Kenwood TS-570S, TS-570D, TS-570D, TS-570S instruction manual Rx Tx Rx, Tx

Page 86

APPENDIX

RX TX RX, TX

SM S-METER

Selects receive/transmit mode.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

Input

RX/TX

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

RX/TX

;

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

S-meter reading.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

S

M

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

S

M

 

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

22 S-METER

 

VALUE

Note:

In transmit mode: power meter reading

SC SCAN

SQ SQUELCH LEVEL

Sets Scan OFF/ON or reads status.

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

Input

 

S

C

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

S

C

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

 

S

C

P1

;

5

6

7

8

9

10

11 12

13

14

 

 

 

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Format

Parameter function

 

 

 

P1

1

SCAN OFF/ON

 

 

 

 

 

 

Sets or reads squelch level.

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

Input

 

S

Q

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

S

Q

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

S

Q

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

46 SQUELCH

 

LEVEL

SD SEMI BREAK-IN DELAY TIME

SR SYSTEM RESET

Sets or reads Semi Break-in delay time.

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

Input

 

S

D

 

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

S

D

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

S

D

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

49

SEMI BREAK-IN

 

 

DELAY TIME

Function

Resets the transceiver.

 

 

 

 

 

 

 

Parameter Format

Parameter function

 

 

 

 

 

 

 

 

 

 

 

 

 

P1

50

SYSTEM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RESET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

Input

S

R

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SH DSP SLOPE (HIGH CUT-OFF)

TN TONE NUMBER

Sets or reads high cut-off frequency.

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

Input

 

S

H

 

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

S

H

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

S

H

 

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

53

DSP SLOPE

 

 

(HIGH CUT-OFF)

Sets or reads subtone number (01~39).

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

Input

 

T

N

 

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

T

N

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

T

N

 

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

14 TONE NUMBER

Note:

Selecting No. 39 (1750 Hz) switches OFF the CTCSS.

SL DSP SLOPE (LOW CUT-OFF)

TO TONE

Sets or reads low cut-off frequency.

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

Input

 

S

L

 

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

S

L

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

S

L

 

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

53

DSP SLOPE

 

 

(LOW CUT-OFF)

Sets Subtone OFF/ON or reads status.

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

Input

 

