1 Attach the Safety Wire

4 Turn the camera

Follow the diagram to pull out the Safety Wire from the ceiling mount, followed by hanging it to the Fastening Hook for Safety Wire on the camera.

Safety Wire

Fastening Hook for

Safety Wire

CAUTION

Be sure to connect the Safety Wire. Otherwise, the camera may fall to the ground.

Do not leave the camera hanging from the Safety Wire. The spring of the Safety Wire may lose its elasticity, and wire may get caught, thus preventing the camera to fit properly to the ceiling mount.

2 Check that the Locking Screw is loosened

The camera cannot be properly installed if the Locking Screw of the ceiling mount is not loosened.

3 Fit the camera to the ceiling mount

Fit the camera to the ceiling mount by aligning the AF markB of the camera with the AG markB of the ceiling mount. Additionally, check the positions of the Camera Clamping Bracket and the Locking Screw of the ceiling mount before fitting the camera.

Ceiling Mount

Locking Screw

AGMarkB

Camera

Camera

Clamping

Bracket

Make sure that the camera is not tilted, followed by pushing the camera against the ceiling mount and turning it in the clockwise direction until it stops.Upon doing so, check that the Camera Clamping Bracket is aligned with the position of the Locking Screw of the ceiling mount.

Camera Clamping Bracket

Locking Screw

Turn camera in clockwise direction

5 Fasten the Locking Screw

Fasten the Locking Screw using a Phillips-head screwdriver.

Locking Screw

Fasten the Locking

Screw

CAUTION

If the Locking Screw is not securely fastened, the camera may vibrate or fall down. Be sure to fasten the Locking Screw firmly.

To dismantle the camera, perform procedure from 1 to 5 in the reverse order.

Image 20
Contents For Customer Use Model No. TK-C625 Serial No LWT0254-001B-HInformation Safety PrecautionsRisk of Electric Shock Do not Open Important Safeguards Characteristics ContentsOperating Precautions Zooming operation Preset positions→ Refer to Name and Function of Parts Ceiling Mount Setting Switch Side Camera Machine ID Machine ID Setting SwitchSetting Switch Auxiliary SwitchConnections & Installation Multi-Drop Communication System110 K Video SWITCHER, etcCAM2 Length of stub CAM32 Length of stub Point-to-Point Communication System ACable ConnectionsB a pg Terminal side of the Ceiling MountSimplex DuplexExample connection with an RM-P2580 Sync Switch SettingsProtocol Machine ID Setting Switch Displayed as ID- LL. CheckMachine ID Installation Cable Connections Make a hole in the ceiling Connect the cable to this cameraRemove the Cover Lead the cable through the CoverConnecting an RG-59 coaxial cable Polyethylene Mesh Wires Core WireCable RatingConnect this to the remote control unit RM-P2580 Connect to an AC 24 V SupplyCable Within 10 cmFasten the ceiling mount to the ceiling Installing the Ceiling MountAttach the Safety Wire Installing the Camera 20 ENSetup Procedure Setting Up the Camera Using RM-P258021Press and hold the Menu button for 3 seconds Press the SET button22 EN Menu Screen ConfigurationSetting Up the Camera Using RM-P2580 Private Mask Mode OFF Camera Function 2 Screen 24 ENCamera Function 1 Screen AF for IR Tilt LimitPAN Limit Auto ReturnCamera TITLE/ALARM Screen 26 ENCamera ALC/VIDEO Screen 28 EN Auto PAN/PATROL/TRACE ScreenPOS. Function SET Screen Factory Settings Screen 30 ENPrivate Mask Setup Manual PAN Limit Setup Select a camera. ARM-P2580 AinstructionsbMenu screen display. a pg , steps 2 to Set the position for the left limitSettings that override the Manual Pan Limit Basic operation of Manual Pan LimitOperations that override the Manual Pan Limit Right LimitCamera Title Setup Tele Numeric Enter Button keys button Wide buttonMenu Screen Space Blinking Character areaArea Display Setup Title Press the FAR buttonRepeat Steps 5 to Menu buttonArea Display Setup Direction EastWest Camera buttonCamera buttonNNumeric keyCamera NumberNENTER button Alarm Title SetupRepeat steps 5 to 7 for each alarm title Auto PAN Setup Set the Auto PAN Mode and Auto PAN SpeedSet the end position only when in the Return mode Select camera. ARM-P2580 AinstructionsbAuto Patrol Setup Change the Auto Patrol modeSet a patroll position Set the length of time a camera will stay in each positionAuto Trace Setup Set the patrol start positionCamera buttonNNumeric key Camera Number Nenter button To Start Auto Trace FunctionPosition Title Setup Select a preset position. a RM-P2580 AinstructionsbRepeat steps 5 to 7 for each title character Position buttonNNumeric key position numberNENTER buttonOther Troubleshooting42 EN Specifications External Dimensions Unit mmPan/Tilt Mechanism GeneralVictor Company of Japan, Limited