8 COMMUNICATING AIDS

TRANSMITTING

Delay Time

1

VOX (VOICE-OPERATED TRANSMIT)

VOX eliminates the necessity of manually switching to the transmit mode each time you want to transmit. The transceiver automatically switches to transmit when the VOX circuitry senses that you have begun speaking into the microphone.

When using VOX, develop the habit of pausing between thoughts to let the transceiver drop back to receive briefly. You will then hear if anybody wants to interrupt, plus you will have a short period to gather your thoughts before speaking again. Your listener will appreciate your consideration as well as respect your more articulate conversation.

VOX can be switched ON and OFF independently for CW and the other modes excluding FSK.

Press [VOX] to toggle VOX between ON and OFF.

If the transceiver immediately returns to receive too quickly after you stop speaking, your final word may not be transmitted. To avoid this, select the appropriate delay time that allows all of your words to be transmitted without an overly long delay after you stop speaking.

1Select SSB, FM, or AM mode.

2Switch the VOX function ON.

3Press [DELAY].

• The current setting appears. The default is 50.

2

3

4

5

• “VOX” appears when the function is ON.

4

While speaking into your microphone using your

 

 

 

normal level of voice, adjust the MULTI/CH

 

 

 

control such that the transceiver switches to

 

 

 

 

 

 

receive a brief time after you stop talking.

 

 

 

• The selectable range is 5 to 100 (150 ms to

 

 

 

3000 ms) in steps of 5, and OFF.

 

 

5

Press [DELAY] again.

Microphone Input Level

To enjoy the VOX function, take time to set the gain of the VOX circuit to the correct level. This level controls the capability of the VOX circuit to detect the presence or absence of your voice. When using CW mode, this level cannot be adjusted.

1 Select SSB, FM, or AM mode.

2 Switch the VOX function ON.

3 Access Menu No. 16.

4 While speaking into your microphone using your

normal level of voice, select different settings (default is 4) until the transceiver reliably switches to transmit each time you speak.

The selectable range is 0 to 9.

The final selection should not allow background noises near your operating position to falsely switch the transceiver from receive to transmit.

Note: Menu No. 16 is configurable even if VOX is OFF or while you are transmitting.

