Panasonic AG-TL950 appendix Controls and Connectors

Page 10

2 CONTROLS AND CONNECTORS

2-1 Front Panel

REC

POWER

STOP

 

 

 

 

 

 

 

POWER

 

 

 

 

HDR

PAUSE/

 

 

 

 

/REW REV PLAY STILL

PLAY FF/

TRACKING

V. LOCK

TIMER SEARCH COUNTER LOCK CNT RESET

 

 

REV ADV

FWD ADV

 

 

 

EJECT

REC REVIEW REC

RESET/

 

 

CANCEL

ON SCREEN

 

 

SHIFT

 

MENU

TIME MODE

 

 

SET

AG-

 

 

26

25 24 23 22 21

20

19

18 17 16 15 14

13

#[RESET/CANCEL] button

In the Timer Program Setting mode, press this button to cancel the program settings. For details, refer to “Timer Recording” on page 36.

Also press this button to interrupt alarm recording or to reset the alarm input data or power loss (power failure) data. For details, refer to pages 21 and 39.

Resets the seconds in the currently displayed time to 00 when pressed together with the $ [CNT RESET] button (except in menu setting mode).

-When the seconds value is 29 or less, the minutes value is the same but the seconds value is reset to 0. (eg. 12:34:29 [ 12:34:00)

-When the seconds value is 30 or more, the seconds value is reset to “00” and the minutes value is increased by one. (e.g. 12:34:30 [12:35:00)

$[CNT RESET] button

When the display shows the control tape counter or reel tape counter, press this button to reset to “00H00M00S” or “0000”.

%[LOCK] button

Press to activate the operation lock function.

^[COUNTER] button

Selects which data — current time, control tape counter (00H 00M 00S — 23H 59M 59S) or reel tape counter (0 — 9999) — is displayed. Each time this button is pressed, the display switches to the next item.

&[SEARCH] button

Use to search the alarm recorded section or a section recorded at a specified date and time. In the Stop mode, select the search mode by pressing this button.

Press once to engage the Alarm Search mode.

Press twice to engage the Alarm Scan mode.

Press three times to engage the Date/Time Search mode.

Press four times to release the search mode.

After the search mode is selected with this button, press the [FF] or [REW] button to execute the search operation in the selected mode.

For details, refer to page 49.

*[TIMER] button

Normally use this button for timer recording. For details, refer to “Timer Recording” on page 31.

([V. LOCK +/–] buttons

Press to reduce vertical picture jitter in the Still, Field Advance Playback and Linear Slow Timelapse Play modes.

)[TRACKING +/–] buttons

If picture noise appears during play or field advance, press these buttons to adjust tracking so that noise is reduced. When the [+] and [–] buttons are pressed simultaneously, tracking is reset to the preset level.

*You cannot make any tracking adjustment at L12H and L24H Linear Slow Time-lapse Playback modes.

q[FF] button

Press to fast-forward the tape.

Starts fast-forward search when pressed in the Play mode.

Starts forward alarm search or date/time search when the Search mode is specified with the & [SEARCH] button.

Also controls field-by-field playback in the forward direction.

w[PLAY] button

• Press to play back the tape.

e[PAUSE/STILL] button

Engages the Record-Pause mode when pressed in the Record mode.

Displays a still picture when pressed in the Play mode.

Field advance or reverse playback is executed each time the [FF] or [REW] button is pressed while pressing this button in the Still mode. (When the [FF] or [REW] button is pressed for more than 2 seconds, Continuous Field Advance Playback mode is engaged. After about 3 minutes, the Stop mode is engaged.)

r[REV PLAY] button

Starts reverse playback when pressed in any mode except Record, Record-Pause and Record Check.

t[REW] button

Press this button to rewind the cassette.

Starts rewind search when pressed in the Play mode.

Starts reverse alarm search or date/time search when the Search mode is specified with the & [SEARCH] button.

Also controls field-by-field playback in the reverse direction.

y[HDR] indicator

Lights in the HDR recording and HDR playback modes.

* HDR: High Density Recording

• For details on HDR recording, refer to page 28.

