5.3.3.7FIRE TROUBLE

The Fire Trouble alarm item monitors the fire alarm system in the structure. A "None" alarm message indicates that no alarm is present and that the fire alarm system is operating normally. A "Fault" alarm message indicates that an alarm is present and the fire alarm system is malfunctioning.

This is a self-clearing alarm and will reset itself when the alarm condition no longer exists. This is a medium priority alarm.

5.3.3.8FIRE ALARM

The Fire Alarm item monitors the fire alarm system in the structure. A "None" alarm message indicates that no alarm is present and that the fire alarm system has not detected a fire. A "Fault" alarm message indicates that an alarm is present and that the fire alarm system has detected a fire in the structure.

This is a self-clearing alarm and will reset itself when the alarm condition no longer exists. This is a critical priority alarm.

5.3.3.9OUTDOOR TEMP ALARM

The Outdoor temperature alarm item will show one of two different alarm messages. A No alarm message indicates that the Outdoor Temperature Sensor is functioning normally. A Fault alarm message indicates that the Outdoor Temperature Sensor is sensing a value above 120 Fo or below -20 Fo. This probably indicates a faulty sensor.

These are all self-clearing alarms and will reset themselves when the alarm condition no longer exists. This is a critical alarm.

5.3.3.10OUTDOOR HUMIDITY ALARM

The Outdoor Humidity Alarm item will show one of two different alarm messages. A No alarm message indicates that the Outdoor Humidity Sensor is functioning normally. A Fault alarm message indicates that the Outdoor Humidity Sensor is sensing a value above 99 % RH or below 2 % RH. This probably indicates a faulty sensor. When a Outdoor Humidity Fault alarm is detected, the Outdoor Humidity value defaults to 50 % RH until the sensor is replaced.

These are all self-clearing alarms and will reset themselves when the alarm condition no longer exists. This is a medium priority alarm.

5.3.3.11DOOR ALARM

The Door Alarm item monitors the door switch in the structure. A "None" alarm message indicates that no alarm is present and that the door is closed. A "Fault" alarm message indicates that an alarm is present and that the door in the structure is open.

This is a self-clearing alarm and will reset itself when the alarm condition no longer exists. This is a critical priority alarm.

