Panasonic AG-TL950 appendix 48H/NORMAL, Timelapse Alarm Recording Alarm signal input

Page 38

6 RECORDING

6-4 Alarm Recording

Alarm recording functions during timelapse recording. When an alarm signal is input to the rear panel’s ALARM IN terminal, an index code is recorded on the tape and the VCR automatically switches to the 2H/6H/L12H/L18H/L24H/24H/48H/NORMAL mode for realtime recording of the alarm situation. Normal timelapse recording is restored after the preset alarm recording duration has passed.

* Alarm recording will not start from the Pause mode.

 

 

 

 

 

 

 

REC

POWER

STOP

 

 

 

EJECT

 

 

 

 

 

 

POWER

 

REC REVIEW

REC

 

 

 

 

HDR

RESET/

 

 

 

 

ON SCREEN

 

 

 

 

 

 

CANCEL

 

PAUSE/

PLAY FF/

 

 

 

 

SHIFT

 

/REW REV PLAY STILL

TRACKING

V. LOCK

TIMER SEARCH COUNTER LOCK CNT RESET

MENU

TIME MODE

 

REV ADV

FWD ADV

 

 

 

 

SET

AG-

“AL” indication

AL

TIME MODE

5Menu switches are provided for alarm recording mode, alarm recording duration, buzzer ON/OFF in alarm recording, and Forced Stop mode ON/OFF at tape end.

5During alarm recording, the [AL] indication is lit on the VCR and the [ALARM] indication is lit on the monitor display. After alarm recording is complete, the “AL” indication blinks on the display to show that an alarm signal has been input.

*If the alarm recording function is activated a hundred times a day or more, a malfunction may occur because the guaranteed range is exceeded.

If you want to use this unit more than a hundred times a day, set the recording speed mode to 2H/6H and perform regular maintenance, replacing parts as necessary.

On-screen

 

 

 

 

 

 

"ALARM"

Extinguished

Shown

Extinguished

Shown

Extinguished

 

indication

 

 

 

 

 

 

 

 

 

 

 

 

 

Display "AL"

Extinguished

Lit

Blinking

Lit

Blinking

 

indication

 

 

 

 

 

 

 

 

Record mode

Timelapse

2H/6H/L12H/

Timelapse

2H/6H/L12H/

Timelapse

 

mode

L18H/L24H/24H/

mode

L18H/L24H/24H/

mode

 

 

 

 

 

48H/NORMAL

 

48H/NORMAL

 

 

 

 

 

 

 

 

 

 

Timelapse

Alarm

Timelapse

Alarm

Timelapse

 

 

recording

recording

recording

recording

recording

 

Alarm signal input

Alarm signal input

*An index code (VISS) is recorded at the start point of the alarm recording as an alarm cue signal.

*During alarm recording, a +12 V signal is output from the rear panel’s ALARM REC OUT terminal.

*If a new alarm signal is input during alarm recording, alarm recording restarts from that point.