6

7

8

9

10

11

12

13

14

15

16

31

Image 37
Contents TS-570S Accessory Part Number Supplied AccessoriesApplicable Model Intelligent Digital Enhanced Communications SystemKEY+ Power on FeaturesWriting Conventions Followed KEY2Contents Optional Accessories Memory FeaturesInstalling Options Specifications Appendix COM Connector Protocol IndexPower Cable Protection Power SourcePower Lines CleaningAntenna Connection InstallationAPPROX. Loss dB PER 30 Meters 100 Feet Correctly Matched 50 Ω LineInstallation DC Power Supply ConnectionGround Connection Lightning ProtectionFront Panel Accessory ConnectionsRear Panel Set the following as specified AF control Your First QSORF control Fully clockwise Fully counterclockwise If Shift control Center SQL controlYour Front Panel Getting AcquaintedGetting Acquainted Split button UP/DOWN buttonsTF-SET button Clear buttonMicrophone GND post Rear PanelKEY and Paddle jacks EXT SP jackDisplay @7LSB @6M.SCR@8USB #1FSKAdjusting Volume Switching Power ON/OFFOperating Basics Selecting VFO a or VFO BAdjusting Squelch Selecting a ModeSelecting a Frequency Front Panel MeterPress PWR again to complete the setting Selecting Transmit PowerTransmitting Microphone GainWhat is a MENU? Menu SetupMenu A/ Menu B Page Page Cross Reference for Menu Functions Menu SetupSSB Transmission Basic CommunicatingBasic Communicating CW TransmissionTX SIDETONE/ RX Pitch Frequency Auto ZERO-BEATAM Transmission FM TransmissionTX Deviation Selection Press FilterSPLIT-FREQUENCY Operation Specialized CommunicatingTF-SET Transmit Frequency SET UP/DWNSpecialized Communicating FM Repeater OperationArrl 10-METER Band Plan Mode/ActivityWhen you make a call When you are calledSpecialized Communicating Selecting Subtone Frequency Continuous or Burst SUBTONES?Rtty Frequency Shift Keying Digital OperationRtty Frequencies Iaru Region A./CanadaMode Data Rate Mode MeaningPacket Frequencies Europe/AfricaSstv Frequencies Slow Scan TV/ FacsimileReceiving Communicating AidsSelecting Your Frequency Communicating Aids RIT Receive Incremental TuningRX Equalizer AGC Automatic Gain ControlMicrophone Input Level VOX VOICE-OPERATED TransmitCommunicating Aids Speech Processor XIT Transmit Incremental TuningChanging Transmit Bandwidth SSB/AM Transmit InhibitEqualizing Transmit Audio SSB/FM/AM BandwidthReversible Auto Weighting Auto WeightingCW BREAK-IN Electronic KeyerBUG KEY Function Changing LOCKED-WEIGHTCW Message Memory If Filter Rejecting InterferenceNoise Blanker If ShiftPreamplifier AttenuatorDSP Tools Rejecting InterferenceSetting NR2 Time Constant Beat CancelNoise Reduction CW/ FSK ModesConventional Memory Memory FeaturesStoring Data in Memory Simplex ChannelsSplit-Frequency Channels Memory FeaturesMemory Recall Memory Recall and ScrollTemporary Frequency Changes Memory ScrollMemory-VFO Split Operation To use a memory channel for receivingMemory VFO Transfer Memory Features Memory TransferChannel Channel Transfer Storing Frequency Ranges Full ResetErasing Memory Channels Confirming Start/End FrequenciesMemory Channel Lockout Storing Into Quick MemoryVOX ON/OFF RIT ON/OFF XIT ON/OFFTemporary Frequency Changes Memory Features Recalling Quick MemoryQuick Memory VFO Transfer Program Scan ScanScan Hold Transceiver provides the following types of ScanScan Memory ScanALL-CHANNEL Scan Group ScanSwitching ANT 1/ ANT Microprocessor ResetOperator Conveniences Frequency Lock FunctionDisplay Dimmer Beep FunctionProgram Function Button Using Quick Transfer Setting UPQuick Data Transfer Operator ConveniencesMenu Setting Using a TransverterComputer Control Communication ParametersAutomatic Antenna Tuner PresettingAT Tune again Optional DRU-3A Digital Recording UnitMessage Playback Recording MessagesSending Messages Changing VolumeChanging Inter-message Interval Steps New ModeMenu VoiceDRU-3A Optional AccessoriesPC-1A PG-2ZRemoving the Bottom Case Installing OptionsVS-3 Voice Synthesizer Unit Installing OptionsFilters Crystal Oscillator Tcxo SO-2 TEMPERATURE-COMPENSATEDCut the leads of the R503 and R504 resistors Compatible Transceiver ComputerRtty Equipment Connecting Peripheral EquipmentLinear Amplifier Antenna TunerPin No Function MCP and TNCService Note MaintenanceService CleaningMaintenance Internal AdjustmentsAccessing the Internal Fuse Reference Frequency CalibrationProblem Probable Cause Corrective Action TroubleshootingFollowed DSP Slope LOW control orPress LSB/USB, CW/FSK, or Changing ReceivePress LSB/USB or FM/AM to Communication Parameters Repeater OperationTS-570S TS-570D Max 100 W Output powerFSK, FM Min Max 25 WSSB, CW, FSK SpecificationsControl Operation Hardware DescriptionAppendix COMAlphabetical Commands Computer Control CommandsError Messages ParametersOFF/ON Alphabetical Command TableFormat Parameter TableUP/DOWN Menu Selection Table for EX CommandComputer Control Command Tables Reading Command TablesDN UP DOWN/UP LK Frequency Lock MG MIC Gain RT RIT RX TX RX, TX VOX Function VFO DSPSstv