2100-444-003A

Page 34

Image 40
Contents Operations Manual Table Of Contents Operation Unit Status Screen PC Software Operation Table of Figures and Tables Package Contents Shipping DamageAdditional Requirements Copyright NoticeGeneral Building Points to be MonitoredWallmount Points to be Monitored for Each Unit Building Points to be ControlledSystem Points to be Controlled Alarm PointsWallmount Points to be Controlled Inputs Electrical Specifications Mechanical SpecificationsEnvironmental Specifications Model NomenclatureSensor Specifications Temperature Sensors Indoor and OutdoorHumidity Sensors Compressor Current SensorBlower Airflow Switch Front Cover Control Location Mounting Template High Voltage Wiring WiringMounting Wiring LOW Voltage Wiring SensorsOutdoor Temperature Sensor OTS Zone Temperature Sensor ZTSWiring Inputs & Outputs Wiring Telephone Line Wiring EthernetExternal Wiring Internal Wiring Power Backup System Installation Check List Wallmount Startup Checklist System Startup2 TCS22 Startup Checklist Sequence of Operation Cooling Sequence with EconomizersHeating Sequence FAN SequenceOccupied / Unoccupied Mode Sequence Alarm SequencePage Power Management Sequence Dehumidification SequenceThermal Shock Protection Sequence Modem SequenceDisplay & Keypad Physicals SetpointsPower Up Menu TreeBuildings Status Screen Unit StatusRoom Temperature Outdoor TemperatureRoom Humidity Outdoor HumidityRoom Occupied YES/NO Free CoolingOutdoor Enthalpy Unit Status Screen Unit #1 EconomizerUnit #1 Compressor Unit #1 HeaterUnit #1 Discharge AIR Temperature Alarms MenuUnit #1 Filter Space Temp Alarm Space Humidity Alarm3.5 #1 Filter Alarm 3.4 #1 Compressor AlarmUtility Power Fail Fire Alarm Outdoor Temp AlarmOutdoor Humidity Alarm Door AlarmSetpoints Screen Occupied Cooling Setpoint Unoccupied Cooling SetpointHigh Temperature Alarm Setpoint LOW Temperature Alarm SetpointHigh Humidity Alarm Setpoint LOW Humidity Alarm SetpointFree Cooling Enthalpy Setpoint Free Cooling DRY Bulb SetpointEnthalpy Lookup Table Overrides Unit #1 Screen5.1 #1 Blower Override 5.3 #1 Compressor Override 5.2 #1 Economizer Override5.4 #1 Heater Override Continuous Blower Enables Menu DRY Bulb Temperature Changeover Economizer OperationFree Cooling Enthalpy Changeover Daylight Savings TimePassword Operation Entering PasswordKeyboard Map UNIT#1 Comp OFF Room RH Installation Software InstallationClimateWatch System Software Overview Hardware RequirementsScreen Overview ASI Expert / Bard ClimateWatch SoftwareMenu Bar Tool Bar Status BarController Information Area Project FoldersSoftware Setup TCS CommunicationsCreating a New Project & Establishing Communications Direct Connection Remote Connection Page Downloading Controller Information Page Page Loading TCS Configuration Saving TCS ConfigurationTCS Controller Information Screens Main Screen TAB ConditionsUnit #2 Status Unit #1 StatusTime & Place SET Point TAB Occupied Cooling SetpointHigh Temperature Alarm SetPoint Unoccupied Cooling SetpointOccupied Heating Setpoint Unoccupied Heating SetpointLow Temperature Alarm SetPoint High Humidity Alarm SetPointLow Humidity Alarm SetPoint Enthalpy Changeover SetpointContinuous Blower Enable Dry Bulb Changeover SetpointDehumidification Setpoint Active Cooling SetpointActive Dehumidification Setpoint Stage IndicatorsOverride #1 TAB Page Unit #1 Compressor Unit #1 Economizer Alarms TAB Unit #1 Filter Alarm Unit #1 Compressor AlarmUnit #1 Blower Alarm Zone Temperature AlarmZone Humidity Alarm Outdoor Temperature AlarmOutdoor Humidity Alarm Main Power AlarmFire Trouble Alarm Alarm LOG TAB Zone Temperature Offset Outdoor Temperature OffsetOffsets TAB Zone Humidity OffsetOutdoor Humidity Offset Unit #1 Supply Air Temperature OffsetMISC. TAB Clear Alarm Event Log Enable Economizer OperationEnable Daylight Savings Time Enable 50 hz ClockEnable Zone Dehumidification Model NumberModel Serial Number SoftwareTrend TAB Dial OUT TAB Page 2100-444-003A Troubleshooting Routine Maintenance1 TCS22 Troubleshooting To F on the terminal strip on controller Will correspond with the Humidity Page Humidity Sensor Output Thermistor Resistance Vs. Temperature Table Operation Procedure Wallmount Quick Troubleshooting Guide

TCS22-***-003 specifications

The Bard TCS22-***-003 is a cutting-edge technological marvel designed for modern thermal management solutions. This unit is revered in the HVAC industry for its innovative features and energy-efficient operation, making it a popular choice among both commercial and residential users.

One of the main features of the Bard TCS22-***-003 is its advanced climate control capabilities. Equipped with state-of-the-art sensors, the unit provides precise temperature regulation, ensuring optimal comfort in interior spaces. The system's intelligence allows it to adapt to varying weather conditions, maintaining consistent indoor temperatures even during extreme external fluctuations.

The Bard TCS22-***-003 also sports a robust energy efficiency rating, setting it apart from traditional heating and cooling systems. With the integration of variable speed technology, the unit optimizes energy usage by adjusting its output based on the current load. This not only reduces energy consumption but also results in lowered utility bills, promoting sustainability and eco-friendly living.

Another notable characteristic is its whisper-quiet operation. Noise reduction has been a focal point in the design of the TCS22-***-003, allowing it to function below typical sound levels associated with conventional HVAC systems. This is particularly beneficial for residential applications where noise pollution can disrupt daily activities.

The unit is built with durability in mind, featuring a weatherproof construction that can withstand various environmental conditions. Its exterior casing prevents moisture infiltration, while corrosion-resistant materials enhance its longevity. As a result, maintenance needs are minimized, further establishing the Bard TCS22-***-003 as a cost-effective solution in the long run.

In addition, the Bard TCS22-***-003 integrates smart technology, enabling users to control the system remotely using mobile devices or smart home automation systems. This level of convenience allows for personalized heating and cooling settings tailored to individual preferences and schedules.

Overall, the Bard TCS22-***-003 is a standout in the HVAC market due to its blend of efficiency, performance, and user-friendly features. Whether for a home or a commercial establishment, this innovative system offers reliable and sustainable climate control solutions that cater to the needs of today's environmentally conscious consumers.