Kenwood TS-570S, TS-570D Selecting a Mode, Adjusting Squelch, Selecting a Frequency

Page 20

4 OPERATING BASICS

1

SELECTING A MODE

Depending on which operating mode you want to select,

 

 

press the [LSB/USB], [CW/FSK], or [FM/AM] button.

 

2

The second function on each button is accessed by

again pressing the same button. For example,

repeatedly pressing [LSB/USB] toggles between LSB

 

and USB modes.

 

 

 

 

 

3

 

 

LSB

 

 

 

USB

 

 

 

CW

 

 

 

 

 

 

4

 

FSK

 

FM

 

 

 

AM

 

 

 

 

 

 

5

In SSB mode, the transceiver automatically selects LSB

 

for frequencies lower than 9.5 MHz, and selects USB for

 

9.5 MHz or higher frequencies if the Tuning control, the

 

6

MULTI/CH control, or Mic [UP]/[DWN] is used to cross

the frequency of 9.5 MHz. This is also true if using the

 

front panel [UP] or [DOWN] button when the 1 MHz

 

Step mode is used.

7

ADJUSTING SQUELCH

 

 

The purpose of squelch is to silence audio output from

8

the speaker when no signal is present. When squelch

is set correctly, you will hear sound only while a station

 

is actually being received. The point at which ambient

 

9

noise on a frequency just disappears, called the squelch

threshold, depends on the frequency.

Turn the SQL control clockwise to just eliminate the

 

 

background noise when no signal is present. Many

 

10

operators prefer leaving the squelch control fully

counterclockwise unless operating full-carrier modes

 

such as FM or AM.

 

 

 

 

 

 

 

 

11

IF SHIFT

 

SQL

 

4

6

 

 

 

 

 

 

QUICK MEMO

 

 

 

 

 

2

8

12

0

10

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

14

15

16

SELECTING A FREQUENCY

There are two simple methods to select a frequency.

AManual Tuning

Turn the Tuning control or press Mic [UP]/[DWN] to select the exact frequency.

QUICK MEMO

BDirect Frequency Entry (Keypad)

Press [ENT], then directly enter the desired frequency using the numeric keypad. For details, refer to “Direct Frequency Entry” {page 29}.

CH1 CH2 CH3

1 2 3

ANT REC FINE

4 5 6

NB AGC/TONE REV

7 8 9

F.LOCK

CLR 0 ENT

FRONT PANEL METER

The multifunction meter measures the parameters in the table below. The appropriate meters automatically become functional according to which state the transceiver is in. Peak readings for the S-meter, ALC, SWR, COMP, and PWR functions are held for a brief moment.

Scale

Display

Functional State

 

 

 

S

Received signal strength

Receive

PWR

Transmit output power

Transmit

 

 

 

ALC

Automatic level control

Transmit

 

status

 

SWR

Antenna system standing

Transmit

 

wave ratio

 

COMP

Speech compression level

Transmit plus

 

when using the Speech

SSB/AM/FM mode

 

Processor {page 32}

plus [PROC] ON

 

 

 

Note:

The COMP meter functions only when the Speech Processor is ON while using SSB, FM, or AM mode. When the COMP meter appears, the SWR meter disappears.

Peak Hold readings cannot be deactivated on this transceiver.

