Bosch Appliances user manual Appendices, MIC 500 Series Aux Controls

Page 51

MIC Series 500 Camera en 51

A

Appendices

 

A.1

MIC 500 Series Aux Controls

 

The following table identifies the Auxiliary (Aux) codes of a MIC running Bosch protocol.

 

Table 1.1

 

 

 

 

 

 

Au

Setting

Values Available

 

x

 

 

 

 

 

 

 

2

Auto Pan

On: Starts Auto Pan between Scan Limits.

 

 

 

Tilt can be adjusted.

 

 

 

Off: Stops Auto Pan.

 

 

 

 

 

3

Iris Control

On: Iris Auto

 

 

 

Off: Iris Manual

 

 

 

 

 

4

Focus Control

On: Focus Auto

 

 

 

Off: Focus Manual

 

 

 

 

 

7

Plays Pre-position Tour 2

On: Starts Tour 2

 

 

 

Off: Stops Tour 2

 

 

 

 

 

8

Plays Pre-position Tour 1

On: Starts Tour 1

 

 

 

Off: Stops Tour 1

 

 

 

 

 

9

Inactive Home Return

On: Toggles between Return Home (Preset 99) or

 

 

 

Return Pre-position Tour (Inactivity after 300 seconds.)

 

 

 

Off: Inactive Home Return OFF

 

 

 

 

 

50

Play Pattern Tour 1

On: Plays Pattern 1

 

 

 

Off: Stops playing Pattern 1

 

 

 

 

 

52

Play Pattern Tour 2

On: Plays Pattern 2

 

 

 

Off: Stops playing Pattern 2

 

 

 

 

 

100

Record Pattern Tour 1

On: Records Pattern 1

 

 

 

Off: Stops recording Pattern 1

 

 

 

 

 

101

Record Pattern Tour 2

On: Records Pattern 2

 

 

 

Off: Stops recording Pattern 2

 

 

 

 

 

246

Fast Address Stage 1

On: Continues to Stage 2 in Fast address reprogram

 

 

 

Off: Cancels fast address reprogram

 

 

 

 

 

292

Fast Address Stage 2

On: Continues to Stage 3, which requires controller to move

 

 

 

to new address and “PRESS ON 1 ENTER”

 

 

 

Off: Cancels fast address reprogram

 

 

 

 

 

401

Wiper

On: Closes Wiper Relay

 

 

 

Off: Opens Wipe Relay

 

 

 

 

 

402

Washer

On: Closes Washer Relay (Wipes if washwipe is enabled)

 

 

 

Off: Opens Washer Relay

 

 

 

 

 

417

Protocol Change Stage 1

Continues to Stage 2

 

 

 

 

 

418

Protocol Change Stage 2

Takes next Aux as Protocol and Address Byte

 

 

 

 

 

420

On Screen menu

Displays On Screen Menu

 

 

 

 

Bosch Security Systems, Inc.

User’s Manual

F.01U.173.601 2.0 2010.11

Image 51
Contents MIC Series 500 Camera Page Table of Contents Appendices Important Safety Instructions 1SafetySafety Precautions Coax grounding Important NoticesA. and Canadian Models Only FCC & Ices InformationDisclaimer Informations FCC ET IcesTrademarks CopyrightCustomer Support and Service Quantity Part Parts ListUnpacking Additional Tools Required3Video 1Features2Power 3DescriptionPart Description 4MountingPan body fixing screws Adjusting the MIC 500 Series CameraCanting in progress Remove screws Adjusting the Rain Shield for Inverted OperationMounting the MIC 500 Series Camera Earthing the MIC 500 Series Camera Lightning ProtectionElectrical Connections 13 Composite cable before connection Red Navigating the Menus Exit Menu Item DescriptionAvailable only via the menu see .1.1 Config Mode, 1MIC Setups MenuON/OFF OSD Setting Options DefaultON/OFF TourImage Flip Pan Reverse Tilt Reverse Privacy Activate Feature Menu3Preset Tour Menu Config ModeTour Setting Value Create/Modify TourRandom Tours Preview Tour Tour Point Preset Position Dwell TimePattern Tour Menu Recording a Pattern Tour5Presets Menu Learn PresetGoto Preset Manual Control 6Communications MenuMenu Item Description Options Default Advanced Setups MenuHour Auto Wipe ModeINT WipesRe-map Pelco Aux Pelco D and P Protocols only Factory DefaultsMenu Item Description Options Alarms MenuRelay 2 Status SET with Alarm Normally Closed Aux Number FunctionRelay State Alarm Relays and Re-arm Time9Sony Set Menu Relay Relay ActivationFunction Value Mapping to a MIC 500 Series Camera FunctionExposure Shutter Priority 4 SET Shutter NumberSetting Options Setting Values AvailableOn / OFF Aperture Reset / Plus 1 / Minus Aperture Set Low Lux Brightness Value Iris Setting Gain Setting Focus Pos Focus Distance Exposure Comp Value Iris Setting Gain SettingGain Value Gain Setting Iris Value Iris SettingShutter Value Shutter Speed Captions Menu10.3 Sector Captions 10.1 Default Caption10.2 Preset Captions 10.4Setting CaptionsSector /4 Sector Caption Blank Single Blank Save Single SaveMenu Item Options 11.2Setting the Privacy ZonesPrivacy Menu 11.1 Mask / Clear Whole13MIC Information Menu Pot Test MenuControl Card Data Serial Issue 8A Goto Preset Mapping Sony SETCurrent MIC Settings Auto Alarm OFF Multi Alarm Alarm Rearm Wipe Mode Normal WASH-WIPE OFF13.1 MIC Information Menus 14Set User Access Menu14.1 Factory Defaults Setting Default ValueOSD OFF Emea Help Menu16Self Diagnosis Support USAMIC 500 Series Aux Controls AppendicesMIC 500 Preset Controls Preset Number Learn and Go to Preset FunctionPreset Number Go To / Shot Preset Function Preset Number Learn Preset Function Model No Description MIC 500 Model Numbers and DescriptionsPage Bosch Security Systems, Inc
Related manuals
Manual 8 pages 56.48 Kb