Panasonic AG-TL950 ON-SCREEN/MENU Switches, Main Menu Display, Contents of the main menu items

Page 18

4 ON-SCREEN/MENU SWITCHES

4-2 Main Menu Display

You can display date and time data recorded when an alarm input or power failure occurs, as well as the hour meter (drum rotating time) by selecting the desired item in the main menu.

The date/time setting screen, menu switch setting screen for each application, and timer recording program setting screen can also be displayed by selecting the desired item in the main menu.

Date/time setting, menu switch setting and hour meter can be checked on the VCR’s display as well.

[SHIFT 7] button

[SHIFT t] button

 

 

 

REC

 

EJECT

 

 

POWER

 

REC REVIEW

REC

HDR

RESET/

ON SCREEN

 

 

CANCEL

 

CNT RESET

 

SHIFT

MENU

TIME MODE

SET

[MENU] button

[SET +] button

 

[SET –] button

 

 

Main menu screen

*

* * * * * * [ MENU ] * * * * * * * * * * *

* T I ME AD J US T * * * * * * * * * * * *

*

ONSCREEN / F . D I SP * MODE * * *

*

V I DEO / V TR * MODE * * * * * * * * *

*

SR I / EX T * MODE * * * * * * * * * * *

*

ALARM / SENSOR * MODE * * ONNN

*

BUZ Z ER / I N * OUT * * * * * * ONNN

*

PROGRAM * T I MER * * * * * * * * * *

*

HOL I DAY * SE T * * * * * * * * * * * *

*

HOUR

ME T ER * * * * * * * * * ONNN

*

ALARM * RECAL L / POWER * LOSS

*

 

 

AG-

Cursor

Contents of the main menu items

5TIME ADJUST (VCR's displayT ADJ) Displays the date/time setting screen.

*Set the clock before operating the VCR (refer to page 19).

5ONSCREEN/FRONT DISPLAY MODE (VCR's displayDiSP)

Let’s you choose whether or not to display on- screen display items, brightness selection, [REC] indicator and warning indicator.

5VIDEO/VTR MODE (VCR's displayViDEO)

For VCR operation settings such as V. Pulse ON/ OFF, HDR recording, counter memory function and repeat recording/playback.

5 SRI/EXT MODE (VCR's displaySRi ET)

For setting series recording or automatic recording with an external signal.

5ALARM/SENSOR MODE (VCR's displayAL 5EN) For setting alarm recording or sensor recording operation.

Operation

5Connect the video output connector of this unit to the monitor’s video input connector.

1Turn on the monitor and VCR.

2Press the [MENU] button.

[ The main menu screen is shown on the monitor screen.

3Press the [SHIFT 7] button to move the cursor to the item you want to display.

4Press the [SET +/–] button to display the selected menu screen on the monitor (see below).

5To restore the main menu screen, press the [MENU] button.

To cancel the main menu mode, press the [MENU] button again. The normal screen is restored.

5BUZZER/IN OUT (VCR's displayBU22iO)

Turn ON/OFF buzzers such as the tape end buzzer and alarm/sensor buzzer and set camera switch signal output.

5PROGRAM TIMER (VCR's displayPRG)

Shows timer recording program settings with the day of the week.

5HOLIDAY SET (VCR's displayHOLiDY)

Shows timer recording program settings at specified dates.

5HOUR METER (VCR's displayHOUR)

Shows the VCR’s operating time (drum rotation time).

5ALARM RECALL/POWER LOSS (VCR's displayAL P0)

Shows the date and time when an alarm was input or a power failure occurred.

