Panasonic AG-TL950 appendix Preparation, Playback, To stop playback, Menu switch setting

Page 46

7 PLAYBACK AND SPECIAL-EFFECTS PLAYBACK

[STOP] button

[POWER] indicator

 

REC

POWER

STOP

 

 

 

 

 

 

 

POWER

 

 

 

 

HDR

PAUSE/

 

 

 

 

/REW REV PLAY STILL

PLAY FF/

TRACKING

V. LOCK

TIMER SEARCH COUNTER LOCK CNT RESET

 

 

REV ADV

FWD ADV

 

 

 

EJECT

REC REVIEW REC

RESET/

 

 

CANCEL

ON SCREEN

 

 

SHIFT

 

MENU

TIME MODE

 

 

SET

AG-

 

 

[POWER] button [PLAY] button Playback mode indicator [TIME MODE+/–] button

7-1 Preparation

Connection

Connect the output connectors on the rear panel correctly.

Menu switch setting

Set the menu switches in <VIDEO/VTR MODE> as required.

5[DETAIL] ... Factory setting: OFF

Set to “ON” to improve reproduction of picture detail. However, the S/N ratio will be degraded.

5[QUASI-V] ... Factory setting: OFF

Set to “ON” to add V. pulse in the normal play (2H or 6H) mode.

5[MEMORY STOP] ... Factory setting: ON Counter memory ON/OFF.

Set to “ON” to use the counter memory function.

5[AUTO REW] ... Factory setting: OFF Automatic rewind ON/OFF.

Set to “ON” to rewind the tape to the beginning when the tape ends.

5[REPEAT PLAY] ... Factory setting: OFF Repeat playback ON/OFF.

Set to “ON” to execute repeat playback.

*Noise may appear in the picture with tapes not recorded on the AG-TL950P.

Notes on playback

Tapes recorded on this VCR cannot be played back on standard VHS VCRs. Use this VCR, an S-VHS VCR or a VCR with SQPB function to play back tapes recorded on this unit. Also be aware that not all S-VHS VCRs will be able to play back tapes recorded on this unit, because some use different S-VHS/VHS detection methods.

Try to avoid operations such as shuttle search or field advance playback as much as possible. These put a comparatively high stress load on the tape and can lead to picture degradation over time.

During shuttle search or field advance playback, noise may appear. This is normal with this unit and is not a malfunction.

7-2 Playback

1Press the [POWER] button to turn the operating mode on.

The [POWER] indicator lights.

2Press the [TIME MODE +/–] button to set the play mode to 2H (SP) or 6H (EP) mode.

The [2H] or [6H] indication is shown on the display.

To play back a tape recorded in the timelapse mode at slow speed, press the [TIME MODE +/–] button to set the desired mode (24H, 48H..... 960H) (slow play).

Avoid using slow-motion playback continuously for long periods (more than several hours).

3Load the recorded cassette correctly.

*If a cassette is loaded when the operating mode is off, the operating mode is switched on automatically (auto operate on function).

If the cassette’s safety tab has been removed, the operating mode is turned on and play starts automatically (auto play function).

4Press the [PLAY] button to start play.

The play indicator is shown on the display and the Play mode is engaged.

When a tape recorded in the HDR mode is played back, the [HDR] indicator lights.

* No sound is output in the Timelapse Play mode.

When the play mode is set to 2H (SP) or 6H (EP), playback operates as follows.

Cassettes recorded in the 2H or ordinary (SP) Timelapse modes are played back in the 2H (SP) mode. [2H] is shown on the display.

Cassettes recorded in the 6H or HDR Timelapse mode are played back in the 6H (EP) mode. [6H] is shown on the display

To stop playback

5Press the [STOP] button.

The tape stops and the Stop mode is engaged.

