JVC LWT0254-001B-H manual 26 EN, Camera TITLE/ALARM Screen

Page 26

 

 

 

Setting Up the Camera Using RM-P2580 (continued)

 

26 EN

 

 

 

 

 

 

 

 

CAMERA TITLE/ALARM Screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

Function/Set Value

Initial

 

 

 

 

 

 

 

 

 

Value

 

 

 

 

CAM. TITLE EDIT..

 

Use this to specify the title that is always displayed at the bottom left of the screen. Specify

^

 

 

 

 

 

 

up to a maximum of 16 characters. ACAMERA TITLE SetupB (A pg. 34)

 

 

 

 

 

 

 

 

 

 

 

AREA DISPLAY

 

Use this to perform area setting.

 

 

 

 

 

 

 

AAREA DISPLAY Setup (TITLE)B (A pg. 35)

OFF

 

 

 

 

 

 

AAREA DISPLAY Setup (DIRECTION)B (A pg. 36)

 

 

 

 

 

 

 

 

 

 

 

OFF

 

Not displayed.

 

 

 

 

 

 

 

 

 

 

 

TITLE

 

Equally divides the 360° panning range into 16 areas, and a title of up to 16 characters can

 

 

 

 

 

 

 

be specified for each area. The corresponding area title specified will be displayed upon

 

 

 

 

 

 

 

panning the camera manually. AAREA DISPLAY Setup (TITLE)B (A pg. 35)

^

 

 

 

 

 

 

 

 

 

 

DIR

 

Set N (North), which is the direction of the standard axis. When the camera is panned manually,

 

 

 

 

 

 

 

the 360° panning range will be equally divided into 8 areas, each indicated by N, NE, E, SE, S,

 

 

 

 

 

 

 

SW, W and NW respectively. AAREA DISPLAY Setup (DIRECTION)B (A pg. 36)

 

 

 

 

 

 

ALARM TITLE SIZE

 

Use this to set the size of the title during an alarm.

 

 

 

 

 

 

 

NORMAL: Same size as characters on the menu screen.

DOUBLE

 

 

 

 

 

 

DOUBLE: Double the size, both vertically and horizontally, of the characters on the menu screen.

 

 

 

 

 

ALARM TITLE

 

This is a screen for setting the title during an alarm.

^

EDIT..

 

AALARM TITLE SetupB (A pg. 37)

 

 

 

 

 

 

ALARM INPUT..

 

These items are used to perform setting related to the alarm input terminals.

 

 

 

 

 

 

 

 

 

 

 

MODE

 

For selecting the mode of the camera for which images are to be output when there is an alarm input.

 

 

 

 

 

 

 

OFF

: Does not output images even when there is an alarm input.

 

 

 

 

 

 

 

HOME

: Output images at the home position during an alarm input.

 

 

 

 

 

 

 

POS1-99 : Output images at a selected preset position during an alarm input.

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEMO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting the AB&W MODEB (A pg. 27) item to AALARM INB switches the mode to the B&W mode and

 

 

 

 

 

 

 

setting cannot be changed.

 

 

 

 

 

 

 

 

 

 

 

POLARITY

 

For setting the polarity of alarm input signals.

 

 

 

 

 

 

 

MAKE

: Input alarm signals when the contact between each alarm input terminal and the

 

 

 

 

 

 

 

 

GND terminal changes from open to closed.

 

 

 

 

 

 

 

BREAK

: Input alarm signals when the contact between each alarm input terminal and the

MAKE

 

 

 

 

 

 

 

GND terminal changes from closed to open.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEMO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This item will be displayed as "- - -" when the AMODEB item is set to AOFFB and setting is not possible.

 

 

 

 

 

 

 

 

 

 

 

TIME

 

Use this to set the duration of alarm signal output as well as alarm title display when there is

 

 

 

 

 

 

 

an alarm.

 

 

 

 

 

 

 

 

 

[Set values: 5 s, 6 s, 7 s, 8 s, 9 s, 10 s, 15 s, 20 s, 30 s, 60 s]

 

 

 

 

 

 

 

8 CAUTION

 

 

 

 

 

 

 

For RM-P2580 systems, this setting is disabled. Set using the Alarm Time item of RM-

5 s

 

 

 

 

 

 

P2580. (A RM-P2580 AINSTRUCTIONSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

MEMO

 

 

 

 

 

 

 

 

 

This item will be displayed as "- - -" when the AMODEB item is set to AOFFB or when the AB&W MODEB

 

 

 

 

 

 

 

(A pg. 27) item is set to AALARM INB. In both cases, setting will not be possible.

