In addition to turning the Tuning control or pressing Mic [UP]/[DWN], there are several other ways to select your frequency. This section describes additional methods of frequency selection that may save you effort and time.

Direct Frequency Entry

When the desired frequency is far removed from the current frequency, directly entering a frequency from the numeric keypad can be the fastest method.

1 Press [ENT].

• “- - . - - - . - -” appears.

2Press numeric buttons [0] to [9] to enter the frequency you desire.

Pressing [ENT] fills the remaining un-entered digits with 0 and completes entry.

To select 1.85 MHz for example, press [0] for the 10 MHz digit (first digit), because you can also select 18.5 MHz on this transceiver.

Pressing [CLR] cancels entry and restores the previous frequency.

Note:

Some digits cannot be entered for the 10 MHz digit (first digit). Pressing one of those digits will cause that digit to be entered in the 1 MHz position.

When the 10 Hz digit (last digit) is entered, the digit 0 is entered automatically for the 1 Hz digit, and frequency entry is completed. The 1 Hz digit is not displayed.

Attempting to enter a frequency that is outside the selectable frequency range causes an alarm to be generated. The entered frequency is rejected.

When an entered frequency is accepted, RIT and XIT are switched OFF, but the RIT or XIT frequency is not changed.

After recalling memory channels 90 to 99 that have Start and End frequencies stored, the receive frequency can be changed by using Direct Frequency Entry within the programmed range.

Using 1 MHz Steps

Pressing [UP]/[DOWN] on the front panel changes Amateur bands. You can also use [UP]/[DOWN] to change operating frequencies in steps of 1 MHz.

1 Press [1MHz].

• “1MHz” appears.

2Press [UP] or [DOWN].

Holding down either button causes the function to repeat.

3To restore the original function, press [1MHz] again.

“1MHz” disappears.

If you prefer 100 kHz or 500 kHz steps instead of 1 MHz, use Menu No. 02. The default is 1 MHz.

Quick Changes

To move up or down in frequency quickly, use the MULTI/CH control. Turning this control changes the operating frequency in 10 kHz steps.

If you want to change the frequency step size, use Menu Nos. 03 and 04. Select 1 kHz, 5 kHz, 10 kHz, 12.5 kHz, 20 kHz, or 25 kHz for FM, and select 1 kHz, 5 kHz, or 10 kHz for the other modes. The default for both Menu numbers is 10 kHz.

When changing the operating frequency by using the MULTI/CH control, frequencies are rounded such that new frequencies are multiples of the frequency step size. To cancel this function, access Menu No. 05 and select OFF.

Within the AM broadcast band, the step size automatically defaults to 9 kHz (U.S.A./Canada versions: 10 kHz) for AM mode. This step size can be switched between 9 kHz and 10 kHz via Menu No. 06.

Fine Tuning

Usually, turning the Tuning control changes the frequency in steps of 10 Hz for SSB, CW, and FSK modes, and 100 Hz for FM and AM modes. However, you can also change the step size to 1 Hz for SSB, CW, and FSK modes, and to 10 Hz for FM and AM modes.

1 Press [FINE].

• “FINE” appears.

2Turn the Tuning control to select the exact frequency.

3To cancel the function, press [FINE] again.

