5.7

Decoder Profile

In this screen you can set the various options for the display of video images on an analog monitor or VGA monitor. A number of presets are available for configuring the VGA video output signal. These presets can be adapted to individual requirements if necessary.

Monitor name

You can give the monitor connected to the VIP XD a name to make it easier to identify. The name makes the task of administering multiple units in larger video monitoring systems easier, for example using the VIDOS or Bosch Video Management System programs.

The monitor name allows you to remotely identify the monitor location. For this reason, enter a name that makes it as easy as possible to quickly identify the location.

Standard

CAUTION!

!Be sure to choose the correct video standard to avoid damaging the monitor. Selecting a VGA setting with values outside the technical specification of the monitor can result in severe

damage to the monitor. Refer to the technical documentation of the monitor you are using.

You can adapt the video output signal to the monitor you are using. Eight pre-configured settings for VGA monitors are available in addition to the PAL and NTSC options for analog video monitors.

Each pre-configured setting gives priority to different factors (resolution, border settings, refresh rate).

Details of the settings can be seen in the VGA field. Here you can also adapt the options to individual requirements if necessary.

1.Test different pre-configured settings from the list to obtain an optimum monitor image.

2.After selecting a setting, click the Set button to activate the setting at the video output.

Overscan

You can use the Overscan function to display images with clear, straight edges that go right up to the monitor margins.

Deactivate the Overscan function if you are using an analog monitor and single view display.

Window layout

You can specify the default image layout for the monitor. The image layout can also be selected at any time during operation on the CONNECTIONS page.

Bosch Security Systems

Installation and Operating Manual

DOC V4.0 2009.06

Image 29
Contents VIP XD Page Table of Contents Specifications Maintenance and UpgradesOperation AppendixAbout this Manual PrefaceConventions in this Manual Intended UseRating Plate EU DirectivesInstallation and Operation Safety InformationMaintenance and Repair Electric Shock HazardEn Safety Information Scope of Delivery Product DescriptionSystem Requirements Additional Configuration RequirementsGeneral Requirements Additional Operational RequirementsOverview of Functions Https SummaryConnections on the Front Panel LED Connections on the Rear Panel1Preparations 4Installation2Connections Data Interface Alarm InputsNetwork Maximum rating of the relay contact is 30 V and 2 a Selv Relay OutputSetup Using the Configuration Manager Power On/Power OffPower Supply Installing the ProgramClick Unit network settings... in the popup menu Configuring the VIP XDReboot Additional Parameters1Connecting Configuration Using a Web BrowserInstalling Mpeg ActiveX System RequirementsMaximum Number of Connections Establishing the ConnectionProtected Network Protected VIP XDMaking Changes Configuration MenuNavigation 3Identification 4PasswordDevice ID Device name5Date/Time Time server type Daylight saving timeTime server IP address Website language 6AppearanceCompany logo Device logoMonitor name Decoder ProfileStandard OverscanVGA screen size 8VGARefresh rate ResolutionBorder top / bottom / left / right Horiz. spacing / Vert. spacingDetails Resetting ChangesHorizontal synchronization / Vertical synchronization Border colorAudio Audio Version Only Monitor DisplayConnect on alarm Alarm ConnectionsLine In / Microphone MIC Line Out/Speaker SPKNumber of destination IP address Destination passwordDestination IP address Video transmissionAudio Audio Version Only Default cameraAuto-connect Audio alarm Audio Alarm Audio Version OnlyName ThresholdAlarm E-Mail Standard E-mail FormatDestination address Sender nameAlarm Task Editor Alarm input Alarm InputsRelay Idle state10 s Relay follows Operating modeOff Connection17 COM1 Network IP address Automatic IP assignmentSubnet mask Gateway addressEnable DynDNS Interface mode ETHRCP+ port Telnet supportSnmp host address / 2. Snmp host address AdvancedStatus Encryption AuthenticationSnmp traps IdentityFirmware MaintenanceMaintenance log 192.168.0.32/resetUpload DownloadSystem Overview LicensesFunction Test 6Operation En Operation Protected VIP XD Monitor 2The ConnectionsPreview Connections Between the Sender and Receiver Multicast scan Controlling ConnectionsSelecting Decoder for Quad View Connecting on Alarm ConnectingConnecting with a Terminal Program Hardware Connections Between Video Servers5Operation with Management Software 2Unit Reset Maintenance and UpgradesTesting the Network Connection Transfer and Disposal Repairs8Appendix 1TroubleshootingMalfunction Possible causes Recommended solution En AppendixVIP XD 3Processor Load LEDsNetwork Connection Operating Status LEDSerial Interface Contact RS-232 mode RS-422 mode RS-485 modeTerminal Block Pin AssignmentCommand Inputs Configuring the TerminalCommunication with Terminal Program Data TerminalAssigning an IP Address 8Copyrights En Appendix Audio Version Only SpecificationsUnit PAL, Ntsc Protocols/StandardsGlossary Http GOPIcmp IeeeMPEG-2 MIBMPEG-4 MSSSnmp SniaSntp SSLRadius IndexEprom Serial number Serial port function Signal source SMS Page Bosc h Sicherheitssysteme GmbH