38

Image 38
Contents Operating VQT9726Safety Precautions InformationTime MODE+/- button Lock indicator Lock buttonOperation Lock Page Contents Major Features IntroductionIntroduction Periodical MaintenancePrecautions Regarding S-VHS ET Recording Inspection procedureDaily Inspection Erasure prevention tabControls and Connectors Front PanelControls and Connectors Display Rear Panel Series REC OUT series recording signal output terminal COM common ground terminalConnecting to a Camera ConnectionsSystem Using Sequential Switcher ConnectionsConnecting the Rear Panel Input/Output Terminal Connections On-Screen Display ON-SCREEN/MENU SwitchesDisplay items On Screen Mode screen Changing the on-screen display brightnessMain Menu Display ON-SCREEN/MENU SwitchesContents of the main menu items Set to OFF Date and Time SettingTime setting item and the hour digit blinks During Daylight Savings time Time setting for 29 seconds or lessHour Meter Display Standard timeWith the second item Alarm Input/Power Loss Data DisplayResetting alarm input/power loss failure data Menu Switch Setting Contents of Menu Switches Screens Items Set values Screens Set values FunctionDuration SEC Mode StopREC T-MODE ContinueAuto operate on PreparationCassette Loading/Unloading Auto playHigh-Density Recording Recording/Playback Speed Mode SelectionPreparation 120Recording Switch Setting During RecordingMenu switch settings ConnectionRecording Recording Basic OperationPreparation Timer RecordingTimer Recording Program Setting To program timer recording at another time or day RPT Timer recording is executed on the specified dayOFF Programmed timer recording is not executed Press the Shift 7 button so that the next settingShift 7 button Shift f button Programming timer recording for more than 24 hoursTimer button Menu button Stop time Start time Day of the week Program Timer screen Recording speedOn Enabled OFF Disabled Holiday SET screen Holiday Timer Recording SettingT + Timer button Menu button SET button SET + button MonthDayTo stop timer programming before finishing Canceling/Changing Timer Recording ProgramTo modify timer programs To cancel preset timer programsIf programmed data overlap During timer recordingTimer recording If no cassette is loaded48H/NORMAL Alarm RecordingTimelapse Alarm Recording Alarm signal input Setting the on-screen brightness and display items Tape END ModeSetting the alarm buzzer Setting the HDRSensor Recording When set to AL/SENSOR, both alarm recordingAlarm signals are input Sensor recording will be performedOperation Series RecordingConnections Repeat for all connected VCRsCounter value Connection SettingNon-stop continuous series recording Second VCR First VCRRepeat Recording ALARM/SENSOR ModeWhen the Auto REC Check menu switch is set to on Operation of the automatic recording check functionVCR control signal ground signal Recording with External VCR Activation SignalAlarm search/date and time search SRI/EXT Mode screenVTR Mode screen How to Restore Recording After Power FailureExternal Timer Recording Tape End BuzzerPlayback Menu switch settingPreparation To stop playbackStill playback Playback and SPECIAL-EFFECTS PlaybackSpecial-Effects Playback Field advance playbackREW button Shuttle search reverse and fast-forward playbackFast-forward shuttle search Reverse shuttle search Play buttonAlarm search setting screen Alarm Search/Date and Time SearchAlarm search Alarm numberDate/Time Search mode is canceled Alarm scanIs located, the Stop mode is engaged Date/time searchCounter Memory Function CNT Reset button Display buttonRepeat Playback Auto rewindTracking/V. Lock Adjustment Lock +/- buttons Tracking +/- buttonsError Contents VCR operation Measures TroubleshootingError Indications Troubleshooting No Error IndicationAppendixes Tape Reel Counter/Tape Remaining Time TableAppendixes Terminals Signal levels Remarks 2H/6H recordingRecording signal input Rear Panel’s Inputs/OutputsTime/date SpecificationsAlarm Video SystemWestern Zone Office Security Systems GroupEastern Zone Office Industrial Medical Group

AG-TL950 specifications

The Panasonic AG-TL950 is a professional-grade broadcast monitor designed to meet the rigorous standards of the film and television industry. This monitor is particularly geared towards production environments that require precision, reliability, and high-quality imaging. With its rich feature set and advanced technologies, the AG-TL950 is a powerful tool for any broadcast or film professional.

One of the standout features of the AG-TL950 is its high-resolution display. The monitor supports 4K resolution, providing crystal-clear image quality and allowing users to see fine details that are critical during production and editing processes. This high resolution, combined with excellent color accuracy, ensures that content creators can trust the colors they are seeing on-screen, which is essential for color grading and post-production work.

The AG-TL950 also employs advanced HDR (High Dynamic Range) technology, which enhances the monitor’s contrast and color range, allowing for a more realistic and immersive viewing experience. This makes it particularly valuable for filmmakers and production teams working on projects that require adherence to modern HDR standards.

Connectivity is another strong suit of the AG-TL950. The monitor is equipped with a variety of input options, including 12G-SDI, HDMI, and both analog and digital audio inputs. This flexibility allows it to integrate smoothly into existing production workflows and ensures compatibility with a wide range of video sources.

In addition to its impressive visual capabilities, the AG-TL950 includes essential features for professional monitoring. It offers waveform and vector scope displays, allowing users to analyze and adjust their signals accurately. Furthermore, the monitor has customizable monitoring options, enabling users to set up to 16 user-defined presets for quick access to their most-used settings.

The design of the AG-TL950 reflects its professional focus, with a robust build quality that speaks to its reliability in dynamic production environments. Its lightweight design makes it easy to transport, while the wide viewing angles ensure that multiple crew members can view the monitor clearly from different positions.

In conclusion, the Panasonic AG-TL950 monitor integrates advanced display technology, versatile connectivity, and user-friendly monitoring features. It stands out as an essential tool for professional filmmakers and broadcast engineers, enabling them to create high-quality visuals with accuracy and confidence.