• “FINE” disappears.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

29

Image 35
Contents TS-570S Intelligent Digital Enhanced Communications System Supplied AccessoriesAccessory Part Number Applicable ModelKEY2 FeaturesKEY+ Power on Writing Conventions FollowedContents Specifications Appendix COM Connector Protocol Index Memory FeaturesOptional Accessories Installing OptionsCleaning Power SourcePower Cable Protection Power LinesCorrectly Matched 50 Ω Line InstallationAntenna Connection APPROX. Loss dB PER 30 Meters 100 FeetLightning Protection DC Power Supply ConnectionInstallation Ground ConnectionRear Panel Accessory ConnectionsFront Panel Fully counterclockwise If Shift control Center SQL control Your First QSOSet the following as specified AF control RF control Fully clockwiseYour Front Panel Getting AcquaintedGetting Acquainted Clear button UP/DOWN buttonsSplit button TF-SET buttonMicrophone EXT SP jack Rear PanelGND post KEY and Paddle jacksDisplay #1FSK @6M.SCR@7LSB @8USBSelecting VFO a or VFO B Switching Power ON/OFFAdjusting Volume Operating BasicsFront Panel Meter Selecting a ModeAdjusting Squelch Selecting a FrequencyMicrophone Gain Selecting Transmit PowerPress PWR again to complete the setting TransmittingMenu A/ Menu B Menu SetupWhat is a MENU? Page Page Cross Reference for Menu Functions Menu SetupSSB Transmission Basic CommunicatingAuto ZERO-BEAT CW TransmissionBasic Communicating TX SIDETONE/ RX Pitch FrequencyPress Filter FM TransmissionAM Transmission TX Deviation SelectionUP/DWN Specialized CommunicatingSPLIT-FREQUENCY Operation TF-SET Transmit Frequency SETMode/Activity FM Repeater OperationSpecialized Communicating Arrl 10-METER Band PlanContinuous or Burst SUBTONES? When you are calledWhen you make a call Specialized Communicating Selecting Subtone FrequencyIaru Region A./Canada Digital OperationRtty Frequency Shift Keying Rtty FrequenciesEurope/Africa Mode MeaningMode Data Rate Packet FrequenciesSstv Frequencies Slow Scan TV/ FacsimileSelecting Your Frequency Communicating AidsReceiving AGC Automatic Gain Control RIT Receive Incremental TuningCommunicating Aids RX EqualizerMicrophone Input Level VOX VOICE-OPERATED TransmitCommunicating Aids Speech Processor XIT Transmit Incremental TuningBandwidth Transmit InhibitChanging Transmit Bandwidth SSB/AM Equalizing Transmit Audio SSB/FM/AMElectronic Keyer Auto WeightingReversible Auto Weighting CW BREAK-INCW Message Memory Changing LOCKED-WEIGHTBUG KEY Function If Shift Rejecting InterferenceIf Filter Noise BlankerRejecting Interference AttenuatorPreamplifier DSP ToolsCW/ FSK Modes Beat CancelSetting NR2 Time Constant Noise ReductionSimplex Channels Memory FeaturesConventional Memory Storing Data in MemoryMemory Recall and Scroll Memory FeaturesSplit-Frequency Channels Memory RecallTo use a memory channel for receiving Memory ScrollTemporary Frequency Changes Memory-VFO Split OperationChannel Channel Transfer Memory Features Memory TransferMemory VFO Transfer Confirming Start/End Frequencies Full ResetStoring Frequency Ranges Erasing Memory ChannelsRIT ON/OFF XIT ON/OFF Storing Into Quick MemoryMemory Channel Lockout VOX ON/OFFQuick Memory VFO Transfer Memory Features Recalling Quick MemoryTemporary Frequency Changes Transceiver provides the following types of Scan ScanProgram Scan Scan HoldGroup Scan Memory ScanScan ALL-CHANNEL ScanFrequency Lock Function Microprocessor ResetSwitching ANT 1/ ANT Operator ConveniencesProgram Function Button Beep FunctionDisplay Dimmer Operator Conveniences Setting UPUsing Quick Transfer Quick Data TransferCommunication Parameters Using a TransverterMenu Setting Computer ControlAT Tune again PresettingAutomatic Antenna Tuner Recording Messages DRU-3A Digital Recording UnitOptional Message PlaybackChanging Inter-message Interval Changing VolumeSending Messages Voice New ModeSteps MenuPG-2Z Optional AccessoriesDRU-3A PC-1ARemoving the Bottom Case Installing OptionsFilters Installing OptionsVS-3 Voice Synthesizer Unit Cut the leads of the R503 and R504 resistors SO-2 TEMPERATURE-COMPENSATEDCrystal Oscillator Tcxo Compatible Transceiver ComputerAntenna Tuner Connecting Peripheral EquipmentRtty Equipment Linear AmplifierPin No Function MCP and TNCCleaning MaintenanceService Note ServiceReference Frequency Calibration Internal AdjustmentsMaintenance Accessing the Internal FuseDSP Slope LOW control or TroubleshootingProblem Probable Cause Corrective Action FollowedPress LSB/USB or FM/AM to Changing ReceivePress LSB/USB, CW/FSK, or Communication Parameters Repeater OperationMin Max 25 W Max 100 W Output powerTS-570S TS-570D FSK, FMSSB, CW, FSK SpecificationsCOM Hardware DescriptionControl Operation AppendixParameters Computer Control CommandsAlphabetical Commands Error MessagesOFF/ON Alphabetical Command TableFormat Parameter TableUP/DOWN Menu Selection Table for EX CommandComputer Control Command Tables Reading Command TablesDN UP DOWN/UP LK Frequency Lock MG MIC Gain RT RIT RX TX RX, TX VOX Function Sstv DSPVFO