 

 

 

 

 

 

 

 

 

 

 

PRIORITY

 

Sets whether or not manual operation is accepted in case an alarm input is recognized

 

 

 

 

 

 

 

during manual operation of the camera.

 

 

 

 

 

 

 

ALARM

: Manual operation is not accepted when there is an alarm input.

 

 

 

 

 

 

 

 

(Priority given to alarm)

 

 

 

 

 

 

 

MANUAL : Manual operation is accepted even when there is an alarm input.

ALARM

 

 

 

 

 

 

 

(Priority given to manual)

 

 

 

 

 

 

 

8 CAUTION

 

 

 

 

 

 

 

This item is invalid with a system using the RM-P2580. With this system, the ALARM

 

 

 

 

 

 

 

input will permanently override manual operation.

 

 

 

 

 

 

ALARM OUTPUT..

 

Use this to perform setting related to the alarm output terminal.

 

 

 

 

 

 

 

OFF

: Do not output alarm.

 

 

 

 

 

 

 

ALARM

: Output alarm signals when there is an alarm input.

OFF

 

 

 

 

 

 

B&W

: Output alarm signals when the camera switches to the B&W mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESET

: Output alarm signals when the camera moves to a preset position.

 

 

 

 

 

 

 

AUX 1 to AUX 3 : Output alarm signals when there is an auxiliary input.

 

 

 

 

 

 

 

 

 

 

 

Image 26
Contents For Customer Use Model No. TK-C625 Serial No LWT0254-001B-HInformation Safety PrecautionsRisk of Electric Shock Do not Open Important Safeguards Characteristics ContentsOperating Precautions Zooming operation Preset positions→ Refer to Name and Function of Parts Setting Switch Ceiling Mount Setting Switch Side CameraMachine ID Machine ID Setting Switch Auxiliary SwitchConnections & Installation Multi-Drop Communication System110 K Video SWITCHER, etcCAM2 Length of stub CAM32 Length of stub Point-to-Point Communication System ACable ConnectionsB a pg Terminal side of the Ceiling MountSimplex DuplexExample connection with an RM-P2580 Sync Switch SettingsProtocol Machine ID Setting Switch Displayed as ID- LL. CheckMachine ID Installation Remove the Cover Cable ConnectionsMake a hole in the ceiling Connect the cable to this camera Lead the cable through the CoverCable Connecting an RG-59 coaxial cablePolyethylene Mesh Wires Core Wire RatingCable Connect this to the remote control unit RM-P2580Connect to an AC 24 V Supply Within 10 cmFasten the ceiling mount to the ceiling Installing the Ceiling MountAttach the Safety Wire Installing the Camera 20 ENPress and hold the Menu button for 3 seconds Setup ProcedureSetting Up the Camera Using RM-P258021 Press the SET button22 EN Menu Screen ConfigurationSetting Up the Camera Using RM-P2580 Private Mask Mode OFF Camera Function 2 Screen 24 ENCamera Function 1 Screen PAN Limit AF for IRTilt Limit Auto ReturnCamera TITLE/ALARM Screen 26 ENCamera ALC/VIDEO Screen 28 EN Auto PAN/PATROL/TRACE ScreenPOS. Function SET Screen Factory Settings Screen 30 ENPrivate Mask Setup Menu screen display. a pg , steps 2 to Manual PAN Limit SetupSelect a camera. ARM-P2580 Ainstructionsb Set the position for the left limitOperations that override the Manual Pan Limit Settings that override the Manual Pan LimitBasic operation of Manual Pan Limit Right LimitMenu Screen Camera Title SetupTele Numeric Enter Button keys button Wide button Space Blinking Character areaRepeat Steps 5 to Area Display Setup TitlePress the FAR button Menu buttonWest Area Display Setup DirectionEast Camera buttonCamera buttonNNumeric keyCamera NumberNENTER button Alarm Title SetupRepeat steps 5 to 7 for each alarm title Set the end position only when in the Return mode Auto PAN SetupSet the Auto PAN Mode and Auto PAN Speed Select camera. ARM-P2580 AinstructionsbSet a patroll position Auto Patrol SetupChange the Auto Patrol mode Set the length of time a camera will stay in each positionCamera buttonNNumeric key Camera Number Nenter button Auto Trace SetupSet the patrol start position To Start Auto Trace FunctionRepeat steps 5 to 7 for each title character Position Title SetupSelect a preset position. a RM-P2580 Ainstructionsb Position buttonNNumeric key position numberNENTER buttonOther Troubleshooting42 EN Pan/Tilt Mechanism SpecificationsExternal Dimensions Unit mm GeneralVictor Company of Japan, Limited