Bosch Appliances VIP Number of destination IP address, Destination IP address, Video transmission

Page 35

VIP XD

Configuration Using a Web Browser en 35

 

 

Number of destination IP address

Specify the numbers of the IP addresses to be contacted in the event of an alarm. The unit contacts the remote stations one after the other in the numbered sequence until a connection is made.

Destination IP address

For each number, enter the corresponding IP address for the desired remote station.

Destination password

If the remote station is password protected, enter the password here.

In this page, you can save a maximum of ten destination IP addresses and hence up to ten passwords for connecting to remote stations. If connections to more than ten remote stations are to be possible, for example when initiating connections via higher-ranking systems such as VIDOS or Bosch Video Management System, you can store a general password here. The VIP XD can use this general password to connect to all remote stations protected with the same password. In this case, proceed as follows:

1.Select 10 from the Number of destination IP address list field.

2.Enter the address 0.0.0.0 in the Destination IP address field.

3.Enter your chosen password in the Destination password field.

4.Define this password as the user password for all remote stations to which a connection is to be possible.

NOTICE!

i

If you enter the destination IP address 0.0.0.0 for destination 10, this VIP XD address will no

 

 

longer be used for the tenth attempt at automatic connection in the event of an alarm. The

 

parameter is then used only to save the general password.

 

 

Video transmission

If the unit is operated behind a firewall, TCP (HTTP port) should be selected as the transfer protocol. For use in a local network, select UDP.

CAUTION!

Please note that in some circumstances, a larger bandwidth must be available on the network

! for additional video images in the event of an alarm, in case Multicast operation is not possible. To enable Multicast operation, select the UDP option for the Video transmission parameter here and on the Network page (see Section Video transmission, page 45).

Remote port

Depending on the network configuration, select a browser port here. The ports for HTTPS connections will be available only if the On option is selected in the SSL encryption parameter.

Decoder

Select a decoder of the receiver to display the alarm image. The decoder selected has an impact on the position of the image in a split screen. For example, you can specify that the upper-right quadrant should be used to display the alarm image by selecting decoder 2.

SSL encryption

The data for the connection, for example the password, can be securely transmitted with SSL encryption. If you have selected the On option, only encrypted ports are offered in the Remote port parameter.

Bosch Security Systems

Installation and Operating Manual

DOC V4.0 2009.06

Image 35
Contents VIP XD Page Table of Contents Appendix Maintenance and UpgradesSpecifications OperationIntended Use PrefaceAbout this Manual Conventions in this ManualRating Plate EU DirectivesElectric Shock Hazard Safety InformationInstallation and Operation Maintenance and RepairEn Safety Information Scope of Delivery Product DescriptionAdditional Operational Requirements Additional Configuration RequirementsSystem Requirements General RequirementsOverview of Functions Https SummaryConnections on the Front Panel LED Connections on the Rear Panel1Preparations 4Installation2Connections Data Interface Alarm InputsNetwork Maximum rating of the relay contact is 30 V and 2 a Selv Relay OutputInstalling the Program Power On/Power OffSetup Using the Configuration Manager Power SupplyAdditional Parameters Configuring the VIP XDClick Unit network settings... in the popup menu RebootSystem Requirements Configuration Using a Web Browser1Connecting Installing Mpeg ActiveXMaximum Number of Connections Establishing the ConnectionProtected Network Protected VIP XDMaking Changes Configuration MenuNavigation Device name 4Password3Identification Device ID5Date/Time Time server type Daylight saving timeTime server IP address Device logo 6AppearanceWebsite language Company logoOverscan Decoder ProfileMonitor name StandardVGA screen size 8VGAHoriz. spacing / Vert. spacing ResolutionRefresh rate Border top / bottom / left / rightBorder color Resetting ChangesDetails Horizontal synchronization / Vertical synchronizationAudio Audio Version Only Monitor DisplayLine Out/Speaker SPK Alarm ConnectionsConnect on alarm Line In / Microphone MICVideo transmission Destination passwordNumber of destination IP address Destination IP addressAudio Audio Version Only Default cameraAuto-connect Threshold Audio Alarm Audio Version OnlyAudio alarm NameAlarm E-Mail Sender name FormatStandard E-mail Destination addressAlarm Task Editor Idle state Alarm InputsAlarm input RelayConnection Operating mode10 s Relay follows Off17 COM1 Network Gateway address Automatic IP assignmentIP address Subnet maskTelnet support Interface mode ETHEnable DynDNS RCP+ portSnmp host address / 2. Snmp host address AdvancedStatus Identity AuthenticationEncryption Snmp trapsFirmware MaintenanceDownload 192.168.0.32/resetMaintenance log UploadSystem Overview LicensesFunction Test 6Operation En Operation Protected VIP XD Monitor 2The ConnectionsPreview Connections Between the Sender and Receiver Multicast scan Controlling ConnectionsSelecting Decoder for Quad View Hardware Connections Between Video Servers ConnectingConnecting on Alarm Connecting with a Terminal Program5Operation with Management Software 2Unit Reset Maintenance and UpgradesTesting the Network Connection Transfer and Disposal Repairs8Appendix 1TroubleshootingMalfunction Possible causes Recommended solution En AppendixVIP XD Operating Status LED LEDs3Processor Load Network ConnectionPin Assignment Contact RS-232 mode RS-422 mode RS-485 modeSerial Interface Terminal BlockData Terminal Configuring the TerminalCommand Inputs Communication with Terminal ProgramAssigning an IP Address 8Copyrights En Appendix Audio Version Only SpecificationsUnit PAL, Ntsc Protocols/StandardsGlossary Ieee GOPHttp IcmpMSS MIBMPEG-2 MPEG-4SSL SniaSnmp SntpRadius IndexEprom Serial number Serial port function Signal source SMS Page Bosc h Sicherheitssysteme GmbH