5.5.3

Manual Control

 

The MANUAL CONTROL feature enables the user to manually control the unit for ten (10)

 

seconds while setting a preset position. A time remaining caption counts down at the top of

 

the screen. At the end of the countdown, the unit stops in its current position. If more

 

movement is required, press right on the Manual Control. This allows the user an additional

 

ten (10) seconds of manual control.

5.6Communications Menu

The communications page provides the selection of the MIC Address, Protocol and Baud Rate. Once modified, the settings only take effect once the menu has been exited and the confirmation page has been accepted. The address field allows values in the range 1 to 254, this will be carried over between protocols.

The MIC 500 Series Camera provides twin protocol support in one release of software. The camera's operating protocol can be switched using the Cam-set or the “Protocol” setting in this menu section. The protocol pack options are: FV/Bosch (default), FV/Pelco and FV/VCL.

MAIN MENU

1/2

MIC SETUPS

ACTIVATE FEATURE

PRESET TOUR

PATTERN TOUR

PRESETS

COMMUNICATIONS

ADVANCED SETUPS

ALARMS

..COMMUNICATIONS..

ADDRESS

1

 

PROTOCOL

BOSCH

BAUD RATE

 

 

-------------------------------------------

: WARNING CHANGING :

: ANY SETTING MAY

:

: CAUSE A LOSS OF

:

: CONTROL

 

:

Menu Item

Description

 

 

ADDRESS

Allows the appropriate camera to be operated via the numerical address in the control system. The

 

address may be set locally using Cam-set. To change the address using Cam-set, enter the desired

 

address in the New Address field then, press Configure MIC Communications. The MIC

 

Communications Settings menu is displayed. Modify the settings then, press Apply (optional 1-254

 

addresses).

 

 

PROTOCOL

Enables the user to switch between the protocols in the loaded protocol pack. Options are: FV/

 

Bosch (default), FV/Pelco or FV/VCL.

 

 

BAUD RATE

Enables the user to toggle between 4800 and 9600 Baud rate. The speed at which

 

telecommunication data is transmitted, measured in bits per second (Bps).

 

 

 

The “Baud Rate” setting provides a full range of values, 1200, 2400, 4800, 9600, 19200 or

 

38400 for each protocol. Not all protocol controllers support this full range, so ensure that the

 

correct option is selected before confirming.

 

Modifying any of these parameters and then confirming the selection causes immediate loss

 

of control until the control system is reconfigured to match. If a protocol, address or baud

 

rate option is made that cannot be obtained through the control system, the camera must be

 

reset using the Configure MIC Communications function of Cam-set.

 

Modifying any of these values invokes an extra page to appear when exiting the menu. To

 

accept the changes made, move the line down to APPLY SETTINGS and press right. To ignore

 

them, press right on DISCARD SETTINGS.

F.01U.173.601 2.0 2010.11

User’s Manual

Bosch Security Systems, Inc.

Image 30
Contents MIC Series 500 Camera Page Table of Contents Appendices 1Safety Important Safety InstructionsSafety Precautions Important Notices Coax groundingFCC & Ices Information A. and Canadian Models OnlyInformations FCC ET Ices DisclaimerCopyright TrademarksCustomer Support and Service Additional Tools Required Parts ListUnpacking Quantity Part3Description 1Features2Power 3Video4Mounting Part DescriptionAdjusting the MIC 500 Series Camera Pan body fixing screwsCanting in progress Adjusting the Rain Shield for Inverted Operation Remove screwsMounting the MIC 500 Series Camera Earthing the MIC 500 Series Camera Lightning ProtectionElectrical Connections 13 Composite cable before connection Red Navigating the Menus Menu Item Description Exit1MIC Setups Menu Available only via the menu see .1.1 Config Mode,Tour Setting Options DefaultON/OFF ON/OFF OSDConfig Mode Activate Feature Menu3Preset Tour Menu Image Flip Pan Reverse Tilt Reverse PrivacyTour Setting Value Create/Modify TourRandom Tours Recording a Pattern Tour Tour Point Preset Position Dwell TimePattern Tour Menu Preview Tour5Presets Menu Learn PresetGoto Preset 6Communications Menu Manual ControlAdvanced Setups Menu Menu Item Description Options DefaultWipes Wipe ModeINT Hour AutoFactory Defaults Re-map Pelco Aux Pelco D and P Protocols onlyAux Number Function Alarms MenuRelay 2 Status SET with Alarm Normally Closed Menu Item Description OptionsRelay Relay Activation Alarm Relays and Re-arm Time9Sony Set Menu Relay StateNumber Mapping to a MIC 500 Series Camera FunctionExposure Shutter Priority 4 SET Shutter Function ValueSetting Options Setting Values AvailableOn / OFF Aperture Reset / Plus 1 / Minus Aperture Set Low Lux Brightness Value Iris Setting Gain Setting Exposure Comp Value Iris Setting Gain Setting Focus Pos Focus DistanceIris Value Iris Setting Gain Value Gain SettingCaptions Menu Shutter Value Shutter Speed10.4Setting Captions 10.1 Default Caption10.2 Preset Captions 10.3 Sector CaptionsBlank Single Blank Save Single Save Sector /4 Sector Caption11.1 Mask / Clear Whole 11.2Setting the Privacy ZonesPrivacy Menu Menu Item OptionsPot Test Menu 13MIC Information MenuWipe Mode Normal WASH-WIPE OFF Goto Preset Mapping Sony SETCurrent MIC Settings Auto Alarm OFF Multi Alarm Alarm Rearm Control Card Data Serial Issue 8A14Set User Access Menu 13.1 MIC Information Menus14.1 Factory Defaults Setting Default ValueOSD OFF Support USA Help Menu16Self Diagnosis EmeaAppendices MIC 500 Series Aux ControlsMIC 500 Preset Controls Preset Number Learn and Go to Preset FunctionPreset Number Go To / Shot Preset Function Preset Number Learn Preset Function MIC 500 Model Numbers and Descriptions Model No DescriptionPage Bosch Security Systems, Inc