8Camera

Image pickup device:1/4 type, interline transfer CCD

 

TK-C625E: 752 (H) x 582 (V) pixels

 

TK-C625U: 768 (H) x 494 (V) pixels

Sync system

: Internal, Line Lock

Video output

: VBS 1V (p-p) 75 K

Scanning frequencies : TK-C625E: 15.625 (H), 50 Hz (V)

 

TK-C625U: 15.734 (H), 59.94 Hz (V)

S/N

: 50 dB (typical) (AGC mode: OFF, Enhance

 

level: -5)

Horizontal resolution : 540 lines and above (typical) (WIDE end,

 

 

Centre)

Minimum object illumination :

Color mode

:

3.6 lx (50 % output, AGC 20 dB, WIDE end)

 

 

1.8 lx (25 % output, AGC 20 dB, WIDE end)

B&W mode

:

0.15 lx (50 % output, AGC 20 dB, WIDE

 

 

end)

White balance

: TTL auto tracking/Manual

Electronic shutter :

 

TK-C625E

: 1/50 (standard), 1/120 (60 Hz flickerless),

 

 

1/250, 1/500, 1/1000, 1/2000, 1/4000,

 

 

1/10000

TK-C625U

: 1/60 (standard), 1/100 (50 Hz flickerless),

 

 

1/250, 1/500, 1/1000, 1/2000, 1/4000,

 

 

1/10000

Backlight compensation: Possible, 4 photometry areas selectable

Color level adjustment: Possible

Contour correction: Both horizontal and vertical (level adjustable)

8 Lens

 

Zoom ratio

: Approx. x12

Focal distance

: 3.8 mm to 45.6 mm

Maximum aperture : F1.6 (WIDE) to F2.7 (TELE)

8Pan/Tilt Mechanism

Panning range

: 360° endless revolution

 

Panning speed

: 1.5°/s to 180°/s

 

Tilting range

: 0° to 90° (Horizontal - Straight

 

 

downwards - Horizontal)

 

Tilting speed

: 1°/s to 120°/s

 

8 General

 

 

Power supply

: TK-C625E: AC 24 V, 50 Hz, 1.5 A

 

 

TK-C625U: AC 24 V, 60 Hz, 20 W

 

No. of preset positions : 100

 

Applicable control unit

: RM-P2580

 

Ambient temperature : -10Ito 50I (operating),

 

 

0I to 40I (recommended)

 

Ambient humidity

: 35 % to 90 % RH

 

 

(without condensation)

 

Mass

: 1.3 kg

 

Accessories:

 

 

TK-C625E

: Instructions

2

 

Ceiling Mount

1

 

Template

1

 

Wire Clamp

1

TK-C625U

: Instructions

1

 

Warranty Card

1

 

Service Information Card

1

 

Ceiling Mount

1

 

Template

1

 

Ferrite Core

1

 

Wire Clamp

1

8 External Dimensions [Unit: mm]

8 Ceiling Mount Hole [Unit: mm]

36

Screw

Positions

 

Mounting

127

hole

 

190

 

 

83.5

SR55

120

83.5

1 7

46

Screw Positions

46

70

Specifications and appearance of this unit and related products are

subject to change for product improvement without prior notice.

Image 43
Contents Model No. TK-C625 Serial No LWT0254-001B-H For Customer UseRisk of Electric Shock Do not Open Safety PrecautionsInformation Important Safeguards Contents CharacteristicsOperating Precautions → Refer to Preset positionsZooming operation Name and Function of Parts Auxiliary Switch Ceiling Mount Setting Switch Side CameraMachine ID Machine ID Setting Switch Setting SwitchMulti-Drop Communication System Connections & InstallationCAM2 Length of stub CAM32 Length of stub Video SWITCHER, etc110 K ACable ConnectionsB a pg Terminal side of the Ceiling Mount Point-to-Point Communication SystemExample connection with an RM-P2580 DuplexSimplex Protocol Switch SettingsSync Displayed as ID- LL. Check Machine ID Setting SwitchMachine ID Installation Lead the cable through the Cover Cable ConnectionsMake a hole in the ceiling Connect the cable to this camera Remove the CoverRating Connecting an RG-59 coaxial cablePolyethylene Mesh Wires Core Wire CableWithin 10 cm Connect this to the remote control unit RM-P2580Connect to an AC 24 V Supply CableAttach the Safety Wire Installing the Ceiling MountFasten the ceiling mount to the ceiling 20 EN Installing the CameraPress the SET button Setup ProcedureSetting Up the Camera Using RM-P258021 Press and hold the Menu button for 3 secondsSetting Up the Camera Using RM-P2580 Menu Screen Configuration22 EN Private Mask Mode OFF Camera Function 1 Screen 24 ENCamera Function 2 Screen Auto Return AF for IRTilt Limit PAN Limit26 EN Camera TITLE/ALARM ScreenCamera ALC/VIDEO Screen Auto PAN/PATROL/TRACE Screen 28 ENPOS. Function SET Screen 30 EN Factory Settings ScreenPrivate Mask Setup Set the position for the left limit Manual PAN Limit SetupSelect a camera. ARM-P2580 Ainstructionsb Menu screen display. a pg , steps 2 toRight Limit Settings that override the Manual Pan LimitBasic operation of Manual Pan Limit Operations that override the Manual Pan LimitSpace Blinking Character area Camera Title SetupTele Numeric Enter Button keys button Wide button Menu ScreenMenu button Area Display Setup TitlePress the FAR button Repeat Steps 5 toCamera button Area Display Setup DirectionEast WestRepeat steps 5 to 7 for each alarm title Alarm Title SetupCamera buttonNNumeric keyCamera NumberNENTER button Select camera. ARM-P2580 Ainstructionsb Auto PAN SetupSet the Auto PAN Mode and Auto PAN Speed Set the end position only when in the Return modeSet the length of time a camera will stay in each position Auto Patrol SetupChange the Auto Patrol mode Set a patroll positionTo Start Auto Trace Function Auto Trace SetupSet the patrol start position Camera buttonNNumeric key Camera Number Nenter buttonPosition buttonNNumeric key position numberNENTER button Position Title SetupSelect a preset position. a RM-P2580 Ainstructionsb Repeat steps 5 to 7 for each title character42 EN TroubleshootingOther General SpecificationsExternal Dimensions Unit mm Pan/Tilt MechanismVictor Company of Japan, Limited