Tour Setting

 

Value

 

 

 

 

 

 

 

Max. Random Dwell Time

 

20

 

 

 

 

 

 

 

 

Default Dwell Time

 

8

 

 

 

 

 

 

 

 

 

 

 

Tour Point

Preset Position

 

Dwell Time

 

 

 

 

 

 

1

1

 

 

 

Default

 

 

 

 

 

2

Random

 

 

5

 

 

 

 

 

3

Random

 

 

Random

 

 

 

 

 

 

 

First, the camera moves to preset position 1 and remains there for 8 seconds. It then moves

 

to a preset position between 5 and 15 and remains there for 5 seconds. Finally, it moves to

 

another preset (but not the one it has just visited) between 5 and 15, remaining there for a

 

random time between 10 and 20 seconds. This process then repeats, moving randomly only

 

the presets that it has not yet already visited. Once all the presets 5 to 15 have been visited,

 

the camera clears them.

 

Finally, Save Tour saves the modifications made to the tour number specified, whereas Exit

 

Without Saving discards the changes.

5.4

Pattern Tour Menu

 

The MIC 500 Series Camera supports two pattern tours which enable the user to record a

 

path or series of movements which can then be played back on repeat as a tour. The tour

number is selected from the “Main Menu” by pressing right on “Pattern Tour” and then up or down to select 1 or 2. Pressing right again enters the menu.

Recording a Pattern Tour

To record a pattern tour through the menu, specify the length in seconds required using the “Length” setting, and then press right on “Record.” The menu is removed and allows for full functional control, with a few overlaying captions indicating the tour number being recorded, the amount of time left, and the number of steps remaining. A single Pattern Tour can take up to 3000 readings, which are taken frequently during movement, and rarely when parked. Once the time has run out, the Menu is reloaded back to the same position. If the number of pattern steps runs out prior to the time, the recording is stopped and the menu reloaded.

Preview Tour

Once a tour has been recorded, it can be played back once through the menu using “Preview Tour.” As before, the menu is removed from the video and a caption added indicating the tour number being played. Once the tour has completed its run through, the menu reloads.

MAIN MENU

1/2

MIC SETUPS

ACTIVATE FEATURE

PRESET TOUR

PATTERN TOUR

PRESETS

COMMUNICATIONS

ADVANCED SETUPS

ALARMS

..PATTERN TOUR 1..

LENGTH

20 S

RECORD

REVIEW TOUR

F.01U.173.601 2.0 2010.11

User’s Manual

Bosch Security Systems, Inc.

Image 28
Contents MIC Series 500 Camera Page Table of Contents Appendices 1Safety Important Safety InstructionsSafety Precautions Important Notices Coax groundingFCC & Ices Information A. and Canadian Models OnlyInformations FCC ET Ices DisclaimerCopyright TrademarksCustomer Support and Service Parts List UnpackingAdditional Tools Required Quantity Part1Features 2Power3Description 3Video4Mounting Part DescriptionAdjusting the MIC 500 Series Camera Pan body fixing screwsCanting in progress Adjusting the Rain Shield for Inverted Operation Remove screwsMounting the MIC 500 Series Camera Lightning Protection Earthing the MIC 500 Series CameraElectrical Connections 13 Composite cable before connection Red Navigating the Menus Menu Item Description Exit1MIC Setups Menu Available only via the menu see .1.1 Config Mode,Setting Options Default ON/OFFTour ON/OFF OSDActivate Feature Menu 3Preset Tour MenuConfig Mode Image Flip Pan Reverse Tilt Reverse PrivacyCreate/Modify Tour Tour Setting ValueRandom Tours Tour Point Preset Position Dwell Time Pattern Tour MenuRecording a Pattern Tour Preview TourLearn Preset 5Presets MenuGoto Preset 6Communications Menu Manual ControlAdvanced Setups Menu Menu Item Description Options DefaultWipe Mode INTWipes Hour AutoFactory Defaults Re-map Pelco Aux Pelco D and P Protocols onlyAlarms Menu Relay 2 Status SET with Alarm Normally ClosedAux Number Function Menu Item Description OptionsAlarm Relays and Re-arm Time 9Sony Set MenuRelay Relay Activation Relay StateMapping to a MIC 500 Series Camera Function Exposure Shutter Priority 4 SET ShutterNumber Function ValueSetting Values Available Setting OptionsOn / OFF Aperture Reset / Plus 1 / Minus Aperture Set Low Lux Brightness Value Iris Setting Gain Setting Exposure Comp Value Iris Setting Gain Setting Focus Pos Focus DistanceIris Value Iris Setting Gain Value Gain SettingCaptions Menu Shutter Value Shutter Speed10.1 Default Caption 10.2 Preset Captions10.4Setting Captions 10.3 Sector CaptionsBlank Single Blank Save Single Save Sector /4 Sector Caption11.2Setting the Privacy Zones Privacy Menu11.1 Mask / Clear Whole Menu Item OptionsPot Test Menu 13MIC Information MenuGoto Preset Mapping Sony SET Current MIC Settings Auto Alarm OFF Multi Alarm Alarm RearmWipe Mode Normal WASH-WIPE OFF Control Card Data Serial Issue 8A14Set User Access Menu 13.1 MIC Information MenusSetting Default Value 14.1 Factory DefaultsOSD OFF Help Menu 16Self DiagnosisSupport USA EmeaAppendices MIC 500 Series Aux ControlsPreset Number Learn and Go to Preset Function MIC 500 Preset ControlsPreset Number Go To / Shot Preset Function Preset Number Learn Preset Function MIC 500 Model Numbers and Descriptions Model No DescriptionPage Bosch Security Systems, Inc
Related manuals
Manual 8 pages 56.48 Kb