6 RECORDING

6-4 Alarm Recording

Preparation

Connect an alarm sensor to the rear panel’s alarm input terminal.

1Press the [POWER] button to turn the operating mode on.

2Open the main menu’s <ALARM/SENSOR MODE> and set the alarm recording-related menu switches.

1 REC MODE

Set to “ALARM” or “AL/SENSOR” to activate alarm recording.

When set to “AL/SENSOR”, both alarm recording and sensor recording will be performed.

The [ALARM] indication lights on the display.

2DURATION

Set the alarm recording duration to 5 sec., 10 sec., 15 sec., 30 sec., 60 sec., 120 sec., 180 sec., COUNTINUE (to tape end) or MANUAL (for as long as alarm signals are input).

*When the alarm recording time is set to “MANUAL”, the alarm cue signal (index code) will not be recorded correctly if alarm input lasts for less than 5 seconds.

*When alarm recording duration is set with an external switcher, set the alarm recording duration to “MANUAL”.

3TAPE END MODE

Selects whether or not the Stop mode is forcibly engaged when the tape ends even if there is an alarm recording during recording.

When set to “STOP”, the Stop mode is engaged at tape end even if repeat recording or auto rewind is set.

When set to “OFF”, VCR operation is determined by the repeat recording or auto rewind setting.

3Set the other menu switches.

5 Setting the alarm buzzer

Set the menu switch <AL/SENSOR IN> in <BUZZER> to “ON” to sound the alarm buzzer during alarm recording.

5 Setting the on-screen brightness and display items

Select the monitor display setting with the menu switch.

On-screen information is recorded together with the video signals.

You can change the on-screen display position with the [ON SCREEN 7/f] buttons on the front panel.

5 Setting the HDR

To record in the HIGH DENSITY REC mode during timelapse recording, set the menu switch <HIGH DENSITY REC> in <VTR MODE> to “ON”.

ALARM/SENSOR MODE screen

* * * * * [ SR I / EX T * MODE ] * * * * *

1 . SR I / EX T * * * * * * * * * * * * OF F

2. EX T * REC * END * * * * * NORMAL

3. CNT * TAPESEND * * * * * * * OF F * * [ ALARM / SENSOR * MODE ] * * *

1. REC * MODE * * * * * * * * * ALARMSet to “ALARM” or “AL/

2 . REC * T - MODE * * * * * * * * * OF F SENSOR”. 3 . DURAT I ON * * * * * * * * 1 8 0 SEC

4. TAPE * END * MODE * * * * * * OF F

5. AUTO * REW* * * * * * * * * * * OF F

6. REPEAT * P LAY * * * * * * * * OF F

7. REPEAE * REC * * * * * * * * * OF F

4Select the timelapse recording mode with the [TIME MODE +/–] button on the front panel.

[The selected recording speed mode is shown on the VCR’s display and on the monitor.

5Follow the procedure described in “Recording Basic Operation” on page 30.

6When an alarm signal is input to the rear panel’s [ALARM IN] terminal, alarm recording is executed in accordance with the specified settings.

7To stop alarm recording and clear the [ALARM] indication, press the [RESET/CANCEL] button.

If the [RESET/CANCEL] button is pressed when the “AL” indication is lit (during alarm recording), alarm recording stops, the “AL” indication goes out, and timelapse recording is restored. If the alarm buzzer is on, the buzzer sound also stops.

If the “AL” indication blinks and the [RESET/CANCEL] button is pressed, the “AL” indication goes out.

In this case, even if the menu switch <TAPE END MODE> is set to “STOP”, the operation executed at end of the tape is determined by the setting of the <AUTO REW> or <REPEAT REC> menu switch in the <VTR MODE> menu.

8The alarm input data can be checked in the main menu’s <ALARM RECALL/POWER LOSS> menu (refer to page 21).

Display the alarm list screen and press the [RESET/ CANCEL] button to reset the alarm input data.

*There may be some picture distortion at the start or end of an alarm recording. This is not a malfunction.