14

Image 20
Contents TS-570S Supplied Accessories Accessory Part NumberApplicable Model Intelligent Digital Enhanced Communications SystemFeatures KEY+ Power onWriting Conventions Followed KEY2Contents Memory Features Optional AccessoriesInstalling Options Specifications Appendix COM Connector Protocol IndexPower Source Power Cable ProtectionPower Lines CleaningInstallation Antenna ConnectionAPPROX. Loss dB PER 30 Meters 100 Feet Correctly Matched 50 Ω LineDC Power Supply Connection InstallationGround Connection Lightning ProtectionRear Panel Accessory ConnectionsFront Panel Your First QSO Set the following as specified AF controlRF control Fully clockwise Fully counterclockwise If Shift control Center SQL controlYour Getting Acquainted Front PanelGetting Acquainted UP/DOWN buttons Split buttonTF-SET button Clear buttonMicrophone Rear Panel GND postKEY and Paddle jacks EXT SP jackDisplay @6M.SCR @7LSB@8USB #1FSKSwitching Power ON/OFF Adjusting VolumeOperating Basics Selecting VFO a or VFO BSelecting a Mode Adjusting SquelchSelecting a Frequency Front Panel MeterSelecting Transmit Power Press PWR again to complete the settingTransmitting Microphone GainMenu A/ Menu B Menu SetupWhat is a MENU? Page Page Menu Setup Cross Reference for Menu FunctionsBasic Communicating SSB TransmissionCW Transmission Basic CommunicatingTX SIDETONE/ RX Pitch Frequency Auto ZERO-BEATFM Transmission AM TransmissionTX Deviation Selection Press FilterSpecialized Communicating SPLIT-FREQUENCY OperationTF-SET Transmit Frequency SET UP/DWNFM Repeater Operation Specialized CommunicatingArrl 10-METER Band Plan Mode/ActivityWhen you are called When you make a callSpecialized Communicating Selecting Subtone Frequency Continuous or Burst SUBTONES?Digital Operation Rtty Frequency Shift KeyingRtty Frequencies Iaru Region A./CanadaMode Meaning Mode Data RatePacket Frequencies Europe/AfricaSlow Scan TV/ Facsimile Sstv FrequenciesSelecting Your Frequency Communicating AidsReceiving RIT Receive Incremental Tuning Communicating AidsRX Equalizer AGC Automatic Gain ControlVOX VOICE-OPERATED Transmit Microphone Input LevelXIT Transmit Incremental Tuning Communicating Aids Speech ProcessorTransmit Inhibit Changing Transmit Bandwidth SSB/AMEqualizing Transmit Audio SSB/FM/AM BandwidthAuto Weighting Reversible Auto WeightingCW BREAK-IN Electronic KeyerCW Message Memory Changing LOCKED-WEIGHTBUG KEY Function Rejecting Interference If FilterNoise Blanker If ShiftAttenuator PreamplifierDSP Tools Rejecting InterferenceBeat Cancel Setting NR2 Time ConstantNoise Reduction CW/ FSK ModesMemory Features Conventional MemoryStoring Data in Memory Simplex ChannelsMemory Features Split-Frequency ChannelsMemory Recall Memory Recall and ScrollMemory Scroll Temporary Frequency ChangesMemory-VFO Split Operation To use a memory channel for receivingChannel Channel Transfer Memory Features Memory TransferMemory VFO Transfer Full Reset Storing Frequency RangesErasing Memory Channels Confirming Start/End FrequenciesStoring Into Quick Memory Memory Channel LockoutVOX ON/OFF RIT ON/OFF XIT ON/OFFQuick Memory VFO Transfer Memory Features Recalling Quick MemoryTemporary Frequency Changes Scan Program ScanScan Hold Transceiver provides the following types of ScanMemory Scan ScanALL-CHANNEL Scan Group ScanMicroprocessor Reset Switching ANT 1/ ANTOperator Conveniences Frequency Lock FunctionProgram Function Button Beep FunctionDisplay Dimmer Setting UP Using Quick TransferQuick Data Transfer Operator ConveniencesUsing a Transverter Menu SettingComputer Control Communication ParametersAT Tune again PresettingAutomatic Antenna Tuner DRU-3A Digital Recording Unit OptionalMessage Playback Recording MessagesChanging Inter-message Interval Changing VolumeSending Messages New Mode StepsMenu VoiceOptional Accessories DRU-3APC-1A PG-2ZInstalling Options Removing the Bottom CaseFilters Installing OptionsVS-3 Voice Synthesizer Unit Cut the leads of the R503 and R504 resistors SO-2 TEMPERATURE-COMPENSATEDCrystal Oscillator Tcxo Computer Compatible TransceiverConnecting Peripheral Equipment Rtty EquipmentLinear Amplifier Antenna TunerMCP and TNC Pin No FunctionMaintenance Service NoteService CleaningInternal Adjustments MaintenanceAccessing the Internal Fuse Reference Frequency CalibrationTroubleshooting Problem Probable Cause Corrective ActionFollowed DSP Slope LOW control orPress LSB/USB or FM/AM to Changing ReceivePress LSB/USB, CW/FSK, or Repeater Operation Communication ParametersMax 100 W Output power TS-570S TS-570DFSK, FM Min Max 25 WSpecifications SSB, CW, FSKHardware Description Control OperationAppendix COMComputer Control Commands Alphabetical CommandsError Messages ParametersAlphabetical Command Table OFF/ONParameter Table FormatMenu Selection Table for EX Command UP/DOWNReading Command Tables Computer Control Command TablesDN UP DOWN/UP LK Frequency Lock MG MIC Gain RT RIT RX TX RX, TX VOX Function Sstv DSPVFO