Panasonic AG-TL950 appendix Connecting the Rear Panel Input/Output Terminal Connections

Page 16

3 CONNECTIONS

3-3 Connecting the Rear Panel Input/Output Terminal Connections

[CAM SW OUT] camera switching signal output terminal

 

[ALARM IN] alarm signal input terminal

CAM SW

 

ALARM

 

IN COM

OUT COM

 

 

 

Sequential switcher

camera switching signal input

Sequential switcher alarm output terminal

[ALARM RESET] alarm reset terminal

 

[ALARM REC OUT] alarm recording mode signal output terminal

 

 

 

ALARM

RESET COM

Vcc

Switch

Vcc: 5V–12V

ALARMALARM

RESET

REC OUT COM

Switch

Alarm lamp

External interface

[TAPE END OUT] tape end output terminal

 

[WARNING OUT] warning signal output terminal

 

 

 

WARNING

TAPE

END OUT COM

OUT COM

Alarm lamp

External interface

[CLOCK RESET] clock reset terminal

5When setting the clock to the first VCR’s clock

First VCR

 

Second VCR

 

Last VCR

Alarm lamp

External interface

CLOCK

 

CLOCK

 

CLOCK

External interface example

 

 

 

OUT

COM

IN

COM

IN

COM

 

 

 

 

 

Example: Lamp lights with HIGH signal

5When setting the clock to the external master clock

 

 

First VCR

 

Second VCR

External

 

CLOCK

 

 

CLOCK

 

master clock

 

IN

COM

IN

COM

 

 

 

 

 

 

 

 

 

 

Power

 

supply

Last VCR

Control

signal

 

CLOCK

GND

IN

COM

(Lamp, etc.)

Relay

5Use appropriately rated devices.

16

Image 16
Contents Operating VQT9726Safety Precautions InformationOperation Lock Lock indicator Lock buttonTime MODE+/- button Page Contents Major Features IntroductionPrecautions Periodical MaintenanceIntroduction Inspection procedure Daily InspectionRegarding S-VHS ET Recording Erasure prevention tabControls and Connectors Front PanelControls and Connectors Display Rear Panel Series REC OUT series recording signal output terminal COM common ground terminalConnecting to a Camera ConnectionsSystem Using Sequential Switcher ConnectionsConnecting the Rear Panel Input/Output Terminal Connections ON-SCREEN/MENU Switches Display items On Screen Mode screenOn-Screen Display Changing the on-screen display brightnessContents of the main menu items ON-SCREEN/MENU SwitchesMain Menu Display Time setting item and the hour digit blinks Date and Time SettingSet to OFF Time setting for 29 seconds or less Hour Meter DisplayDuring Daylight Savings time Standard timeResetting alarm input/power loss failure data Alarm Input/Power Loss Data DisplayWith the second item Menu Switch Setting Contents of Menu Switches Screens Items Set values Screens Set values FunctionMode Stop REC T-MODEDuration SEC ContinuePreparation Cassette Loading/UnloadingAuto operate on Auto playRecording/Playback Speed Mode Selection PreparationHigh-Density Recording 120Switch Setting During Recording Menu switch settingsRecording ConnectionRecording Recording Basic OperationTimer Recording Program Setting Timer RecordingPreparation RPT Timer recording is executed on the specified day OFF Programmed timer recording is not executedTo program timer recording at another time or day Press the Shift 7 button so that the next settingTimer button Menu button Programming timer recording for more than 24 hoursShift 7 button Shift f button On Enabled OFF Disabled Program Timer screen Recording speedStop time Start time Day of the week Holiday Timer Recording Setting T + Timer button Menu button SET button SET + buttonHoliday SET screen MonthDayCanceling/Changing Timer Recording Program To modify timer programsTo stop timer programming before finishing To cancel preset timer programsDuring timer recording Timer recordingIf programmed data overlap If no cassette is loadedTimelapse Alarm Recording Alarm signal input Alarm Recording48H/NORMAL Tape END Mode Setting the alarm buzzerSetting the on-screen brightness and display items Setting the HDRWhen set to AL/SENSOR, both alarm recording Alarm signals are inputSensor Recording Sensor recording will be performedSeries Recording ConnectionsOperation Repeat for all connected VCRsConnection Setting Non-stop continuous series recordingCounter value Second VCR First VCRALARM/SENSOR Mode When the Auto REC Check menu switch is set to onRepeat Recording Operation of the automatic recording check functionRecording with External VCR Activation Signal Alarm search/date and time searchVCR control signal ground signal SRI/EXT Mode screenHow to Restore Recording After Power Failure External Timer RecordingVTR Mode screen Tape End BuzzerMenu switch setting PreparationPlayback To stop playbackPlayback and SPECIAL-EFFECTS Playback Special-Effects PlaybackStill playback Field advance playbackShuttle search reverse and fast-forward playback Fast-forward shuttle search Reverse shuttle searchREW button Play buttonAlarm Search/Date and Time Search Alarm searchAlarm search setting screen Alarm numberAlarm scan Is located, the Stop mode is engagedDate/Time Search mode is canceled Date/time searchCNT Reset button Display button Repeat PlaybackCounter Memory Function Auto rewindTracking/V. Lock Adjustment Lock +/- buttons Tracking +/- buttonsError Indications TroubleshootingError Contents VCR operation Measures Troubleshooting No Error IndicationAppendixes Tape Reel Counter/Tape Remaining Time TableTerminals Signal levels Remarks 2H/6H recording Recording signal inputAppendixes Rear Panel’s Inputs/OutputsSpecifications AlarmTime/date Video SystemSecurity Systems Group Eastern Zone OfficeWestern Zone Office Industrial Medical Group

AG-TL950 specifications

The Panasonic AG-TL950 is a professional-grade broadcast monitor designed to meet the rigorous standards of the film and television industry. This monitor is particularly geared towards production environments that require precision, reliability, and high-quality imaging. With its rich feature set and advanced technologies, the AG-TL950 is a powerful tool for any broadcast or film professional.

One of the standout features of the AG-TL950 is its high-resolution display. The monitor supports 4K resolution, providing crystal-clear image quality and allowing users to see fine details that are critical during production and editing processes. This high resolution, combined with excellent color accuracy, ensures that content creators can trust the colors they are seeing on-screen, which is essential for color grading and post-production work.

The AG-TL950 also employs advanced HDR (High Dynamic Range) technology, which enhances the monitor’s contrast and color range, allowing for a more realistic and immersive viewing experience. This makes it particularly valuable for filmmakers and production teams working on projects that require adherence to modern HDR standards.

Connectivity is another strong suit of the AG-TL950. The monitor is equipped with a variety of input options, including 12G-SDI, HDMI, and both analog and digital audio inputs. This flexibility allows it to integrate smoothly into existing production workflows and ensures compatibility with a wide range of video sources.

In addition to its impressive visual capabilities, the AG-TL950 includes essential features for professional monitoring. It offers waveform and vector scope displays, allowing users to analyze and adjust their signals accurately. Furthermore, the monitor has customizable monitoring options, enabling users to set up to 16 user-defined presets for quick access to their most-used settings.

The design of the AG-TL950 reflects its professional focus, with a robust build quality that speaks to its reliability in dynamic production environments. Its lightweight design makes it easy to transport, while the wide viewing angles ensure that multiple crew members can view the monitor clearly from different positions.

In conclusion, the Panasonic AG-TL950 monitor integrates advanced display technology, versatile connectivity, and user-friendly monitoring features. It stands out as an essential tool for professional filmmakers and broadcast engineers, enabling them to create high-quality visuals with accuracy and confidence.