Kenwood TS-570D, TS-570S, TS-570S, TS-570D instruction manual LK Frequency Lock

Page 83

APPENDIX

FW FILTER WIDTH

KS KEYER SPEED

Sets or reads filter bandwidth.

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

Input

 

F

W

 

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

F

W

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

 

F

W

3

4

P1

6

;

8

9

10

11 12

13

14

 

 

 

1

2

5

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Format

Parameter function

 

 

 

 

P1

 

38

FILTER WIDTH

 

 

 

 

 

Note:

 

 

SSB/AM/FM

CW

 

 

0000~0079:

50 Hz

0000: Narrow

0080~0099:

80 Hz

0001~: Wide

0100~0149:

100 Hz

 

 

0150~0199:

150 Hz FSK

 

0200~0299:

200 Hz 0000~0499: 250 Hz

0300~0399:

300 Hz 0500~0999: 500 Hz

0400~0499:

400 Hz 1000~1499: 1000 Hz

0500~0599:

500 Hz 1500~

: 1500 Hz

0600~0999:

600 Hz

 

 

1000~1999:

1000 Hz

 

2000~

: 2000 Hz

 

 

 

 

 

 

Sets or reads keying speed while using the KY command.

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

Input

 

K

S

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

K

S

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

K

S

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Format

Parameter function

 

 

 

P1

42

KEYER SPEED

 

 

 

 

 

 

GT

AUTO GAIN CONTROL TIME CONSTANT

KY

CW KEYING

Sets or reads AGC time constant.

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

Input

G

T

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

G

T

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

G

T

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

39 AGC TIME

CONSTANT

Note:

When in FM mode, the transceiver

returns “”.

Converts input characters into Morse code.

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

 

4

5

6

7

8

9

10

11

12

13

14

 

 

Set

 

 

K

Y

 

 

 

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

16

17

18

19

20

21 22

23 24

25

26 27

28

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

 

4

5

6

7

8

9

10

11 12

13

14

 

 

K

Y

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

43

KEYER MESSAGE

P2

44

KEYER BUFFER

Note: The Set command requires a “ ” (ASCII code 20h) in the third byte position. Insert “ ” for bytes that have no characters to make a 28-byte fixed length command.

The “ ” bytes will not send any character.

Supported characters include: Letters, numbers, " ' (( )) ( ) + ,–

. / : = ?

ID IDENTIFICATION

Reads Model number of the transceiver.

Parameter Format Parameter function

Function

 

 

 

 

 

 

 

 

 

 

 

P1

16

MODEL NUMBER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

K

Y

P2

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

15

16

17

18

19

20

21 22

23 24

25

26 27

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

30 31

32

33

34

35 36

37

38 39

40 41

42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Up to 24 characters can be converted as one sentence at one time. The subsequent sentence must be keyed after the current conversion is completed.

Input

Set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LK FREQUENCY LOCK

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

I

D

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

I

D

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IF

INFORMATION

 

 

 

 

 

 

 

 

 

 

Reads status of the transceiver.

Parameter Format Parameter function

Function

 

 

 

 

 

 

 

 

 

 

 

P1

4

FREQUENCY

 

 

 

 

 

 

 

 

 

 

 

P2

NOT USED

 

 

 

 

 

 

 

 

 

 

 

P3

5

RIT/XIT FREQUENCY

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11 12

13 14

P4

1

RIT OFF/ON

Sets Frequency Lock OFF/ON or reads status.

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

Input

 

L

K

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

L

K

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

L

K

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

1

LOCK OFF/ON

Input

Set

 

 

 

 

P5

1

XIT OFF/ON

 

 

 

 

 

 

 

 

 

 

 

P6

NOT USED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LM LOAD MESSAGE

 

Read

1

2

3

4

5

6

7

8

9

 

10

11 12

13 14

P7

7

MEMORY CHANNEL

 

I

F

;

 

 

 

 

 

 

 

 

 

 

 

 

 

P8

11

TX/RX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P9

2

MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

 

10

11

12

13

14

 

 

 

P10

3

FUNCTION

 

 

I

F

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

P11

1

SCAN OFF/ON

Output

Answer

15 16 17 18 19 20 21 22 23 24

25

26 27

28

P12

1

SPLIT OFF/ON

 

 

 

 

 

 

P3

 

 

 

 

P4

P5

 

P7

P13

1

TONE OFF/ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P14

14

TONE NUMBER

 

 

29

30 31

32

33

34 35 36

37

 

38

39

40 41

42

 

 

 

P15

NOT USED

 

 

P8

P9

P10

P11

P12

P13

P14

 

 

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IS IF SHIFT

Function

DRU or CW message recording

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

Input

 

L

M

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

L

M

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

L

M

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

45 LOAD

MESSAGE

Sets or reads IF shift.

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

Input

I

S

P1

 

 

P2

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

 

I

S

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11 12

13

14

 

 

 

 

 

 

 

 

I

S

P1

 

 

P2

 

;

 

 

 

 

 

 

Parameter Format Parameter function

P1

40

IF SHIFT

 

 

DIRECTION

P2

41

IF SHIFT

 

 

FREQUENCY

Note:

If P2 is positive or zero, P1 can be “+” or “”.

