Panasonic AG-TL950 appendix Rear Panel

Page 12

2 CONTROLS AND CONNECTORS

2-3 Rear Panel

4

R S - 2 3 2 C

AUDIO

IN

SPARE MIC

OUT

2 3 5

6 8

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

AC~IN

 

 

 

 

 

 

 

 

 

VIDEO

S-VIDEO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAM SW ALARM ALARM COM CLOCK SERIES

 

 

 

 

 

 

 

 

 

 

OUT

IN REC OUT

RESET IN REC IN

 

 

 

 

 

 

 

 

 

 

COM

ALARM

TAPE

WARNING CLOCK SERIES

 

 

 

 

 

 

 

 

 

 

RESET

ENDOUT

OUT RESETOUT REC OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

CAM SW

ALARM ALARM

COM

CLOCK

SERIES

7

9

10

 

 

OUT

IN

REC OUT

 

RESET IN

REC IN

 

 

COM

ALARM

TAPE

WARNING

CLOCK

SERIES

 

 

RESET

ENDOUT

OUT

RESETOUT

REC OUT

1112 13 14 15 16 17 18 19 20 21 22

1[AC IN] connector

Connect to an AC 120 V, 50 Hz/60 Hz socket using the AC mains cable.

2[SPARE] spare connector

This connector is not used now and thus has on function.

3[MIC] mic input connector

Connect a microphone with 3.6-mm dia. plug. When signals are input from both the microphone connector and the audio input connector, audio signals are mixed and recorded.

4[AUDIO IN] audio input connector (Phono)

Receives audio signals from a connected audio source.

5[AUDIO OUT] audio output connector (Phono) Outputs audio signals. No signal is output in the Timelapse Recording/Playback mode.

6[VIDEO IN] video input connector (BNC) Receives composite video signals from a connected camera or other video source.

For composite video signal input, set the <INPUT> menu switch in <VIDEO MODE> to LINE.

7[VIDEO OUT] video output connector (BNC) Outputs composite video signals. Even when the power is not supplied to this unit, input signals (composite video signals) from a camera can be output through this connector (Operating mode-Off Video Throughout function).

8[S-VIDEO IN] S-VIDEO input terminal (4 pin) Inputs separate Y/C signals.

For separate Y/C signal input, set the <IN> menu switch in <VIDEO MODE> to “S-VIDEO”.

9[S-VIDEO OUT] S-VIDEO output terminal (4 pin) Outputs separate Y/C signals.

0Signal ground terminal

This ground terminal is not provided for safety purposes. It is used to ground signals. Connect this terminal to ground the signal between VCRs.

![CAM SW OUT] camera switching signal output terminal

When a sequential switcher is connected, this terminal outputs camera switching timing control signals. For details on these signals, refer to page 56.

@[COM] common ground terminal

Connect to the signal ground terminal of a connected unit.

#[ALARM IN] alarm signal input terminal Receives signals to start alarm or sensor recording.

$[ALARM RESET] alarm signal reset input terminal Receives signals to cancel alarm recording.

*Alarm input data is not reset.

%[ALARM REC OUT] alarm recording mode signal output terminal

Outputs +12 V signals during alarm recording.

