Bosch Appliances VIP, XD Maintenance and Upgrades, Testing the Network Connection, 2Unit Reset

Page 61

VIP XDMaintenance and Upgrades en 61

7

Maintenance and Upgrades

7.1

Testing the Network Connection

You can use the ping command to check the connection between two IP addresses. This allows you to test whether a unit in the network is active.

1.Open the DOS command prompt.

2.Type ping followed by the IP address of the unit.

If the unit is found, the response appears as Reply from ... followed by the number of bytes sent and the transmission time in milliseconds. If not, the unit cannot be accessed over the network. This might be because:

The unit is not correctly connected to the network. Check the cable connections in this case.

The unit is not correctly integrated into the network. Check the IP address, subnet mask and gateway address.

7.2Unit Reset

You can use the Factory Reset button to restore the unit to its original settings. Any changes to the settings are overwritten by the factory defaults. A reset may be necessary, for example, if the unit has invalid settings that prevent it from functioning as desired.

CAUTION!

!All configured settings will be discarded during a reset.

If necessary, back up the current configuration using the Download button on the Maintenance configuration page (see Section 5.21 Maintenance, page 49).

NOTICE!

i

After a reset, the unit can only be addressed via the factory default IP address. The IP address

 

 

can be changed as described in the Installation chapter (see Section 4.4 Setup Using the

 

Configuration Manager, page 19).

 

 

1.If necessary, back up the current configuration using the Download button on the Maintenance configuration page (see Section 5.21 Maintenance, page 49).

2.Using a pointed object, press the factory reset button until the operating status LED flashes red (see Section 3.5 Connections on the Rear Panel, page 14). All settings will revert to their defaults.

3.Change the IP address of the VIP XD if necessary.

4.Configure the unit to meet your requirements.

Bosch Security Systems

Installation and Operating Manual

DOC V4.0 2009.06

Image 61
Contents VIP XD Page Table of Contents Specifications Maintenance and UpgradesOperation AppendixAbout this Manual PrefaceConventions in this Manual Intended UseRating Plate EU DirectivesInstallation and Operation Safety InformationMaintenance and Repair Electric Shock HazardEn Safety Information Scope of Delivery Product DescriptionSystem Requirements Additional Configuration RequirementsGeneral Requirements Additional Operational RequirementsOverview of Functions Https SummaryConnections on the Front Panel LED Connections on the Rear Panel1Preparations 4Installation2Connections Network Alarm InputsData Interface Maximum rating of the relay contact is 30 V and 2 a Selv Relay OutputSetup Using the Configuration Manager Power On/Power OffPower Supply Installing the ProgramClick Unit network settings... in the popup menu Configuring the VIP XDReboot Additional Parameters1Connecting Configuration Using a Web BrowserInstalling Mpeg ActiveX System RequirementsMaximum Number of Connections Establishing the ConnectionProtected Network Protected VIP XDNavigation Configuration MenuMaking Changes 3Identification 4PasswordDevice ID Device name5Date/Time Time server IP address Daylight saving timeTime server type Website language 6AppearanceCompany logo Device logoMonitor name Decoder ProfileStandard OverscanVGA screen size 8VGARefresh rate ResolutionBorder top / bottom / left / right Horiz. spacing / Vert. spacingDetails Resetting ChangesHorizontal synchronization / Vertical synchronization Border colorAudio Audio Version Only Monitor DisplayConnect on alarm Alarm ConnectionsLine In / Microphone MIC Line Out/Speaker SPKNumber of destination IP address Destination passwordDestination IP address Video transmissionAuto-connect Default cameraAudio Audio Version Only Audio alarm Audio Alarm Audio Version OnlyName ThresholdAlarm E-Mail Standard E-mail FormatDestination address Sender nameAlarm Task Editor Alarm input Alarm InputsRelay Idle state10 s Relay follows Operating modeOff Connection17 COM1 Network IP address Automatic IP assignmentSubnet mask Gateway addressEnable DynDNS Interface mode ETHRCP+ port Telnet supportStatus AdvancedSnmp host address / 2. Snmp host address Encryption AuthenticationSnmp traps IdentityFirmware MaintenanceMaintenance log 192.168.0.32/resetUpload DownloadSystem Overview LicensesFunction Test 6Operation En Operation Protected VIP XD Preview 2The ConnectionsMonitor Connections Between the Sender and Receiver Selecting Decoder for Quad View Controlling ConnectionsMulticast scan Connecting on Alarm ConnectingConnecting with a Terminal Program Hardware Connections Between Video Servers5Operation with Management Software Testing the Network Connection Maintenance and Upgrades2Unit Reset Transfer and Disposal RepairsMalfunction Possible causes Recommended solution 1Troubleshooting8Appendix En AppendixVIP XD 3Processor Load LEDsNetwork Connection Operating Status LEDSerial Interface Contact RS-232 mode RS-422 mode RS-485 modeTerminal Block Pin AssignmentCommand Inputs Configuring the TerminalCommunication with Terminal Program Data TerminalAssigning an IP Address 8Copyrights En Appendix Unit SpecificationsAudio Version Only PAL, Ntsc Protocols/StandardsGlossary Http GOPIcmp IeeeMPEG-2 MIBMPEG-4 MSSSnmp SniaSntp SSLEprom IndexRadius Serial number Serial port function Signal source SMS Page Bosc h Sicherheitssysteme GmbH
Related manuals
Manual 7 pages 2.9 Kb