JVC LWT0254-001B-H manual Characteristics, Contents

Page 4

4 Introduction

EN

Thank you for purchsing this product.

(These instructions are for TK-C625U/TK-C625E) TK-C625U : For North American Market. TK-C625E : For European Market.

“TK-C625” is used for common descriptions between both models in this manual.

Before beginning to operate this unit, please read the instruction manual carefully in order to make sure that the best possible performance is obtained.

Characteristics

8Day/Night Surveillance

When the light is low, the camera is able to switch automatically to the high-sensitive (B&W) mode by turning the IR cut filter to ON/ OFF.

8Private Mask feature

This feature enables setting to mask a certain portion of the shooting area if it is to be hidden.

8Optical Zoom

Closer surveillance is made possible using the x12 optical zoom lens.

8Use of a bright zoom lens

Maximum aperture ratio of F 1.6 (at the Wide end) and use of a bright zoom lens produces a highly sensitive color mode of 3.6 lx (AGC 20 dB, 50%).

8High-speed Rotating Table

High-speed rotating table with a horizontal panning speed of 180°/sec and vertical tilting speed of 120°/sec makes it possible to recall a preset position quickly.

8High image quality

Uses a camera with a high resolution of 0.38 mega pixels and a highly sensitive CCD to realize a high image quality of 540 lines (Typ.) and S/N50dB.

Contents

 

Safety Precautions

2

IMPORTANT SAFEGUARDS

3

Introduction

4

Characteristics

4

Contents

4

Operating Precautions

5

Name and Function of Parts

7

Connections & Installation

9

Multi-Drop Communication System

9

Point-to-Point Communication System

11

Switch Settings

13

Cable Connections

16

Installing the Ceiling Mount

19

Installing the Camera

20

Setting Up the Camera Using RM-P2580

21

Setup Procedure

21

Menu Screen Configuration

22

CAMERA FUNCTION 1 Screen

24

CAMERA FUNCTION 2 Screen

24

CAMERA TITLE/ALARM Screen

26

CAMERA ALC/VIDEO Screen

27

AUTO PAN/PATROL/TRACE Screen

28

POS. FUNCTION SET Screen

29

FACTORY SETTINGS Screen

30

PRIVATE MASK Setup

31

MANUAL PAN LIMIT Setup

32

CAMERA TITLE Setup

34

AREA DISPLAY Setup (TITLE)

35

AREA DISPLAY Setup (DIRECTION)

36

ALARM TITLE Setup

37

AUTO PAN Setup

38

AUTO PATROL Setup

39

AUTO TRACE Setup

40

POSITION TITLE Setup

41

Other

42

Troubleshooting

42

Specifications

43

How to Use This Manual

MEMO : Points to pay attention to during operation.

CAUTION : Details for reference, such as functions or constraints during use.

A: Pages or items to refer to.

Image 4
Contents For Customer Use Model No. TK-C625 Serial No LWT0254-001B-HRisk of Electric Shock Do not Open Safety PrecautionsInformation Important Safeguards Characteristics ContentsOperating Precautions → Refer to Preset positionsZooming operation Name and Function of Parts Ceiling Mount Setting Switch Side Camera Machine ID Machine ID Setting SwitchSetting Switch Auxiliary SwitchConnections & Installation Multi-Drop Communication SystemCAM2 Length of stub CAM32 Length of stub Video SWITCHER, etc110 K Point-to-Point Communication System ACable ConnectionsB a pg Terminal side of the Ceiling MountExample connection with an RM-P2580 DuplexSimplex Protocol Switch SettingsSync Machine ID Setting Switch Displayed as ID- LL. CheckMachine ID Installation Cable Connections Make a hole in the ceiling Connect the cable to this cameraRemove the Cover Lead the cable through the CoverConnecting an RG-59 coaxial cable Polyethylene Mesh Wires Core WireCable RatingConnect this to the remote control unit RM-P2580 Connect to an AC 24 V SupplyCable Within 10 cmAttach the Safety Wire Installing the Ceiling MountFasten the ceiling mount to the ceiling Installing the Camera 20 ENSetup Procedure Setting Up the Camera Using RM-P258021Press and hold the Menu button for 3 seconds Press the SET buttonSetting Up the Camera Using RM-P2580 Menu Screen Configuration22 EN Private Mask Mode OFF Camera Function 1 Screen 24 ENCamera Function 2 Screen AF for IR Tilt LimitPAN Limit Auto ReturnCamera TITLE/ALARM Screen 26 ENCamera ALC/VIDEO Screen 28 EN Auto PAN/PATROL/TRACE ScreenPOS. Function SET Screen Factory Settings Screen 30 ENPrivate Mask Setup Manual PAN Limit Setup Select a camera. ARM-P2580 AinstructionsbMenu screen display. a pg , steps 2 to Set the position for the left limitSettings that override the Manual Pan Limit Basic operation of Manual Pan LimitOperations that override the Manual Pan Limit Right LimitCamera Title Setup Tele Numeric Enter Button keys button Wide buttonMenu Screen Space Blinking Character areaArea Display Setup Title Press the FAR buttonRepeat Steps 5 to Menu buttonArea Display Setup Direction EastWest Camera buttonRepeat steps 5 to 7 for each alarm title Alarm Title SetupCamera buttonNNumeric keyCamera NumberNENTER button Auto PAN Setup Set the Auto PAN Mode and Auto PAN SpeedSet the end position only when in the Return mode Select camera. ARM-P2580 AinstructionsbAuto Patrol Setup Change the Auto Patrol modeSet a patroll position Set the length of time a camera will stay in each positionAuto Trace Setup Set the patrol start positionCamera buttonNNumeric key Camera Number Nenter button To Start Auto Trace FunctionPosition Title Setup Select a preset position. a RM-P2580 AinstructionsbRepeat steps 5 to 7 for each title character Position buttonNNumeric key position numberNENTER button42 EN TroubleshootingOther Specifications External Dimensions Unit mmPan/Tilt Mechanism GeneralVictor Company of Japan, Limited