Panasonic AG-TL950 appendix Alarm Search/Date and Time Search, Alarm search setting screen

Page 49

7 PLAYBACK AND SPECIAL-EFFECTS PLAYBACK

REC

POWER

STOP

 

 

 

 

 

 

 

POWER

 

 

 

 

HDR

PAUSE/

 

 

 

 

/REW REV PLAY STILL

PLAY FF/

TRACKING

V. LOCK

TIMER SEARCH COUNTER LOCK CNT RESET

 

 

REV ADV

FWD ADV

 

 

 

EJECT

REC REVIEW REC

RESET/

 

 

CANCEL

ON SCREEN

 

 

SHIFT

 

MENU

TIME MODE

 

 

SET

AG-

 

 

[REW] button [FF] button [SEARCH] button

[SET +/–] button

[SHIFT f] button

7-4 Alarm Search/Date and Time Search

There are three different ways you can search a tape position.

When the [SEARCH] button is pressed, the Search mode is engaged. Each time the [SEARCH] button is pressed, the Search mode changes.

(Once) alarm search: To search the start of an alarm recording.

(Twice) alarm scan: To play back around the start of each alarm recording for several seconds.

(Three times) date/time search: To search for a recording made at a specified date and time. Press the [SEARCH] button four times to cancel the Search mode.

Note on date/time search

Recording duration is especially important with timelapse recordings. If the duration is too short, date/time search will not function correctly. The recording duration must be equivalent to at least 5 seconds at Standard (2H) or EP (6H) speed.

(Example) In the 960-hour normal timelapse mode, the recording time should be 40 minutes or more.

Alarm search setting screen

ALARM : SRH * 0 1 * * * * * * * * * * * *

0 0 H 0 0M0 1 S * * FR I * * * * * * * * * *

AL – 0 5 6 * BL P L – 0 4 * AUTO * * * * *

* ZOControlOMONUMor. *reel* * * counter* M. * * * * * * *

* MACR * * T E L E * * * * A . * * * * * * *

* DAT EEHEURE * * * * * * * * * * * * *

* DURE * * BANDE * * * T 4 5 * * * * * *

* * * * * * * * * * * * * * * * * * * * * * * *

* * * * * * * * * * * * * * * * * * * * * * * *

* * * * * * * * * * * * * * * * * * * * * * * *

* * * * * * * * * * * * * * * * * * * * * * * *

* 4F I N DE * MENU * * * * * * * * * * *

VCR’s display

Alarm number (01- 99)

To specify the alarm recording to be cued, enter the alarm number with respect to the current tape position in the forward or reverse direction.

Alarm search

A specified alarm recording is searched and the Stop mode is engaged.

1Press the [SEARCH] button once in the Stop mode. [The VCR enters the Alarm Search mode and the

alarm search setting screen is shown on the monitor. The “AL01” indication blinks in the record/playback speed mode indication section on the display.

*To cancel the Alarm Search mode, press the [SEARCH] button three times.

2Specify the alarm recording you want to search.

Press the [SET +] or [SET –] button to specify an alarm number from 01 to 99.

The specified alarm number is shown on the monitor and the VCR’s display. The alarm number is not absolute; it depends on the current tape position.

Alarm number

3Press the [FF] or [REW] button.

[The VCR fast forwards or rewinds.

When the start of the alarm recording with the specified alarm number is located, search stops and the Stop mode is engaged.

The Alarm Search mode is automatically canceled.

