JVC LWT0254-001B-H manual Area Display Setup Direction, East, West, Camera button

Page 36

36 Setting Up the Camera Using RM-P2580 (continued)

EN

AREA DISPLAY Setup (DIRECTION)

SE

 

SW

East

 

West

E

 

W

 

 

NE

N

NW

 

 

MENU button

 

 

 

 

 

 

 

 

SET button

 

 

 

 

PAN lever

 

 

 

 

 

 

 

 

 

CAMERA button

 

 

 

 

 

 

 

 

 

REMOTE CONTROL UNIT RM-P2580

SETUP

CAMERA

 

 

POSITION

 

 

 

 

POWER

 

 

 

 

 

 

 

MENU

SET

ALARM

 

 

 

AUTO

F-1

F-2

F-3

 

 

KEY LOCK

 

 

 

 

 

 

 

 

LENS

 

CAMERA/POSITION

 

 

PAN/TILT

 

 

SPEED

1

2

3

CAMERA

POSI-

 

 

 

 

 

 

 

 

 

TION

 

 

 

 

IRIS

 

4

5

6

1

2

CLOSE

OPEN

 

 

 

OPTION

OPTION

NEAR

FOCUS

FAR

7

8

9

AUTO

AUTO

 

AF

 

PAN

PATROL

WIDE

ZOOM

TELE

CLEAR

0

ENTER

 

 

 

 

 

 

/HOME

 

 

 

Numeric ENTER

keys button

Upon setting N (North), which is the standard axis, the 360° panning range will be equally divided into 8 areas. Perform manual panning of the camera and each area will be displayed as N, NE, E, SE, S, SW, W, NW.

1Select a camera. (ARM-P2580 AINSTRUCTIONSB)

CAMERA buttonNNumeric key (Camera Number)NENTER button

Video images of the selected camera will be output.

2 Display the MENU screen. (A pg. 21, steps 2 to 4)

MENU button (3 sec.) N Select ACAMERA..B using the PAN lever NSET button.

The AMENUB screen will be displayed.

3 Move the PAN lever upward/downward to shift the cursor (E) to the ACAM. TITLE/ALARM..B item, followed by pressing the

SET button.

The ACAMERA TITLE/ALARMB screen will be displayed.

4 Shift the cursor (E) to the AREA DISPLAY item, and move the PAN lever leftward/rightward to select ADIRB.

5 Press the SET button.

The ADIRECTION STANDARD AXISB screen will be displayed.

6 Move the PAN lever leftward/rightward to set the direction

(N)of the standard axis. 7 Press the MENU button.

This sets the start position of the direction axis, which will be displayed on the top left of the screen.

Directions are displayed as N (north), NE (north-east), E (east), SE (south-east), S (south), SW (south-west), W (west) and NW (north- west) respectively.

MENU

CAM.FUNCTION1..

CAM.FUNCTION2..

CAM.TITLE/ALARM..

CAM.ALC/VIDEO..

AUTO PAN/PATROL/TRACE..

POS.FUNCTION SET..

FACTORY SETTINGS..

<MENU> EXIT <SET> SUB MENU

MENU Screen

CAMERA TITLE / ALARM

CAM.TITLE EDIT..

 

AREA DISPLAY..

DIR

ALARM TITLE SIZE

DOUBLE

ALARM TITLE EDIT..

 

ALARM INPUT..

 

ALARM OUTPUT..

 

<MENU> RETURN <SET> SUB MENU

CAMERA TITLE/ALARM Screen

MEMO

Tilting, zooming and focusing operations are possible when this menu is displayed.

If a start position for the direction axis has already been set, the camera will move to this start position when this menu is invoked.

DIRECTION STANDARD AXIS

SET UP STANDARD AXIS (N)

<MENU> RETURN

DIRECTION STANDARD AXIS Screen

Image 36
Contents For Customer Use Model No. TK-C625 Serial No LWT0254-001B-HSafety Precautions Risk of Electric Shock Do not OpenInformation Important Safeguards Characteristics ContentsOperating Precautions Preset positions → Refer toZooming operation Name and Function of Parts Ceiling Mount Setting Switch Side Camera Machine ID Machine ID Setting SwitchSetting Switch Auxiliary SwitchConnections & Installation Multi-Drop Communication SystemVideo SWITCHER, etc CAM2 Length of stub CAM32 Length of stub110 K Point-to-Point Communication System ACable ConnectionsB a pg Terminal side of the Ceiling MountDuplex Example connection with an RM-P2580Simplex Switch Settings ProtocolSync Machine ID Setting Switch Displayed as ID- LL. CheckMachine ID Installation Cable Connections Make a hole in the ceiling Connect the cable to this cameraRemove the Cover Lead the cable through the CoverConnecting an RG-59 coaxial cable Polyethylene Mesh Wires Core WireCable RatingConnect this to the remote control unit RM-P2580 Connect to an AC 24 V SupplyCable Within 10 cmInstalling the Ceiling Mount Attach the Safety WireFasten the ceiling mount to the ceiling Installing the Camera 20 ENSetup Procedure Setting Up the Camera Using RM-P258021Press and hold the Menu button for 3 seconds Press the SET buttonMenu Screen Configuration Setting Up the Camera Using RM-P258022 EN Private Mask Mode OFF 24 EN Camera Function 1 ScreenCamera Function 2 Screen AF for IR Tilt LimitPAN Limit Auto ReturnCamera TITLE/ALARM Screen 26 ENCamera ALC/VIDEO Screen 28 EN Auto PAN/PATROL/TRACE ScreenPOS. Function SET Screen Factory Settings Screen 30 ENPrivate Mask Setup Manual PAN Limit Setup Select a camera. ARM-P2580 AinstructionsbMenu screen display. a pg , steps 2 to Set the position for the left limitSettings that override the Manual Pan Limit Basic operation of Manual Pan LimitOperations that override the Manual Pan Limit Right LimitCamera Title Setup Tele Numeric Enter Button keys button Wide buttonMenu Screen Space Blinking Character areaArea Display Setup Title Press the FAR buttonRepeat Steps 5 to Menu buttonArea Display Setup Direction EastWest Camera buttonAlarm Title Setup Repeat steps 5 to 7 for each alarm titleCamera buttonNNumeric keyCamera NumberNENTER button Auto PAN Setup Set the Auto PAN Mode and Auto PAN SpeedSet the end position only when in the Return mode Select camera. ARM-P2580 AinstructionsbAuto Patrol Setup Change the Auto Patrol modeSet a patroll position Set the length of time a camera will stay in each positionAuto Trace Setup Set the patrol start positionCamera buttonNNumeric key Camera Number Nenter button To Start Auto Trace FunctionPosition Title Setup Select a preset position. a RM-P2580 AinstructionsbRepeat steps 5 to 7 for each title character Position buttonNNumeric key position numberNENTER buttonTroubleshooting 42 ENOther Specifications External Dimensions Unit mmPan/Tilt Mechanism GeneralVictor Company of Japan, Limited