismantled in A.

Connection of Power

Connect to an AC 24 V Supply.

 

Connect to AC 24 V power

Power Cable

supply. Listed class 2 input

only.

 

Connect the AC 24 V power cable to the AC 24 V input terminal of the terminal block. When doing so, use of a lug plate is recommended for connection to the AC 24 V terminal to prevent connection errors and disconnection of cables.

B

A Cable

C

D

A

MEMO

Instead of using 0.65, 4-core cables (2 pairs), it is recommended that twisted pair cables (category 3 and above) for use with Ethernet be used.

Cables with a thickness between 0.4 mm to 1.3 mm can be used.

Connect the control signal cables so that TX+ and TX- form a pair and RX+ and RX- form another.

To reduce the radiation of the Control Signal Cables connecting to this unit, make sure to mount the provided Ferrite Core.

Within 10 cm

Wind once

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control Signal

FerriteCables

Core

Wire Clamp

Ceiling Mount

CAUTIONS

Mount the Ferrite Core as close as possible the camera (within 10 cm).

Secure the Ferrite Core with the provided Wire Clamp.

Pass the wire through the Ferrite Core once before connecting to the camera.

When a 2-conductor VVF (vinyl-insulated vinyl sheath cable) is used, the maximum connection lengths are as follows. (Reference values)

Maximum

100 m

260 m

410 m

500 m

Connection Length

 

 

 

 

 

 

 

 

 

Conductor

R1.2 or

R1.8 or

R2.3 or

R2.9 or

Diameter

more

more

more

more

 

 

 

 

 

CAUTIONS

When thin cables are used, the cable resistance increases. As a result, the effective voltage will drop when the power consumption of the unit is at its maximum level (during simultaneous operation of panning and tilting). As such, use thicker cables with lower resistance, or decrease the cable length by installing the power supply unit near the camera, such that voltage drop upon flow of the rated current of the camera does not exceed 10%. When the voltage drops while the camera is in use, performance may become unstable and preset positions may not be reproduced accurately.

The internal circuit may be damaged if the cable is connected by mistake. In this case, ensure that you stop using and contact the nearest JVC dealers.

Image 18
Contents For Customer Use Model No. TK-C625 Serial No LWT0254-001B-HSafety Precautions Risk of Electric Shock Do not OpenInformation Important Safeguards Characteristics ContentsOperating Precautions Preset positions → Refer toZooming operation Name and Function of Parts Setting Switch Ceiling Mount Setting Switch Side CameraMachine ID Machine ID Setting Switch Auxiliary SwitchConnections & Installation Multi-Drop Communication SystemVideo SWITCHER, etc CAM2 Length of stub CAM32 Length of stub110 K Point-to-Point Communication System ACable ConnectionsB a pg Terminal side of the Ceiling MountDuplex Example connection with an RM-P2580Simplex Switch Settings ProtocolSync Machine ID Setting Switch Displayed as ID- LL. CheckMachine ID Installation Remove the Cover Cable ConnectionsMake a hole in the ceiling Connect the cable to this camera Lead the cable through the CoverCable Connecting an RG-59 coaxial cablePolyethylene Mesh Wires Core Wire RatingCable Connect this to the remote control unit RM-P2580Connect to an AC 24 V Supply Within 10 cmInstalling the Ceiling Mount Attach the Safety WireFasten the ceiling mount to the ceiling Installing the Camera 20 ENPress and hold the Menu button for 3 seconds Setup ProcedureSetting Up the Camera Using RM-P258021 Press the SET buttonMenu Screen Configuration Setting Up the Camera Using RM-P258022 EN Private Mask Mode OFF 24 EN Camera Function 1 ScreenCamera Function 2 Screen PAN Limit AF for IRTilt Limit Auto ReturnCamera TITLE/ALARM Screen 26 ENCamera ALC/VIDEO Screen 28 EN Auto PAN/PATROL/TRACE ScreenPOS. Function SET Screen Factory Settings Screen 30 ENPrivate Mask Setup Menu screen display. a pg , steps 2 to Manual PAN Limit SetupSelect a camera. ARM-P2580 Ainstructionsb Set the position for the left limitOperations that override the Manual Pan Limit Settings that override the Manual Pan LimitBasic operation of Manual Pan Limit Right LimitMenu Screen Camera Title SetupTele Numeric Enter Button keys button Wide button Space Blinking Character areaRepeat Steps 5 to Area Display Setup TitlePress the FAR button Menu buttonWest Area Display Setup DirectionEast Camera buttonAlarm Title Setup Repeat steps 5 to 7 for each alarm titleCamera buttonNNumeric keyCamera NumberNENTER button Set the end position only when in the Return mode Auto PAN SetupSet the Auto PAN Mode and Auto PAN Speed Select camera. ARM-P2580 AinstructionsbSet a patroll position Auto Patrol SetupChange the Auto Patrol mode Set the length of time a camera will stay in each positionCamera buttonNNumeric key Camera Number Nenter button Auto Trace SetupSet the patrol start position To Start Auto Trace FunctionRepeat steps 5 to 7 for each title character Position Title SetupSelect a preset position. a RM-P2580 Ainstructionsb Position buttonNNumeric key position numberNENTER buttonTroubleshooting 42 ENOther Pan/Tilt Mechanism SpecificationsExternal Dimensions Unit mm GeneralVictor Company of Japan, Limited