VIP XD | Configuration Using a Web Browser en 27 |
|
|
Daylight saving time
The internal clock can switch automatically between normal and daylight saving time (DST). The unit already contains the data for DST
NOTICE!
i | If you do not create a table, there will be no automatic switching. When changing and clearing |
| |
| individual entries, remember that two entries are usually related to each other and dependent |
| on one another (switching to summer time and back to normal time). |
|
|
1.First check whether the correct time zone is selected. If it is not correct, select the appropriate time zone for the system, and click the Set button.
2.Click the Details button. A new window will open and you will see the empty table.
3.Select the region or the city that is closest to the system's location from the list field below the table.
4.Click the Generate button to generate data and enter this into the table.
5.Make changes by clicking an entry in the table. The entry is selected.
6.Clicking the Delete button will remove the entry from the table.
7.Select other values from the list fields below the table to change the entry. Changes are made immediately.
8.If there are empty lines at the bottom of the table, for example after deletions, you can add new data by marking the row and selecting required values from the list fields.
9.Now click the OK button to save and activate the table.
Time server IP address
Enter the IP address of a time server.
Time server type
The VIP XD can receive the time signal from a time server using various time server protocols, and then use it to set the internal clock. The unit polls the time signal automatically once every minute.
Select the protocol that is supported by the selected time server. Preferably, you should select the SNTP server as the protocol. This supports a high level of accuracy and is required for special applications and subsequent function extensions.
Select Time server for a time server that works with the protocol RFC 868.
Bosch Security Systems | Installation and Operating Manual | DOC V4.0 2009.06 |