39

Image 39
Contents VQT9726 OperatingInformation Safety PrecautionsLock indicator Lock button Operation LockTime MODE+/- button Page Contents Introduction Major FeaturesPeriodical Maintenance PrecautionsIntroduction Erasure prevention tab Inspection procedureDaily Inspection Regarding S-VHS ET RecordingFront Panel Controls and ConnectorsControls and Connectors Display Rear Panel COM common ground terminal Series REC OUT series recording signal output terminalConnections Connecting to a CameraConnections System Using Sequential SwitcherConnecting the Rear Panel Input/Output Terminal Connections Changing the on-screen display brightness ON-SCREEN/MENU SwitchesDisplay items On Screen Mode screen On-Screen DisplayON-SCREEN/MENU Switches Contents of the main menu itemsMain Menu Display Date and Time Setting Time setting item and the hour digit blinksSet to OFF Standard time Time setting for 29 seconds or lessHour Meter Display During Daylight Savings timeAlarm Input/Power Loss Data Display Resetting alarm input/power loss failure dataWith the second item Menu Switch Setting Contents of Menu Switches Screens Items Set values Set values Function ScreensContinue Mode StopREC T-MODE Duration SECAuto play PreparationCassette Loading/Unloading Auto operate on120 Recording/Playback Speed Mode SelectionPreparation High-Density RecordingConnection Switch Setting During RecordingMenu switch settings RecordingRecording Basic Operation RecordingTimer Recording Timer Recording Program SettingPreparation Press the Shift 7 button so that the next setting RPT Timer recording is executed on the specified dayOFF Programmed timer recording is not executed To program timer recording at another time or dayProgramming timer recording for more than 24 hours Timer button Menu buttonShift 7 button Shift f button Program Timer screen Recording speed On Enabled OFF DisabledStop time Start time Day of the week MonthDay Holiday Timer Recording SettingT + Timer button Menu button SET button SET + button Holiday SET screenTo cancel preset timer programs Canceling/Changing Timer Recording ProgramTo modify timer programs To stop timer programming before finishingIf no cassette is loaded During timer recordingTimer recording If programmed data overlapAlarm Recording Timelapse Alarm Recording Alarm signal input48H/NORMAL Setting the HDR Tape END ModeSetting the alarm buzzer Setting the on-screen brightness and display itemsSensor recording will be performed When set to AL/SENSOR, both alarm recordingAlarm signals are input Sensor RecordingRepeat for all connected VCRs Series RecordingConnections OperationSecond VCR First VCR Connection SettingNon-stop continuous series recording Counter valueOperation of the automatic recording check function ALARM/SENSOR ModeWhen the Auto REC Check menu switch is set to on Repeat RecordingSRI/EXT Mode screen Recording with External VCR Activation SignalAlarm search/date and time search VCR control signal ground signalTape End Buzzer How to Restore Recording After Power FailureExternal Timer Recording VTR Mode screenTo stop playback Menu switch settingPreparation PlaybackField advance playback Playback and SPECIAL-EFFECTS PlaybackSpecial-Effects Playback Still playbackPlay button Shuttle search reverse and fast-forward playbackFast-forward shuttle search Reverse shuttle search REW buttonAlarm number Alarm Search/Date and Time SearchAlarm search Alarm search setting screenDate/time search Alarm scanIs located, the Stop mode is engaged Date/Time Search mode is canceledAuto rewind CNT Reset button Display buttonRepeat Playback Counter Memory FunctionLock +/- buttons Tracking +/- buttons Tracking/V. Lock AdjustmentTroubleshooting Error IndicationsError Contents VCR operation Measures No Error Indication TroubleshootingTape Reel Counter/Tape Remaining Time Table AppendixesRear Panel’s Inputs/Outputs Terminals Signal levels Remarks 2H/6H recordingRecording signal input AppendixesVideo System SpecificationsAlarm Time/dateIndustrial Medical Group Security Systems GroupEastern Zone Office Western Zone Office

AG-TL950 specifications

The Panasonic AG-TL950 is a professional-grade broadcast monitor designed to meet the rigorous standards of the film and television industry. This monitor is particularly geared towards production environments that require precision, reliability, and high-quality imaging. With its rich feature set and advanced technologies, the AG-TL950 is a powerful tool for any broadcast or film professional.

One of the standout features of the AG-TL950 is its high-resolution display. The monitor supports 4K resolution, providing crystal-clear image quality and allowing users to see fine details that are critical during production and editing processes. This high resolution, combined with excellent color accuracy, ensures that content creators can trust the colors they are seeing on-screen, which is essential for color grading and post-production work.

The AG-TL950 also employs advanced HDR (High Dynamic Range) technology, which enhances the monitor’s contrast and color range, allowing for a more realistic and immersive viewing experience. This makes it particularly valuable for filmmakers and production teams working on projects that require adherence to modern HDR standards.

Connectivity is another strong suit of the AG-TL950. The monitor is equipped with a variety of input options, including 12G-SDI, HDMI, and both analog and digital audio inputs. This flexibility allows it to integrate smoothly into existing production workflows and ensures compatibility with a wide range of video sources.

In addition to its impressive visual capabilities, the AG-TL950 includes essential features for professional monitoring. It offers waveform and vector scope displays, allowing users to analyze and adjust their signals accurately. Furthermore, the monitor has customizable monitoring options, enabling users to set up to 16 user-defined presets for quick access to their most-used settings.

The design of the AG-TL950 reflects its professional focus, with a robust build quality that speaks to its reliability in dynamic production environments. Its lightweight design makes it easy to transport, while the wide viewing angles ensure that multiple crew members can view the monitor clearly from different positions.

In conclusion, the Panasonic AG-TL950 monitor integrates advanced display technology, versatile connectivity, and user-friendly monitoring features. It stands out as an essential tool for professional filmmakers and broadcast engineers, enabling them to create high-quality visuals with accuracy and confidence.