10

Image 10
Contents Operating VQT9726Safety Precautions InformationOperation Lock Lock indicator Lock buttonTime MODE+/- button Page Contents Major Features IntroductionPrecautions Periodical MaintenanceIntroduction Regarding S-VHS ET Recording Inspection procedureDaily Inspection Erasure prevention tabControls and Connectors Front PanelControls and Connectors Display Rear Panel Series REC OUT series recording signal output terminal COM common ground terminalConnecting to a Camera ConnectionsSystem Using Sequential Switcher ConnectionsConnecting the Rear Panel Input/Output Terminal Connections On-Screen Display ON-SCREEN/MENU SwitchesDisplay items On Screen Mode screen Changing the on-screen display brightnessContents of the main menu items ON-SCREEN/MENU SwitchesMain Menu Display Time setting item and the hour digit blinks Date and Time SettingSet to OFF During Daylight Savings time Time setting for 29 seconds or lessHour Meter Display Standard timeResetting alarm input/power loss failure data Alarm Input/Power Loss Data DisplayWith the second item Menu Switch Setting Contents of Menu Switches Screens Items Set values Screens Set values FunctionDuration SEC Mode StopREC T-MODE ContinueAuto operate on PreparationCassette Loading/Unloading Auto playHigh-Density Recording Recording/Playback Speed Mode SelectionPreparation 120Recording Switch Setting During RecordingMenu switch settings ConnectionRecording Recording Basic OperationTimer Recording Program Setting Timer RecordingPreparation To program timer recording at another time or day RPT Timer recording is executed on the specified dayOFF Programmed timer recording is not executed Press the Shift 7 button so that the next settingTimer button Menu button Programming timer recording for more than 24 hoursShift 7 button Shift f button On Enabled OFF Disabled Program Timer screen Recording speedStop time Start time Day of the week Holiday SET screen Holiday Timer Recording SettingT + Timer button Menu button SET button SET + button MonthDayTo stop timer programming before finishing Canceling/Changing Timer Recording ProgramTo modify timer programs To cancel preset timer programsIf programmed data overlap During timer recordingTimer recording If no cassette is loadedTimelapse Alarm Recording Alarm signal input Alarm Recording48H/NORMAL Setting the on-screen brightness and display items Tape END ModeSetting the alarm buzzer Setting the HDRSensor Recording When set to AL/SENSOR, both alarm recordingAlarm signals are input Sensor recording will be performedOperation Series RecordingConnections Repeat for all connected VCRsCounter value Connection SettingNon-stop continuous series recording Second VCR First VCRRepeat Recording ALARM/SENSOR ModeWhen the Auto REC Check menu switch is set to on Operation of the automatic recording check functionVCR control signal ground signal Recording with External VCR Activation SignalAlarm search/date and time search SRI/EXT Mode screenVTR Mode screen How to Restore Recording After Power FailureExternal Timer Recording Tape End BuzzerPlayback Menu switch settingPreparation To stop playbackStill playback Playback and SPECIAL-EFFECTS PlaybackSpecial-Effects Playback Field advance playbackREW button Shuttle search reverse and fast-forward playbackFast-forward shuttle search Reverse shuttle search Play buttonAlarm search setting screen Alarm Search/Date and Time SearchAlarm search Alarm numberDate/Time Search mode is canceled Alarm scanIs located, the Stop mode is engaged Date/time searchCounter Memory Function CNT Reset button Display buttonRepeat Playback Auto rewindTracking/V. Lock Adjustment Lock +/- buttons Tracking +/- buttonsError Indications TroubleshootingError Contents VCR operation Measures Troubleshooting No Error IndicationAppendixes Tape Reel Counter/Tape Remaining Time TableAppendixes Terminals Signal levels Remarks 2H/6H recordingRecording signal input Rear Panel’s Inputs/OutputsTime/date SpecificationsAlarm Video SystemWestern Zone Office Security Systems GroupEastern Zone Office Industrial Medical Group

AG-TL950 specifications

The Panasonic AG-TL950 is a professional-grade broadcast monitor designed to meet the rigorous standards of the film and television industry. This monitor is particularly geared towards production environments that require precision, reliability, and high-quality imaging. With its rich feature set and advanced technologies, the AG-TL950 is a powerful tool for any broadcast or film professional.

One of the standout features of the AG-TL950 is its high-resolution display. The monitor supports 4K resolution, providing crystal-clear image quality and allowing users to see fine details that are critical during production and editing processes. This high resolution, combined with excellent color accuracy, ensures that content creators can trust the colors they are seeing on-screen, which is essential for color grading and post-production work.

The AG-TL950 also employs advanced HDR (High Dynamic Range) technology, which enhances the monitor’s contrast and color range, allowing for a more realistic and immersive viewing experience. This makes it particularly valuable for filmmakers and production teams working on projects that require adherence to modern HDR standards.

Connectivity is another strong suit of the AG-TL950. The monitor is equipped with a variety of input options, including 12G-SDI, HDMI, and both analog and digital audio inputs. This flexibility allows it to integrate smoothly into existing production workflows and ensures compatibility with a wide range of video sources.

In addition to its impressive visual capabilities, the AG-TL950 includes essential features for professional monitoring. It offers waveform and vector scope displays, allowing users to analyze and adjust their signals accurately. Furthermore, the monitor has customizable monitoring options, enabling users to set up to 16 user-defined presets for quick access to their most-used settings.

The design of the AG-TL950 reflects its professional focus, with a robust build quality that speaks to its reliability in dynamic production environments. Its lightweight design makes it easy to transport, while the wide viewing angles ensure that multiple crew members can view the monitor clearly from different positions.

In conclusion, the Panasonic AG-TL950 monitor integrates advanced display technology, versatile connectivity, and user-friendly monitoring features. It stands out as an essential tool for professional filmmakers and broadcast engineers, enabling them to create high-quality visuals with accuracy and confidence.