Bosch Appliances XD Details, Horizontal synchronization / Vertical synchronization, Border color

Page 32

32 en Configuration Using a Web Browser

VIP XD

 

 

Details

The Details window allows you to adapt the video output signal to specific requirements with greater detail. You can also set the frame color for the image border.

Horizontal synchronization / Vertical synchronization

Here you can select the way in which the relevant synchronization pulse will be output.

Border color

You can set the required gray tone for the outer frame and any separating lines between the video images for a quad view screen, if necessary.

Click the arrows or move the slide control while holding down the mouse button.

Sync. length / Retrace length / Sync. position

Here you can match the settings for the synchronization signals to specific requirements, if necessary.

Resetting Changes

You can undo all the changes you have made to the profiles and restore each profile to its original settings.

1.Click the Defaults button to reset the settings for the profile currently displayed to their default values.

2.If you wish to discard changes to a profile that you have not yet explicitly saved, click the Discard button. You will see the last saved settings for that profile.

Saving Changes

Once you have tested your settings on the connected monitor by clicking the Test button, you can save the new settings. Settings will only be saved for the currently displayed profile. Click the Save button to save the current profile with the settings displayed.

DOC V4.0 2009.06

Installation and Operating Manual

Bosch Security Systems

Image 32
Contents VIP XD Page Table of Contents Maintenance and Upgrades SpecificationsOperation AppendixPreface About this ManualConventions in this Manual Intended UseEU Directives Rating PlateSafety Information Installation and OperationMaintenance and Repair Electric Shock HazardEn Safety Information Product Description Scope of DeliveryAdditional Configuration Requirements System RequirementsGeneral Requirements Additional Operational RequirementsOverview of Functions Summary HttpsConnections on the Front Panel Connections on the Rear Panel LED4Installation 1Preparations2Connections Data Interface Alarm InputsNetwork Relay Output Maximum rating of the relay contact is 30 V and 2 a SelvPower On/Power Off Setup Using the Configuration ManagerPower Supply Installing the ProgramConfiguring the VIP XD Click Unit network settings... in the popup menuReboot Additional ParametersConfiguration Using a Web Browser 1ConnectingInstalling Mpeg ActiveX System RequirementsEstablishing the Connection Maximum Number of ConnectionsProtected VIP XD Protected NetworkMaking Changes Configuration MenuNavigation 4Password 3IdentificationDevice ID Device name5Date/Time Time server type Daylight saving timeTime server IP address 6Appearance Website languageCompany logo Device logoDecoder Profile Monitor nameStandard Overscan8VGA VGA screen sizeResolution Refresh rateBorder top / bottom / left / right Horiz. spacing / Vert. spacingResetting Changes DetailsHorizontal synchronization / Vertical synchronization Border colorMonitor Display Audio Audio Version OnlyAlarm Connections Connect on alarmLine In / Microphone MIC Line Out/Speaker SPKDestination password Number of destination IP addressDestination IP address Video transmissionAudio Audio Version Only Default cameraAuto-connect Audio Alarm Audio Version Only Audio alarmName ThresholdAlarm E-Mail Format Standard E-mailDestination address Sender nameAlarm Task Editor Alarm Inputs Alarm inputRelay Idle stateOperating mode 10 s Relay followsOff Connection17 COM1 Network Automatic IP assignment IP addressSubnet mask Gateway addressInterface mode ETH Enable DynDNSRCP+ port Telnet supportSnmp host address / 2. Snmp host address AdvancedStatus Authentication EncryptionSnmp traps IdentityMaintenance Firmware192.168.0.32/reset Maintenance logUpload DownloadLicenses System OverviewFunction Test 6Operation En Operation Protected VIP XD Monitor 2The ConnectionsPreview Connections Between the Sender and Receiver Multicast scan Controlling ConnectionsSelecting Decoder for Quad View Connecting Connecting on AlarmConnecting with a Terminal Program Hardware Connections Between Video Servers5Operation with Management Software 2Unit Reset Maintenance and UpgradesTesting the Network Connection Repairs Transfer and Disposal8Appendix 1TroubleshootingMalfunction Possible causes Recommended solution En AppendixVIP XD LEDs 3Processor LoadNetwork Connection Operating Status LEDContact RS-232 mode RS-422 mode RS-485 mode Serial InterfaceTerminal Block Pin AssignmentConfiguring the Terminal Command InputsCommunication with Terminal Program Data TerminalAssigning an IP Address 8Copyrights En Appendix Audio Version Only SpecificationsUnit Protocols/Standards PAL, NtscGlossary GOP HttpIcmp IeeeMIB MPEG-2MPEG-4 MSSSnia SnmpSntp SSLRadius IndexEprom Serial number Serial port function Signal source SMS Page Bosc h Sicherheitssysteme GmbH