Kathrein CAP 700 manual Proper USE USE for the Intended Purpose

Page 5

PROPER USE

PROPER USE (USE FOR THE INTENDED PURPOSE)

The MobiSet 3 digital CAP 700 is designed to receive digital TV and radio programs via satellite. The automatic positioner is intended to be used as a turntable for the parabolic reflector.

The turntable can be used to receive digital TV and radio signals in the frequency range from 10.70 to 12.75 GHz; the antenna cannot receive terrestrial signals (e.g. DVB-T).

The turntable can only be used in conjunction with the UFS 740sw DVB-S receiver.

In conjunction with this receiver, the turntable provides fully automatic alignment of the parabolic reflector to receive digital satellite signals. The turntable is designed for use on stationary caravans or motor homes.

Any use other than that specified above will void the warranty or guarantee.

The following circumstances result in the loss of all warranty and liability claims towards the manufacturer:

Improper installation

Use of non-specified mounting materials, which cannot guarantee the mechanical reliability of the antenna system

Impermissible use, e.g. use of the satellite dish for storage

Structural changes or interference with the components and mounting accessories in the set, which could endanger both the mechanical and functional reliability

Improper or forcible opening of the components

Use of cleaners containing solvents, such as acetone, nitro-cellulose thinners, petrol etc.

Failure to observe installation and safety instructions in this manual

Note: The maximum permissible speed for vehicles with a CAP 700 receiver unit mounted on the roof is 130 km/h. Before commencing a journey, the satellite dish must always be lowered into horizontal position (park position).

The turntable may be operated in an ambient temperature range of -20 °C to +45 °C. Operating the system outside this range may result in malfunctions or damage to the system. When choosing the location for installation or raising the UFS 740sw, ensure there is adequate ventilation.

The system may only be installed by qualified specialist personnel!

To prevent hazards during installation, operation or when driving on public highways, the instructions and information in this manual must be strictly adhered to. Proper installation and connection of the system are pre-requisites for conformity with the corresponding standards.

This is documented in advance by the CE mark and the declaration of conformity in the appendix to this manual.

5

Image 5
Contents CAP Contents Spent batteries are special waste Foreign Language Installation MANUALS/DISPOSALDisposal Instructions Product Package Mobiset 3 CAP 700 COMPONENTS/SCOPE of DeliveryProper USE USE for the Intended Purpose Proper USEAdhesive sealant Safety Instructions Important NotesEssential information Road Traffic Licensing Regulations StVZO Power supply, fusingChecks before commencing a journey Selecting the Installation Location Installation and ConnectionRequired Tools and Equipment Unpacking and PreparationDirection of travel Ring Adhesive Installation StepsArrow in the direction of travel Recess for cable Adhesive areas between the two grooves Installation of Turntable Direction of travel Version with External Cable Gland FIG. F Brief Instructions for Installing the Turntable Tightening torque 6 Nm Suspended Installation Installation on a Fixed Flat Surface They must not be reversed or the unit will not function Installation and Connection Connection Example for 12 V Battery Connection Reception RANGE/FOOTPRINT Dismantling for Servicing Address of the Service CentreESC DismantlingPolarisation Setting Polarisation SettingAstra Eutelsat Setting Operations Safety NotesView after installation +45 Manual Lowering to Park Position Manual Lowering Dimensions MM Technical DataTechnical Data Type CAP Materials/preparation and company designation Sikaflex 291 Safety Data SheetComposition/data on components Potential hazardsMeasures if inadvertently released Measures for fire fightingHandling and storage Exposure limitation and personal protective equipmentStability and reactivity Physical and chemical characteristicsEcological data Toxicology data SensitisationDisposal instructions Transport dataOther data Sikaflex-291 Ikaflex Sikaflex 291 Technical Data SheetChemical Stability CAP 700 Operating Manual Remote Control Important Information for CAP 700 Before SetupFirst Installation Page Picture format TV aspect ratioTV Scart Output SystemLocal time offset Alignment Satellite Search Moving the Antenna Manually Channel Selection from the Channel List Channel Satellite SelectionMoving towards Change of LOCATION/TIMER ProgrammingTimer Programming Resetting the Turn Table Antenna RESET/PARKINGParking the Turntable System Protection Messages Special Messages from the TurntableSpecial Messages from the Turntable Messages Arising from Software Problems Further Messages Declaration of Conformity For Your Notes 936.3417/-/0908/ZWT Technical data subject to change