T

O

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

T

O

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

T

O

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

1

TONE OFF/ON

80

Image 86
Contents TS-570S Applicable Model Supplied AccessoriesAccessory Part Number Intelligent Digital Enhanced Communications SystemWriting Conventions Followed FeaturesKEY+ Power on KEY2Contents Installing Options Memory FeaturesOptional Accessories Specifications Appendix COM Connector Protocol IndexPower Lines Power SourcePower Cable Protection CleaningAPPROX. Loss dB PER 30 Meters 100 Feet InstallationAntenna Connection Correctly Matched 50 Ω LineGround Connection DC Power Supply ConnectionInstallation Lightning ProtectionRear Panel Accessory ConnectionsFront Panel RF control Fully clockwise Your First QSOSet the following as specified AF control Fully counterclockwise If Shift control Center SQL controlYour Getting Acquainted Front PanelGetting Acquainted TF-SET button UP/DOWN buttonsSplit button Clear buttonMicrophone KEY and Paddle jacks Rear PanelGND post EXT SP jackDisplay @8USB @6M.SCR@7LSB #1FSKOperating Basics Switching Power ON/OFFAdjusting Volume Selecting VFO a or VFO BSelecting a Frequency Selecting a ModeAdjusting Squelch Front Panel MeterTransmitting Selecting Transmit PowerPress PWR again to complete the setting Microphone GainMenu A/ Menu B Menu SetupWhat is a MENU? Page Page Menu Setup Cross Reference for Menu FunctionsBasic Communicating SSB TransmissionTX SIDETONE/ RX Pitch Frequency CW TransmissionBasic Communicating Auto ZERO-BEATTX Deviation Selection FM TransmissionAM Transmission Press FilterTF-SET Transmit Frequency SET Specialized CommunicatingSPLIT-FREQUENCY Operation UP/DWNArrl 10-METER Band Plan FM Repeater OperationSpecialized Communicating Mode/ActivitySpecialized Communicating Selecting Subtone Frequency When you are calledWhen you make a call Continuous or Burst SUBTONES?Rtty Frequencies Digital OperationRtty Frequency Shift Keying Iaru Region A./CanadaPacket Frequencies Mode MeaningMode Data Rate Europe/AfricaSlow Scan TV/ Facsimile Sstv FrequenciesSelecting Your Frequency Communicating AidsReceiving RX Equalizer RIT Receive Incremental TuningCommunicating Aids AGC Automatic Gain ControlVOX VOICE-OPERATED Transmit Microphone Input LevelXIT Transmit Incremental Tuning Communicating Aids Speech ProcessorEqualizing Transmit Audio SSB/FM/AM Transmit InhibitChanging Transmit Bandwidth SSB/AM BandwidthCW BREAK-IN Auto WeightingReversible Auto Weighting Electronic KeyerCW Message Memory Changing LOCKED-WEIGHTBUG KEY Function Noise Blanker Rejecting InterferenceIf Filter If ShiftDSP Tools AttenuatorPreamplifier Rejecting InterferenceNoise Reduction Beat CancelSetting NR2 Time Constant CW/ FSK ModesStoring Data in Memory Memory FeaturesConventional Memory Simplex ChannelsMemory Recall Memory FeaturesSplit-Frequency Channels Memory Recall and ScrollMemory-VFO Split Operation Memory ScrollTemporary Frequency Changes To use a memory channel for receivingChannel Channel Transfer Memory Features Memory TransferMemory VFO Transfer Erasing Memory Channels Full ResetStoring Frequency Ranges Confirming Start/End FrequenciesVOX ON/OFF Storing Into Quick MemoryMemory Channel Lockout RIT ON/OFF XIT ON/OFFQuick Memory VFO Transfer Memory Features Recalling Quick MemoryTemporary Frequency Changes Scan Hold ScanProgram Scan Transceiver provides the following types of ScanALL-CHANNEL Scan Memory ScanScan Group ScanOperator Conveniences Microprocessor ResetSwitching ANT 1/ ANT Frequency Lock FunctionProgram Function Button Beep FunctionDisplay Dimmer Quick Data Transfer Setting UPUsing Quick Transfer Operator ConveniencesComputer Control Using a TransverterMenu Setting Communication ParametersAT Tune again PresettingAutomatic Antenna Tuner Message Playback DRU-3A Digital Recording UnitOptional Recording MessagesChanging Inter-message Interval Changing VolumeSending Messages Menu New ModeSteps VoicePC-1A Optional AccessoriesDRU-3A PG-2ZInstalling Options Removing the Bottom CaseFilters Installing OptionsVS-3 Voice Synthesizer Unit Cut the leads of the R503 and R504 resistors SO-2 TEMPERATURE-COMPENSATEDCrystal Oscillator Tcxo Computer Compatible TransceiverLinear Amplifier Connecting Peripheral EquipmentRtty Equipment Antenna TunerMCP and TNC Pin No FunctionService MaintenanceService Note CleaningAccessing the Internal Fuse Internal AdjustmentsMaintenance Reference Frequency CalibrationFollowed TroubleshootingProblem Probable Cause Corrective Action DSP Slope LOW control orPress LSB/USB or FM/AM to Changing ReceivePress LSB/USB, CW/FSK, or Repeater Operation Communication ParametersFSK, FM Max 100 W Output powerTS-570S TS-570D Min Max 25 WSpecifications SSB, CW, FSKAppendix Hardware DescriptionControl Operation COMError Messages Computer Control CommandsAlphabetical Commands ParametersAlphabetical Command Table OFF/ONParameter Table FormatMenu Selection Table for EX Command UP/DOWNReading Command Tables Computer Control Command TablesDN UP DOWN/UP LK Frequency Lock MG MIC Gain RT RIT RX TX RX, TX VOX Function Sstv DSPVFO