16 Connections & Installation (continued)
EN
Cable Connections
CAUTIONS
●Ensure to attach the cover for the ceiling mount. Installation is not possible without attaching the cover.
●The cover prevents penetration of foreign objects into the ceiling mount. Penetration of foreign objects may cause a malfunction or, in the worst scenario, cause smoking or fire.
Connection Procedure
1 Make a hole in the ceiling | 4 Connect the cable to this camera |
Make use of the template supplied to open a hole (R75) for leading the connection cable through the rear side of the ceiling.
2 Remove the Cover
Loosen the Cover Fastening Screw, and turn the Cover in the
MEMO
●When loosening the Cover Fastening Screw, do so while ensuring that it does not protrude from the hole.
Cover Fastening Screw
Cover
Safety Wire
Mounting
Hole
Ceiling Mount (Terminal
Side)
3 Lead the cable through the Cover
Connect cables to the terminal on the ceiling mount. Connection cables include alarm signal cable, coaxial cable, control signal cable and the AC 24 V power cable.
AControl Signal Cable (A pg. 18) For connection to
BCoaxial cable (A pg. 17)
For connection of monitors and other devices.
CAlarm signal cable (A pg. 17)
For connection to devices with alarm input/output terminals.
DPower cable (A pg. 18)
For connection to an AC 24 V power supply. Listed class 2 input only.
A Control Signal Cable
Connect to "To Camera" terminal of RM-
P2580 and to subsequent cameras.
B Coaxial Cable
| Connect to the monitor, etc. |
C Alarm Signal Cable | |
| Connect to devices with |
| alarm input terminal. |
D Power Cable | Connect to AC 24 V power |
supply. Listed class 2 input | |
| only. |
5 Attach the Cover
Attach the Cover to the ceiling mount by following procedure of Step 2 in the reverse order.
A Attach the cover upon aligning the hole with the Safety Wire Mounting Hole on the ceiling mount, followed by turning it in the clockwise direction.
BFasten the Cover Fastening Screw.
Make a slit on the (rubber) cap that is attached to the Cover, followed by leading the cable through. Follow the diagram below to make the slit.
Cap (Upper)