46

Image 46
Contents Operating VQT9726Safety Precautions InformationOperation Lock Lock indicator Lock buttonTime MODE+/- button Page Contents Major Features IntroductionPrecautions Periodical MaintenanceIntroduction Regarding S-VHS ET Recording Inspection procedureDaily Inspection Erasure prevention tabControls and Connectors Front PanelControls and Connectors Display Rear Panel Series REC OUT series recording signal output terminal COM common ground terminalConnecting to a Camera ConnectionsSystem Using Sequential Switcher ConnectionsConnecting the Rear Panel Input/Output Terminal Connections On-Screen Display ON-SCREEN/MENU SwitchesDisplay items On Screen Mode screen Changing the on-screen display brightnessContents of the main menu items ON-SCREEN/MENU SwitchesMain Menu Display Time setting item and the hour digit blinks Date and Time SettingSet to OFF During Daylight Savings time Time setting for 29 seconds or lessHour Meter Display Standard timeResetting alarm input/power loss failure data Alarm Input/Power Loss Data DisplayWith the second item Menu Switch Setting Contents of Menu Switches Screens Items Set values Screens Set values FunctionDuration SEC Mode StopREC T-MODE ContinueAuto operate on PreparationCassette Loading/Unloading Auto playHigh-Density Recording Recording/Playback Speed Mode SelectionPreparation 120Recording Switch Setting During RecordingMenu switch settings ConnectionRecording Recording Basic OperationTimer Recording Program Setting Timer RecordingPreparation To program timer recording at another time or day RPT Timer recording is executed on the specified dayOFF Programmed timer recording is not executed Press the Shift 7 button so that the next settingTimer button Menu button Programming timer recording for more than 24 hoursShift 7 button Shift f button On Enabled OFF Disabled Program Timer screen Recording speedStop time Start time Day of the week Holiday SET screen Holiday Timer Recording SettingT + Timer button Menu button SET button SET + button MonthDayTo stop timer programming before finishing Canceling/Changing Timer Recording ProgramTo modify timer programs To cancel preset timer programsIf programmed data overlap During timer recordingTimer recording If no cassette is loadedTimelapse Alarm Recording Alarm signal input Alarm Recording48H/NORMAL Setting the on-screen brightness and display items Tape END ModeSetting the alarm buzzer Setting the HDRSensor Recording When set to AL/SENSOR, both alarm recordingAlarm signals are input Sensor recording will be performedOperation Series RecordingConnections Repeat for all connected VCRsCounter value Connection SettingNon-stop continuous series recording Second VCR First VCRRepeat Recording ALARM/SENSOR ModeWhen the Auto REC Check menu switch is set to on Operation of the automatic recording check functionVCR control signal ground signal Recording with External VCR Activation SignalAlarm search/date and time search SRI/EXT Mode screenVTR Mode screen How to Restore Recording After Power FailureExternal Timer Recording Tape End BuzzerPlayback Menu switch settingPreparation To stop playbackStill playback Playback and SPECIAL-EFFECTS PlaybackSpecial-Effects Playback Field advance playbackREW button Shuttle search reverse and fast-forward playbackFast-forward shuttle search Reverse shuttle search Play buttonAlarm search setting screen Alarm Search/Date and Time SearchAlarm search Alarm numberDate/Time Search mode is canceled Alarm scanIs located, the Stop mode is engaged Date/time searchCounter Memory Function CNT Reset button Display buttonRepeat Playback Auto rewindTracking/V. Lock Adjustment Lock +/- buttons Tracking +/- buttonsError Indications TroubleshootingError Contents VCR operation Measures Troubleshooting No Error IndicationAppendixes Tape Reel Counter/Tape Remaining Time TableAppendixes Terminals Signal levels Remarks 2H/6H recordingRecording signal input Rear Panel’s Inputs/OutputsTime/date SpecificationsAlarm Video SystemWestern Zone Office Security Systems GroupEastern Zone Office Industrial Medical Group

AG-TL950 specifications

The Panasonic AG-TL950 is a professional-grade broadcast monitor designed to meet the rigorous standards of the film and television industry. This monitor is particularly geared towards production environments that require precision, reliability, and high-quality imaging. With its rich feature set and advanced technologies, the AG-TL950 is a powerful tool for any broadcast or film professional.

One of the standout features of the AG-TL950 is its high-resolution display. The monitor supports 4K resolution, providing crystal-clear image quality and allowing users to see fine details that are critical during production and editing processes. This high resolution, combined with excellent color accuracy, ensures that content creators can trust the colors they are seeing on-screen, which is essential for color grading and post-production work.

The AG-TL950 also employs advanced HDR (High Dynamic Range) technology, which enhances the monitor’s contrast and color range, allowing for a more realistic and immersive viewing experience. This makes it particularly valuable for filmmakers and production teams working on projects that require adherence to modern HDR standards.

Connectivity is another strong suit of the AG-TL950. The monitor is equipped with a variety of input options, including 12G-SDI, HDMI, and both analog and digital audio inputs. This flexibility allows it to integrate smoothly into existing production workflows and ensures compatibility with a wide range of video sources.

In addition to its impressive visual capabilities, the AG-TL950 includes essential features for professional monitoring. It offers waveform and vector scope displays, allowing users to analyze and adjust their signals accurately. Furthermore, the monitor has customizable monitoring options, enabling users to set up to 16 user-defined presets for quick access to their most-used settings.

The design of the AG-TL950 reflects its professional focus, with a robust build quality that speaks to its reliability in dynamic production environments. Its lightweight design makes it easy to transport, while the wide viewing angles ensure that multiple crew members can view the monitor clearly from different positions.

In conclusion, the Panasonic AG-TL950 monitor integrates advanced display technology, versatile connectivity, and user-friendly monitoring features. It stands out as an essential tool for professional filmmakers and broadcast engineers, enabling them to create high-quality visuals with accuracy and confidence.