77

Image 83
Contents TS-570S Intelligent Digital Enhanced Communications System Supplied AccessoriesAccessory Part Number Applicable ModelKEY2 FeaturesKEY+ Power on Writing Conventions FollowedContents Specifications Appendix COM Connector Protocol Index Memory FeaturesOptional Accessories Installing OptionsCleaning Power SourcePower Cable Protection Power LinesCorrectly Matched 50 Ω Line InstallationAntenna Connection APPROX. Loss dB PER 30 Meters 100 FeetLightning Protection DC Power Supply ConnectionInstallation Ground ConnectionRear Panel Accessory ConnectionsFront Panel Fully counterclockwise If Shift control Center SQL control Your First QSOSet the following as specified AF control RF control Fully clockwiseYour Front Panel Getting AcquaintedGetting Acquainted Clear button UP/DOWN buttonsSplit button TF-SET buttonMicrophone EXT SP jack Rear PanelGND post KEY and Paddle jacksDisplay #1FSK @6M.SCR@7LSB @8USBSelecting VFO a or VFO B Switching Power ON/OFFAdjusting Volume Operating BasicsFront Panel Meter Selecting a ModeAdjusting Squelch Selecting a FrequencyMicrophone Gain Selecting Transmit PowerPress PWR again to complete the setting TransmittingMenu A/ Menu B Menu SetupWhat is a MENU? Page Page Cross Reference for Menu Functions Menu SetupSSB Transmission Basic CommunicatingAuto ZERO-BEAT CW TransmissionBasic Communicating TX SIDETONE/ RX Pitch FrequencyPress Filter FM TransmissionAM Transmission TX Deviation SelectionUP/DWN Specialized CommunicatingSPLIT-FREQUENCY Operation TF-SET Transmit Frequency SETMode/Activity FM Repeater OperationSpecialized Communicating Arrl 10-METER Band PlanContinuous or Burst SUBTONES? When you are calledWhen you make a call Specialized Communicating Selecting Subtone FrequencyIaru Region A./Canada Digital OperationRtty Frequency Shift Keying Rtty FrequenciesEurope/Africa Mode MeaningMode Data Rate Packet FrequenciesSstv Frequencies Slow Scan TV/ FacsimileSelecting Your Frequency Communicating AidsReceiving AGC Automatic Gain Control RIT Receive Incremental TuningCommunicating Aids RX EqualizerMicrophone Input Level VOX VOICE-OPERATED TransmitCommunicating Aids Speech Processor XIT Transmit Incremental TuningBandwidth Transmit InhibitChanging Transmit Bandwidth SSB/AM Equalizing Transmit Audio SSB/FM/AMElectronic Keyer Auto WeightingReversible Auto Weighting CW BREAK-INCW Message Memory Changing LOCKED-WEIGHTBUG KEY Function If Shift Rejecting InterferenceIf Filter Noise BlankerRejecting Interference AttenuatorPreamplifier DSP ToolsCW/ FSK Modes Beat CancelSetting NR2 Time Constant Noise ReductionSimplex Channels Memory FeaturesConventional Memory Storing Data in MemoryMemory Recall and Scroll Memory FeaturesSplit-Frequency Channels Memory RecallTo use a memory channel for receiving Memory ScrollTemporary Frequency Changes Memory-VFO Split OperationChannel Channel Transfer Memory Features Memory TransferMemory VFO Transfer Confirming Start/End Frequencies Full ResetStoring Frequency Ranges Erasing Memory ChannelsRIT ON/OFF XIT ON/OFF Storing Into Quick MemoryMemory Channel Lockout VOX ON/OFFQuick Memory VFO Transfer Memory Features Recalling Quick MemoryTemporary Frequency Changes Transceiver provides the following types of Scan ScanProgram Scan Scan HoldGroup Scan Memory ScanScan ALL-CHANNEL ScanFrequency Lock Function Microprocessor ResetSwitching ANT 1/ ANT Operator ConveniencesProgram Function Button Beep FunctionDisplay Dimmer Operator Conveniences Setting UPUsing Quick Transfer Quick Data TransferCommunication Parameters Using a TransverterMenu Setting Computer ControlAT Tune again PresettingAutomatic Antenna Tuner Recording Messages DRU-3A Digital Recording UnitOptional Message PlaybackChanging Inter-message Interval Changing VolumeSending Messages Voice New ModeSteps MenuPG-2Z Optional AccessoriesDRU-3A PC-1ARemoving the Bottom Case Installing OptionsFilters Installing OptionsVS-3 Voice Synthesizer Unit Cut the leads of the R503 and R504 resistors SO-2 TEMPERATURE-COMPENSATEDCrystal Oscillator Tcxo Compatible Transceiver ComputerAntenna Tuner Connecting Peripheral EquipmentRtty Equipment Linear AmplifierPin No Function MCP and TNCCleaning MaintenanceService Note ServiceReference Frequency Calibration Internal AdjustmentsMaintenance Accessing the Internal FuseDSP Slope LOW control or TroubleshootingProblem Probable Cause Corrective Action FollowedPress LSB/USB or FM/AM to Changing ReceivePress LSB/USB, CW/FSK, or Communication Parameters Repeater OperationMin Max 25 W Max 100 W Output powerTS-570S TS-570D FSK, FMSSB, CW, FSK SpecificationsCOM Hardware DescriptionControl Operation AppendixParameters Computer Control CommandsAlphabetical Commands Error MessagesOFF/ON Alphabetical Command TableFormat Parameter TableUP/DOWN Menu Selection Table for EX CommandComputer Control Command Tables Reading Command TablesDN UP DOWN/UP LK Frequency Lock MG MIC Gain RT RIT RX TX RX, TX VOX Function Sstv DSPVFO