12

Image 12
Contents Operating VQT9726Safety Precautions InformationLock indicator Lock button Operation LockTime MODE+/- button Page Contents Major Features IntroductionPeriodical Maintenance PrecautionsIntroduction Inspection procedure Daily InspectionRegarding S-VHS ET Recording Erasure prevention tabControls and Connectors Front PanelControls and Connectors Display Rear Panel Series REC OUT series recording signal output terminal COM common ground terminalConnecting to a Camera ConnectionsSystem Using Sequential Switcher ConnectionsConnecting the Rear Panel Input/Output Terminal Connections ON-SCREEN/MENU Switches Display items On Screen Mode screenOn-Screen Display Changing the on-screen display brightnessON-SCREEN/MENU Switches Contents of the main menu itemsMain Menu Display Date and Time Setting Time setting item and the hour digit blinksSet to OFF Time setting for 29 seconds or less Hour Meter DisplayDuring Daylight Savings time Standard timeAlarm Input/Power Loss Data Display Resetting alarm input/power loss failure dataWith the second item Menu Switch Setting Contents of Menu Switches Screens Items Set values Screens Set values FunctionMode Stop REC T-MODEDuration SEC ContinuePreparation Cassette Loading/UnloadingAuto operate on Auto playRecording/Playback Speed Mode Selection PreparationHigh-Density Recording 120Switch Setting During Recording Menu switch settingsRecording ConnectionRecording Recording Basic OperationTimer Recording Timer Recording Program SettingPreparation RPT Timer recording is executed on the specified day OFF Programmed timer recording is not executedTo program timer recording at another time or day Press the Shift 7 button so that the next settingProgramming timer recording for more than 24 hours Timer button Menu buttonShift 7 button Shift f button Program Timer screen Recording speed On Enabled OFF DisabledStop time Start time Day of the week Holiday Timer Recording Setting T + Timer button Menu button SET button SET + buttonHoliday SET screen MonthDayCanceling/Changing Timer Recording Program To modify timer programsTo stop timer programming before finishing To cancel preset timer programsDuring timer recording Timer recordingIf programmed data overlap If no cassette is loadedAlarm Recording Timelapse Alarm Recording Alarm signal input48H/NORMAL Tape END Mode Setting the alarm buzzerSetting the on-screen brightness and display items Setting the HDRWhen set to AL/SENSOR, both alarm recording Alarm signals are inputSensor Recording Sensor recording will be performedSeries Recording ConnectionsOperation Repeat for all connected VCRsConnection Setting Non-stop continuous series recordingCounter value Second VCR First VCRALARM/SENSOR Mode When the Auto REC Check menu switch is set to onRepeat Recording Operation of the automatic recording check functionRecording with External VCR Activation Signal Alarm search/date and time searchVCR control signal ground signal SRI/EXT Mode screenHow to Restore Recording After Power Failure External Timer RecordingVTR Mode screen Tape End BuzzerMenu switch setting PreparationPlayback To stop playbackPlayback and SPECIAL-EFFECTS Playback Special-Effects PlaybackStill playback Field advance playbackShuttle search reverse and fast-forward playback Fast-forward shuttle search Reverse shuttle searchREW button Play buttonAlarm Search/Date and Time Search Alarm searchAlarm search setting screen Alarm numberAlarm scan Is located, the Stop mode is engagedDate/Time Search mode is canceled Date/time searchCNT Reset button Display button Repeat PlaybackCounter Memory Function Auto rewindTracking/V. Lock Adjustment Lock +/- buttons Tracking +/- buttonsTroubleshooting Error IndicationsError Contents VCR operation Measures Troubleshooting No Error IndicationAppendixes Tape Reel Counter/Tape Remaining Time TableTerminals Signal levels Remarks 2H/6H recording Recording signal inputAppendixes Rear Panel’s Inputs/OutputsSpecifications AlarmTime/date Video SystemSecurity Systems Group Eastern Zone OfficeWestern Zone Office Industrial Medical Group

AG-TL950 specifications

The Panasonic AG-TL950 is a professional-grade broadcast monitor designed to meet the rigorous standards of the film and television industry. This monitor is particularly geared towards production environments that require precision, reliability, and high-quality imaging. With its rich feature set and advanced technologies, the AG-TL950 is a powerful tool for any broadcast or film professional.

One of the standout features of the AG-TL950 is its high-resolution display. The monitor supports 4K resolution, providing crystal-clear image quality and allowing users to see fine details that are critical during production and editing processes. This high resolution, combined with excellent color accuracy, ensures that content creators can trust the colors they are seeing on-screen, which is essential for color grading and post-production work.

The AG-TL950 also employs advanced HDR (High Dynamic Range) technology, which enhances the monitor’s contrast and color range, allowing for a more realistic and immersive viewing experience. This makes it particularly valuable for filmmakers and production teams working on projects that require adherence to modern HDR standards.

Connectivity is another strong suit of the AG-TL950. The monitor is equipped with a variety of input options, including 12G-SDI, HDMI, and both analog and digital audio inputs. This flexibility allows it to integrate smoothly into existing production workflows and ensures compatibility with a wide range of video sources.

In addition to its impressive visual capabilities, the AG-TL950 includes essential features for professional monitoring. It offers waveform and vector scope displays, allowing users to analyze and adjust their signals accurately. Furthermore, the monitor has customizable monitoring options, enabling users to set up to 16 user-defined presets for quick access to their most-used settings.

The design of the AG-TL950 reflects its professional focus, with a robust build quality that speaks to its reliability in dynamic production environments. Its lightweight design makes it easy to transport, while the wide viewing angles ensure that multiple crew members can view the monitor clearly from different positions.

In conclusion, the Panasonic AG-TL950 monitor integrates advanced display technology, versatile connectivity, and user-friendly monitoring features. It stands out as an essential tool for professional filmmakers and broadcast engineers, enabling them to create high-quality visuals with accuracy and confidence.