49

Image 49
Contents VQT9726 OperatingInformation Safety PrecautionsOperation Lock Lock indicator Lock buttonTime MODE+/- button Page Contents Introduction Major FeaturesPrecautions Periodical MaintenanceIntroduction Daily Inspection Inspection procedureRegarding S-VHS ET Recording Erasure prevention tabFront Panel Controls and ConnectorsControls and Connectors Display Rear Panel COM common ground terminal Series REC OUT series recording signal output terminalConnections Connecting to a CameraConnections System Using Sequential SwitcherConnecting the Rear Panel Input/Output Terminal Connections Display items On Screen Mode screen ON-SCREEN/MENU SwitchesOn-Screen Display Changing the on-screen display brightnessContents of the main menu items ON-SCREEN/MENU SwitchesMain Menu Display Time setting item and the hour digit blinks Date and Time SettingSet to OFF Hour Meter Display Time setting for 29 seconds or lessDuring Daylight Savings time Standard timeResetting alarm input/power loss failure data Alarm Input/Power Loss Data DisplayWith the second item Menu Switch Setting Contents of Menu Switches Screens Items Set values Set values Function ScreensREC T-MODE Mode StopDuration SEC ContinueCassette Loading/Unloading PreparationAuto operate on Auto playPreparation Recording/Playback Speed Mode SelectionHigh-Density Recording 120Menu switch settings Switch Setting During RecordingRecording ConnectionRecording Basic Operation RecordingTimer Recording Program Setting Timer RecordingPreparation OFF Programmed timer recording is not executed RPT Timer recording is executed on the specified dayTo program timer recording at another time or day Press the Shift 7 button so that the next settingTimer button Menu button Programming timer recording for more than 24 hoursShift 7 button Shift f button On Enabled OFF Disabled Program Timer screen Recording speedStop time Start time Day of the week T + Timer button Menu button SET button SET + button Holiday Timer Recording SettingHoliday SET screen MonthDayTo modify timer programs Canceling/Changing Timer Recording ProgramTo stop timer programming before finishing To cancel preset timer programsTimer recording During timer recordingIf programmed data overlap If no cassette is loadedTimelapse Alarm Recording Alarm signal input Alarm Recording48H/NORMAL Setting the alarm buzzer Tape END ModeSetting the on-screen brightness and display items Setting the HDRAlarm signals are input When set to AL/SENSOR, both alarm recordingSensor Recording Sensor recording will be performedConnections Series RecordingOperation Repeat for all connected VCRsNon-stop continuous series recording Connection SettingCounter value Second VCR First VCRWhen the Auto REC Check menu switch is set to on ALARM/SENSOR ModeRepeat Recording Operation of the automatic recording check functionAlarm search/date and time search Recording with External VCR Activation SignalVCR control signal ground signal SRI/EXT Mode screenExternal Timer Recording How to Restore Recording After Power FailureVTR Mode screen Tape End BuzzerPreparation Menu switch settingPlayback To stop playbackSpecial-Effects Playback Playback and SPECIAL-EFFECTS PlaybackStill playback Field advance playbackFast-forward shuttle search Reverse shuttle search Shuttle search reverse and fast-forward playbackREW button Play buttonAlarm search Alarm Search/Date and Time SearchAlarm search setting screen Alarm numberIs located, the Stop mode is engaged Alarm scanDate/Time Search mode is canceled Date/time searchRepeat Playback CNT Reset button Display buttonCounter Memory Function Auto rewindLock +/- buttons Tracking +/- buttons Tracking/V. Lock AdjustmentError Indications TroubleshootingError Contents VCR operation Measures No Error Indication TroubleshootingTape Reel Counter/Tape Remaining Time Table AppendixesRecording signal input Terminals Signal levels Remarks 2H/6H recordingAppendixes Rear Panel’s Inputs/OutputsAlarm SpecificationsTime/date Video SystemEastern Zone Office Security Systems GroupWestern Zone Office Industrial Medical Group

AG-TL950 specifications

The Panasonic AG-TL950 is a professional-grade broadcast monitor designed to meet the rigorous standards of the film and television industry. This monitor is particularly geared towards production environments that require precision, reliability, and high-quality imaging. With its rich feature set and advanced technologies, the AG-TL950 is a powerful tool for any broadcast or film professional.

One of the standout features of the AG-TL950 is its high-resolution display. The monitor supports 4K resolution, providing crystal-clear image quality and allowing users to see fine details that are critical during production and editing processes. This high resolution, combined with excellent color accuracy, ensures that content creators can trust the colors they are seeing on-screen, which is essential for color grading and post-production work.

The AG-TL950 also employs advanced HDR (High Dynamic Range) technology, which enhances the monitor’s contrast and color range, allowing for a more realistic and immersive viewing experience. This makes it particularly valuable for filmmakers and production teams working on projects that require adherence to modern HDR standards.

Connectivity is another strong suit of the AG-TL950. The monitor is equipped with a variety of input options, including 12G-SDI, HDMI, and both analog and digital audio inputs. This flexibility allows it to integrate smoothly into existing production workflows and ensures compatibility with a wide range of video sources.

In addition to its impressive visual capabilities, the AG-TL950 includes essential features for professional monitoring. It offers waveform and vector scope displays, allowing users to analyze and adjust their signals accurately. Furthermore, the monitor has customizable monitoring options, enabling users to set up to 16 user-defined presets for quick access to their most-used settings.

The design of the AG-TL950 reflects its professional focus, with a robust build quality that speaks to its reliability in dynamic production environments. Its lightweight design makes it easy to transport, while the wide viewing angles ensure that multiple crew members can view the monitor clearly from different positions.

In conclusion, the Panasonic AG-TL950 monitor integrates advanced display technology, versatile connectivity, and user-friendly monitoring features. It stands out as an essential tool for professional filmmakers and broadcast engineers, enabling them to create high-quality visuals with accuracy and confidence.