Kenwood TS-570S, TS-570D VS-3 Voice Synthesizer Unit, Filters, Installing Options

Page 64

1

2

3

4

5

6

7

8

9

14 INSTALLING OPTIONS

VS-3 VOICE SYNTHESIZER UNIT

3 Remove the 2 screws from the OPTION FILTER

 

section of the transceiver PC board.

CAUTION: SWITCH OFF THE POWER AND UNPLUG THE DC

POWER CABLE BEFORE BEGINNING INSTALLATION.

1 Remove the bottom case (8 screws).

2 Hold the VS-3 unit with the component side facing inward, and insert the VS-3 connector into the transceiver CN16 connector.

Component side

VS-3

CN16

4 Align the pins of the transceiver CN8 and CN9 connectors with the two connectors on the filter.

• Take care to properly align the pins.

Filter

3 Replace the bottom case (8 screws).

Note: The VR8 allows you to adjust the volume for voice announcement. Use only when the volume level is too low or too high.

CN8

CN9

VR8

5 While holding the filter, carefully push down until the filter snaps into place.

10

11

12

13

YK-88C-1/ YK-88CN-1/ YK-88SN-1

FILTERS

CAUTION: SWITCH OFF THE POWER AND UNPLUG THE DC POWER CABLE BEFORE BEGINNING INSTALLATION.

1Remove the 2 screws from the bottom cover of the

transceiver.

Bottom cover

6Re-install the 2 screws that you removed in step 3.

7Replace the bottom cover (2 screws).

Note: After installing the filter, be sure to select the appropriate setting in Menu No. 46; otherwise the filter will not function.

14

15

16

2Remove the bottom cover.

58

Image 64
Contents TS-570S Supplied Accessories Accessory Part NumberApplicable Model Intelligent Digital Enhanced Communications SystemFeatures KEY+ Power onWriting Conventions Followed KEY2Contents Memory Features Optional AccessoriesInstalling Options Specifications Appendix COM Connector Protocol IndexPower Source Power Cable ProtectionPower Lines CleaningInstallation Antenna ConnectionAPPROX. Loss dB PER 30 Meters 100 Feet Correctly Matched 50 Ω LineDC Power Supply Connection InstallationGround Connection Lightning ProtectionFront Panel Accessory ConnectionsRear Panel Your First QSO Set the following as specified AF controlRF control Fully clockwise Fully counterclockwise If Shift control Center SQL controlYour Getting Acquainted Front PanelGetting Acquainted UP/DOWN buttons Split buttonTF-SET button Clear buttonMicrophone Rear Panel GND postKEY and Paddle jacks EXT SP jackDisplay @6M.SCR @7LSB@8USB #1FSKSwitching Power ON/OFF Adjusting VolumeOperating Basics Selecting VFO a or VFO BSelecting a Mode Adjusting SquelchSelecting a Frequency Front Panel MeterSelecting Transmit Power Press PWR again to complete the settingTransmitting Microphone GainWhat is a MENU? Menu SetupMenu A/ Menu B Page Page Menu Setup Cross Reference for Menu FunctionsBasic Communicating SSB TransmissionCW Transmission Basic CommunicatingTX SIDETONE/ RX Pitch Frequency Auto ZERO-BEATFM Transmission AM TransmissionTX Deviation Selection Press FilterSpecialized Communicating SPLIT-FREQUENCY OperationTF-SET Transmit Frequency SET UP/DWNFM Repeater Operation Specialized CommunicatingArrl 10-METER Band Plan Mode/ActivityWhen you are called When you make a callSpecialized Communicating Selecting Subtone Frequency Continuous or Burst SUBTONES?Digital Operation Rtty Frequency Shift KeyingRtty Frequencies Iaru Region A./CanadaMode Meaning Mode Data RatePacket Frequencies Europe/AfricaSlow Scan TV/ Facsimile Sstv FrequenciesReceiving Communicating AidsSelecting Your Frequency RIT Receive Incremental Tuning Communicating AidsRX Equalizer AGC Automatic Gain ControlVOX VOICE-OPERATED Transmit Microphone Input LevelXIT Transmit Incremental Tuning Communicating Aids Speech ProcessorTransmit Inhibit Changing Transmit Bandwidth SSB/AMEqualizing Transmit Audio SSB/FM/AM BandwidthAuto Weighting Reversible Auto WeightingCW BREAK-IN Electronic KeyerBUG KEY Function Changing LOCKED-WEIGHTCW Message Memory Rejecting Interference If FilterNoise Blanker If ShiftAttenuator PreamplifierDSP Tools Rejecting InterferenceBeat Cancel Setting NR2 Time ConstantNoise Reduction CW/ FSK ModesMemory Features Conventional MemoryStoring Data in Memory Simplex ChannelsMemory Features Split-Frequency ChannelsMemory Recall Memory Recall and ScrollMemory Scroll Temporary Frequency ChangesMemory-VFO Split Operation To use a memory channel for receivingMemory VFO Transfer Memory Features Memory TransferChannel Channel Transfer Full Reset Storing Frequency RangesErasing Memory Channels Confirming Start/End FrequenciesStoring Into Quick Memory Memory Channel LockoutVOX ON/OFF RIT ON/OFF XIT ON/OFFTemporary Frequency Changes Memory Features Recalling Quick MemoryQuick Memory VFO Transfer Scan Program ScanScan Hold Transceiver provides the following types of ScanMemory Scan ScanALL-CHANNEL Scan Group ScanMicroprocessor Reset Switching ANT 1/ ANTOperator Conveniences Frequency Lock FunctionDisplay Dimmer Beep FunctionProgram Function Button Setting UP Using Quick TransferQuick Data Transfer Operator ConveniencesUsing a Transverter Menu SettingComputer Control Communication ParametersAutomatic Antenna Tuner PresettingAT Tune again DRU-3A Digital Recording Unit OptionalMessage Playback Recording MessagesSending Messages Changing VolumeChanging Inter-message Interval New Mode StepsMenu VoiceOptional Accessories DRU-3APC-1A PG-2ZInstalling Options Removing the Bottom CaseVS-3 Voice Synthesizer Unit Installing OptionsFilters Crystal Oscillator Tcxo SO-2 TEMPERATURE-COMPENSATEDCut the leads of the R503 and R504 resistors Computer Compatible TransceiverConnecting Peripheral Equipment Rtty EquipmentLinear Amplifier Antenna TunerMCP and TNC Pin No FunctionMaintenance Service NoteService CleaningInternal Adjustments MaintenanceAccessing the Internal Fuse Reference Frequency CalibrationTroubleshooting Problem Probable Cause Corrective ActionFollowed DSP Slope LOW control orPress LSB/USB, CW/FSK, or Changing ReceivePress LSB/USB or FM/AM to Repeater Operation Communication ParametersMax 100 W Output power TS-570S TS-570DFSK, FM Min Max 25 WSpecifications SSB, CW, FSKHardware Description Control OperationAppendix COMComputer Control Commands Alphabetical CommandsError Messages ParametersAlphabetical Command Table OFF/ONParameter Table FormatMenu Selection Table for EX Command UP/DOWNReading Command Tables Computer Control Command TablesDN UP DOWN/UP LK Frequency Lock MG MIC Gain RT RIT RX TX RX, TX VOX Function VFO DSPSstv