18

Image 18
Contents Operating VQT9726Safety Precautions InformationLock indicator Lock button Operation LockTime MODE+/- button Page Contents Major Features IntroductionPeriodical Maintenance PrecautionsIntroduction Regarding S-VHS ET Recording Inspection procedureDaily Inspection Erasure prevention tabControls and Connectors Front PanelControls and Connectors Display Rear Panel Series REC OUT series recording signal output terminal COM common ground terminalConnecting to a Camera ConnectionsSystem Using Sequential Switcher ConnectionsConnecting the Rear Panel Input/Output Terminal Connections On-Screen Display ON-SCREEN/MENU SwitchesDisplay items On Screen Mode screen Changing the on-screen display brightnessON-SCREEN/MENU Switches Contents of the main menu itemsMain Menu Display Date and Time Setting Time setting item and the hour digit blinksSet to OFF During Daylight Savings time Time setting for 29 seconds or lessHour Meter Display Standard timeAlarm Input/Power Loss Data Display Resetting alarm input/power loss failure dataWith the second item Menu Switch Setting Contents of Menu Switches Screens Items Set values Screens Set values FunctionDuration SEC Mode StopREC T-MODE ContinueAuto operate on PreparationCassette Loading/Unloading Auto playHigh-Density Recording Recording/Playback Speed Mode SelectionPreparation 120Recording Switch Setting During RecordingMenu switch settings ConnectionRecording Recording Basic OperationTimer Recording Timer Recording Program SettingPreparation To program timer recording at another time or day RPT Timer recording is executed on the specified dayOFF Programmed timer recording is not executed Press the Shift 7 button so that the next settingProgramming timer recording for more than 24 hours Timer button Menu buttonShift 7 button Shift f button Program Timer screen Recording speed On Enabled OFF DisabledStop time Start time Day of the week Holiday SET screen Holiday Timer Recording SettingT + Timer button Menu button SET button SET + button MonthDayTo stop timer programming before finishing Canceling/Changing Timer Recording ProgramTo modify timer programs To cancel preset timer programsIf programmed data overlap During timer recordingTimer recording If no cassette is loadedAlarm Recording Timelapse Alarm Recording Alarm signal input48H/NORMAL Setting the on-screen brightness and display items Tape END ModeSetting the alarm buzzer Setting the HDRSensor Recording When set to AL/SENSOR, both alarm recordingAlarm signals are input Sensor recording will be performedOperation Series RecordingConnections Repeat for all connected VCRsCounter value Connection SettingNon-stop continuous series recording Second VCR First VCRRepeat Recording ALARM/SENSOR ModeWhen the Auto REC Check menu switch is set to on Operation of the automatic recording check functionVCR control signal ground signal Recording with External VCR Activation SignalAlarm search/date and time search SRI/EXT Mode screenVTR Mode screen How to Restore Recording After Power FailureExternal Timer Recording Tape End BuzzerPlayback Menu switch settingPreparation To stop playbackStill playback Playback and SPECIAL-EFFECTS PlaybackSpecial-Effects Playback Field advance playbackREW button Shuttle search reverse and fast-forward playbackFast-forward shuttle search Reverse shuttle search Play buttonAlarm search setting screen Alarm Search/Date and Time SearchAlarm search Alarm numberDate/Time Search mode is canceled Alarm scanIs located, the Stop mode is engaged Date/time searchCounter Memory Function CNT Reset button Display buttonRepeat Playback Auto rewindTracking/V. Lock Adjustment Lock +/- buttons Tracking +/- buttonsTroubleshooting Error IndicationsError Contents VCR operation Measures Troubleshooting No Error IndicationAppendixes Tape Reel Counter/Tape Remaining Time TableAppendixes Terminals Signal levels Remarks 2H/6H recordingRecording signal input Rear Panel’s Inputs/OutputsTime/date SpecificationsAlarm Video SystemWestern Zone Office Security Systems GroupEastern Zone Office Industrial Medical Group

AG-TL950 specifications

The Panasonic AG-TL950 is a professional-grade broadcast monitor designed to meet the rigorous standards of the film and television industry. This monitor is particularly geared towards production environments that require precision, reliability, and high-quality imaging. With its rich feature set and advanced technologies, the AG-TL950 is a powerful tool for any broadcast or film professional.

One of the standout features of the AG-TL950 is its high-resolution display. The monitor supports 4K resolution, providing crystal-clear image quality and allowing users to see fine details that are critical during production and editing processes. This high resolution, combined with excellent color accuracy, ensures that content creators can trust the colors they are seeing on-screen, which is essential for color grading and post-production work.

The AG-TL950 also employs advanced HDR (High Dynamic Range) technology, which enhances the monitor’s contrast and color range, allowing for a more realistic and immersive viewing experience. This makes it particularly valuable for filmmakers and production teams working on projects that require adherence to modern HDR standards.

Connectivity is another strong suit of the AG-TL950. The monitor is equipped with a variety of input options, including 12G-SDI, HDMI, and both analog and digital audio inputs. This flexibility allows it to integrate smoothly into existing production workflows and ensures compatibility with a wide range of video sources.

In addition to its impressive visual capabilities, the AG-TL950 includes essential features for professional monitoring. It offers waveform and vector scope displays, allowing users to analyze and adjust their signals accurately. Furthermore, the monitor has customizable monitoring options, enabling users to set up to 16 user-defined presets for quick access to their most-used settings.

The design of the AG-TL950 reflects its professional focus, with a robust build quality that speaks to its reliability in dynamic production environments. Its lightweight design makes it easy to transport, while the wide viewing angles ensure that multiple crew members can view the monitor clearly from different positions.

In conclusion, the Panasonic AG-TL950 monitor integrates advanced display technology, versatile connectivity, and user-friendly monitoring features. It stands out as an essential tool for professional filmmakers and broadcast engineers, enabling them to create high-quality visuals with accuracy and confidence.