Bosch Appliances 500 user manual Blank Single Blank Save Single Save, Sector /4 Sector Caption

Page 44

44 en Navigating the Menus

MIC Series 500 Camera

 

 

string, or go back to the menu screen to save or discard the changes. The characters available are as follows: 0123456789-.: ABCDEFGHIJKLMNOPQRSTUVWXYZ

If the caption is cleared (i.e., all spaces), the following is displayed: “:::: NO CAPTION ::::.” This disappears as soon as 1 or more of the characters are set.

Note: Adding caption functions to the camera may cause slight control delays or overshoots

on presets.

 

 

..CAPTIONS..

 

 

CAPTION STATUS

ON

CAPTION MODE PRESET

V POSITION

 

3

H POSITION

CENTER

COLOUR

WHITE

SETUP NORMAL CAPTION SETUP PRESET CAPTION

..NORMAL CAPTION..

SET CAPTION:

::::NO CAPTION::::

BLANK NORMAL CAPTION SET NORMAL CAPTION

..PRESET CAPTION..

PRESET NO.

1

GOTO PRESET SET CAPTION

::::NO CAPTION::::

BLANK SINGLE BLANK 1-64

SAVE SINGLE SAVE 1-64

1.The Preset Caption menu works in much the same way. There is an extra option to set the preset number with which the caption will be saved, and a few additional save or clear options. Blank Single or Save Single will clear or save the caption for the preset selected under the Preset No. option. Blank 1-64 or Save 1-64 performs the same process but to every preset available. If “- -” is entered into the preset caption at any point, then the preset number is inserted. A quick way to set this up is to save “PRESET - -” to all presets.

2.Sector Captions require 3 details. The first is the sector number, which each number relates to a different caption, of which 64 are available. Then, the start and end of the sector in degrees must be defined. They can overlap, but the sector being overwritten takes on the latest value. The caption is entered in the same way as above and saved in the same way. One extra feature on this page is the View Sector Table which opens up a set of 4 pages displaying the number of each sector 1 to 64 and the sector (caption) number associated with it. This is only for viewing purposes so there are no settings available on these pages. A left command moves the focus back to the Sector Captions page.

..SECTOR CAPTION..

 

SECTOR NO.

1

START: DEGREES

0

END : DEGREES

0

SET CAPTION

 

::::NO CAPTION::::

BLANK SECTOR CAPTION SET SECTOR CAPTION VIEW SECTOR TABLE

..SECTOR TABLE 1/4..

SECTOR - CAPTION

01-01 02-01 03-01

04-01 05-01 06-01

07-01 08-01 09-01

10-01 11-01 12-01

13-01 14-01 15-01

16-01

..SECTOR TABLE 2/4..

SECTOR - CAPTION

17-01 18-01 19-01

20-01 21-01 22-01

23-01 24-01 25-01

26-01 27-01 28-01

29-01 30-01 31-01

32-01

F.01U.173.601 2.0 2010.11

User’s Manual

Bosch Security Systems, Inc.

Image 44
Contents MIC Series 500 Camera Page Table of Contents Appendices 1Safety Important Safety InstructionsSafety Precautions Important Notices Coax groundingFCC & Ices Information A. and Canadian Models OnlyInformations FCC ET Ices DisclaimerCopyright TrademarksCustomer Support and Service Parts List UnpackingAdditional Tools Required Quantity Part1Features 2Power3Description 3Video4Mounting Part DescriptionAdjusting the MIC 500 Series Camera Pan body fixing screwsCanting in progress Adjusting the Rain Shield for Inverted Operation Remove screwsMounting the MIC 500 Series Camera Electrical Connections Earthing the MIC 500 Series CameraLightning Protection 13 Composite cable before connection Red Navigating the Menus Menu Item Description Exit1MIC Setups Menu Available only via the menu see .1.1 Config Mode,Setting Options Default ON/OFFTour ON/OFF OSDActivate Feature Menu 3Preset Tour MenuConfig Mode Image Flip Pan Reverse Tilt Reverse PrivacyRandom Tours Tour Setting ValueCreate/Modify Tour Tour Point Preset Position Dwell Time Pattern Tour MenuRecording a Pattern Tour Preview TourGoto Preset 5Presets MenuLearn Preset 6Communications Menu Manual ControlAdvanced Setups Menu Menu Item Description Options DefaultWipe Mode INTWipes Hour AutoFactory Defaults Re-map Pelco Aux Pelco D and P Protocols onlyAlarms Menu Relay 2 Status SET with Alarm Normally ClosedAux Number Function Menu Item Description OptionsAlarm Relays and Re-arm Time 9Sony Set MenuRelay Relay Activation Relay StateMapping to a MIC 500 Series Camera Function Exposure Shutter Priority 4 SET ShutterNumber Function ValueOn / OFF Setting OptionsSetting Values Available Aperture Reset / Plus 1 / Minus Aperture Set Low Lux Brightness Value Iris Setting Gain Setting Exposure Comp Value Iris Setting Gain Setting Focus Pos Focus DistanceIris Value Iris Setting Gain Value Gain SettingCaptions Menu Shutter Value Shutter Speed10.1 Default Caption 10.2 Preset Captions10.4Setting Captions 10.3 Sector CaptionsBlank Single Blank Save Single Save Sector /4 Sector Caption11.2Setting the Privacy Zones Privacy Menu11.1 Mask / Clear Whole Menu Item OptionsPot Test Menu 13MIC Information MenuGoto Preset Mapping Sony SET Current MIC Settings Auto Alarm OFF Multi Alarm Alarm RearmWipe Mode Normal WASH-WIPE OFF Control Card Data Serial Issue 8A14Set User Access Menu 13.1 MIC Information MenusOSD OFF 14.1 Factory DefaultsSetting Default Value Help Menu 16Self DiagnosisSupport USA EmeaAppendices MIC 500 Series Aux ControlsPreset Number Go To / Shot Preset Function MIC 500 Preset ControlsPreset Number Learn and Go to Preset Function Preset Number Learn Preset Function MIC 500 Model Numbers and Descriptions Model No DescriptionPage Bosch Security Systems, Inc
Related manuals