APPLICABLE MODEL

This manual applies to the following model:

TS-570S:All mode multi-bander

TS-570D:HF Transceiver

Intelligent Digital Enhanced Communications System

SUPPLIED ACCESSORIES

Carefully unpack the transceiver. We recommend that you identify the items listed in the table below. In addition, it is safe to keep the box and the packing material. You may need to repack the transceiver in the future.

Accessory

Part Number

Quantity

 

 

 

Microphone

T91-0352-XX

1

 

 

 

DC power cable

E30-3157-XX

1

 

 

 

7-pin DIN plug

E07-0751-XX

1

13-pin DIN plug

E07-1351-XX

1

 

 

 

Fuse (25 A)

F05-2531-XX

1

Fuse (4 A)

F06-4027-XX

1

Instruction manual

B62-0898-XX

1

 

 

 

Schematic/block diagrams1

1

(U.S.A. and Canada only)

 

 

 

 

 

Warranty card

 

 

(U.S.A., Canada, and

1

Europe only)

 

 

 

 

 

1For other markets, schematic and block diagrams are available as options.

This transceiver is equipped with a bail on the bottom so that you can angle the transceiver. Pull the bail forward to the limit as shown:

NOTICE TO THE USER

One or more of the following statements may be applicable to this equipment.

FCC WARNING

This equipment generates or uses radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made.

INFORMATION TO THE DIGITAL DEVICE USER REQUIRED BY THE FCC

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can generate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer for technical assistance.

Image 2
Contents TS-570S Applicable Model Supplied AccessoriesAccessory Part Number Intelligent Digital Enhanced Communications SystemWriting Conventions Followed FeaturesKEY+ Power on KEY2Contents Installing Options Memory FeaturesOptional Accessories Specifications Appendix COM Connector Protocol IndexPower Lines Power SourcePower Cable Protection CleaningAPPROX. Loss dB PER 30 Meters 100 Feet InstallationAntenna Connection Correctly Matched 50 Ω LineGround Connection DC Power Supply ConnectionInstallation Lightning ProtectionRear Panel Accessory ConnectionsFront Panel RF control Fully clockwise Your First QSOSet the following as specified AF control Fully counterclockwise If Shift control Center SQL controlYour Getting Acquainted Front PanelGetting Acquainted TF-SET button UP/DOWN buttonsSplit button Clear buttonMicrophone KEY and Paddle jacks Rear PanelGND post EXT SP jackDisplay @8USB @6M.SCR@7LSB #1FSKOperating Basics Switching Power ON/OFFAdjusting Volume Selecting VFO a or VFO BSelecting a Frequency Selecting a ModeAdjusting Squelch Front Panel MeterTransmitting Selecting Transmit PowerPress PWR again to complete the setting Microphone GainMenu A/ Menu B Menu SetupWhat is a MENU? Page Page Menu Setup Cross Reference for Menu FunctionsBasic Communicating SSB TransmissionTX SIDETONE/ RX Pitch Frequency CW TransmissionBasic Communicating Auto ZERO-BEATTX Deviation Selection FM TransmissionAM Transmission Press FilterTF-SET Transmit Frequency SET Specialized CommunicatingSPLIT-FREQUENCY Operation UP/DWNArrl 10-METER Band Plan FM Repeater OperationSpecialized Communicating Mode/ActivitySpecialized Communicating Selecting Subtone Frequency When you are calledWhen you make a call Continuous or Burst SUBTONES?Rtty Frequencies Digital OperationRtty Frequency Shift Keying Iaru Region A./CanadaPacket Frequencies Mode MeaningMode Data Rate Europe/AfricaSlow Scan TV/ Facsimile Sstv FrequenciesSelecting Your Frequency Communicating AidsReceiving RX Equalizer RIT Receive Incremental TuningCommunicating Aids AGC Automatic Gain ControlVOX VOICE-OPERATED Transmit Microphone Input LevelXIT Transmit Incremental Tuning Communicating Aids Speech ProcessorEqualizing Transmit Audio SSB/FM/AM Transmit InhibitChanging Transmit Bandwidth SSB/AM BandwidthCW BREAK-IN Auto WeightingReversible Auto Weighting Electronic KeyerCW Message Memory Changing LOCKED-WEIGHTBUG KEY Function Noise Blanker Rejecting InterferenceIf Filter If ShiftDSP Tools AttenuatorPreamplifier Rejecting InterferenceNoise Reduction Beat CancelSetting NR2 Time Constant CW/ FSK ModesStoring Data in Memory Memory FeaturesConventional Memory Simplex ChannelsMemory Recall Memory FeaturesSplit-Frequency Channels Memory Recall and ScrollMemory-VFO Split Operation Memory ScrollTemporary Frequency Changes To use a memory channel for receivingChannel Channel Transfer Memory Features Memory TransferMemory VFO Transfer Erasing Memory Channels Full ResetStoring Frequency Ranges Confirming Start/End FrequenciesVOX ON/OFF Storing Into Quick MemoryMemory Channel Lockout RIT ON/OFF XIT ON/OFFQuick Memory VFO Transfer Memory Features Recalling Quick MemoryTemporary Frequency Changes Scan Hold ScanProgram Scan Transceiver provides the following types of ScanALL-CHANNEL Scan Memory ScanScan Group ScanOperator Conveniences Microprocessor ResetSwitching ANT 1/ ANT Frequency Lock FunctionProgram Function Button Beep FunctionDisplay Dimmer Quick Data Transfer Setting UPUsing Quick Transfer Operator ConveniencesComputer Control Using a TransverterMenu Setting Communication ParametersAT Tune again PresettingAutomatic Antenna Tuner Message Playback DRU-3A Digital Recording UnitOptional Recording MessagesChanging Inter-message Interval Changing VolumeSending Messages Menu New ModeSteps VoicePC-1A Optional AccessoriesDRU-3A PG-2ZInstalling Options Removing the Bottom CaseFilters Installing OptionsVS-3 Voice Synthesizer Unit Cut the leads of the R503 and R504 resistors SO-2 TEMPERATURE-COMPENSATEDCrystal Oscillator Tcxo Computer Compatible TransceiverLinear Amplifier Connecting Peripheral EquipmentRtty Equipment Antenna TunerMCP and TNC Pin No FunctionService MaintenanceService Note CleaningAccessing the Internal Fuse Internal AdjustmentsMaintenance Reference Frequency CalibrationFollowed TroubleshootingProblem Probable Cause Corrective Action DSP Slope LOW control orPress LSB/USB or FM/AM to Changing ReceivePress LSB/USB, CW/FSK, or Repeater Operation Communication ParametersFSK, FM Max 100 W Output powerTS-570S TS-570D Min Max 25 WSpecifications SSB, CW, FSKAppendix Hardware DescriptionControl Operation COMError Messages Computer Control CommandsAlphabetical Commands ParametersAlphabetical Command Table OFF/ONParameter Table FormatMenu Selection Table for EX Command UP/DOWNReading Command Tables Computer Control Command TablesDN UP DOWN/UP LK Frequency Lock MG MIC Gain RT RIT RX TX RX, TX VOX Function Sstv DSPVFO