Entering the O/R On action will turn on the heater output to unit #1 and it will remain on until cleared. Entering the O/R Off action will disable the output to the unit #1 heater and it will remain disabled until cleared. Once overridden the output will remain overridden until the Clr O/R action is sent to the output or power is interrupted to the controller. Use the Clr O/R to cancel an override action and resume normal operation.

A supervisor authority level is needed to use this item.

5.3.5.5 CONTINUOUS BLOWER

This item uses the On and Off action items. Overriding the continuous blower item to On causes the Blower Output to the lead unit to be energized continuously. Overriding the continuous blower item to Off causes the Blower Output to the lead unit to cycle on and off as there are calls for heating or cooling.

An operator authority level is needed to use this item.

2100-444-003A

Page 42

Image 48
Contents Operations Manual Table Of Contents Operation Unit Status Screen PC Software Operation Table of Figures and Tables Package Contents Shipping DamageAdditional Requirements Copyright NoticeGeneral Building Points to be MonitoredWallmount Points to be Monitored for Each Unit Building Points to be ControlledAlarm Points System Points to be ControlledWallmount Points to be Controlled Inputs Electrical Specifications Mechanical SpecificationsEnvironmental Specifications Model NomenclatureSensor Specifications Temperature Sensors Indoor and OutdoorHumidity Sensors Compressor Current SensorBlower Airflow Switch Front Cover Control Location Mounting Template Wiring High Voltage WiringMounting Wiring LOW Voltage Wiring SensorsOutdoor Temperature Sensor OTS Zone Temperature Sensor ZTSWiring Inputs & Outputs Wiring Telephone Line Wiring EthernetExternal Wiring Internal Wiring Power Backup System Installation Check List Wallmount Startup Checklist System Startup2 TCS22 Startup Checklist Sequence of Operation Cooling Sequence with EconomizersHeating Sequence FAN SequenceOccupied / Unoccupied Mode Sequence Alarm SequencePage Power Management Sequence Dehumidification SequenceThermal Shock Protection Sequence Modem SequenceDisplay & Keypad Physicals SetpointsPower Up Menu TreeBuildings Status Screen Unit StatusRoom Temperature Outdoor TemperatureRoom Humidity Outdoor HumidityFree Cooling Room Occupied YES/NOOutdoor Enthalpy Unit Status Screen Unit #1 EconomizerUnit #1 Compressor Unit #1 HeaterAlarms Menu Unit #1 Discharge AIR TemperatureUnit #1 Filter Space Temp Alarm Space Humidity Alarm3.4 #1 Compressor Alarm 3.5 #1 Filter AlarmUtility Power Fail Fire Alarm Outdoor Temp AlarmOutdoor Humidity Alarm Door AlarmSetpoints Screen Occupied Cooling Setpoint Unoccupied Cooling SetpointHigh Temperature Alarm Setpoint LOW Temperature Alarm SetpointHigh Humidity Alarm Setpoint LOW Humidity Alarm SetpointFree Cooling Enthalpy Setpoint Free Cooling DRY Bulb SetpointEnthalpy Lookup Table Overrides Unit #1 Screen5.1 #1 Blower Override 5.2 #1 Economizer Override 5.3 #1 Compressor Override5.4 #1 Heater Override Continuous Blower Enables Menu DRY Bulb Temperature Changeover Economizer OperationFree Cooling Enthalpy Changeover Daylight Savings TimePassword Operation Entering PasswordKeyboard Map UNIT#1 Comp OFF Room RH Installation Software InstallationClimateWatch System Software Overview Hardware RequirementsASI Expert / Bard ClimateWatch Software Screen OverviewMenu Bar Tool Bar Status BarController Information Area Project FoldersSoftware Setup TCS CommunicationsCreating a New Project & Establishing Communications Direct Connection Remote Connection Page Downloading Controller Information Page Page Saving TCS Configuration Loading TCS ConfigurationTCS Controller Information Screens Main Screen TAB ConditionsUnit #1 Status Unit #2 StatusTime & Place SET Point TAB Occupied Cooling SetpointHigh Temperature Alarm SetPoint Unoccupied Cooling SetpointOccupied Heating Setpoint Unoccupied Heating SetpointLow Temperature Alarm SetPoint High Humidity Alarm SetPointLow Humidity Alarm SetPoint Enthalpy Changeover SetpointContinuous Blower Enable Dry Bulb Changeover SetpointDehumidification Setpoint Active Cooling SetpointStage Indicators Active Dehumidification SetpointOverride #1 TAB Page Unit #1 Compressor Unit #1 Economizer Alarms TAB Unit #1 Filter Alarm Unit #1 Compressor AlarmUnit #1 Blower Alarm Zone Temperature AlarmZone Humidity Alarm Outdoor Temperature AlarmOutdoor Humidity Alarm Main Power AlarmFire Trouble Alarm Alarm LOG TAB Zone Temperature Offset Outdoor Temperature OffsetOffsets TAB Zone Humidity OffsetUnit #1 Supply Air Temperature Offset Outdoor Humidity OffsetMISC. TAB Clear Alarm Event Log Enable Economizer OperationEnable Daylight Savings Time Enable 50 hz ClockEnable Zone Dehumidification Model NumberModel Serial Number SoftwareTrend TAB Dial OUT TAB Page 2100-444-003A Routine Maintenance Troubleshooting1 TCS22 Troubleshooting To F on the terminal strip on controller Will correspond with the Humidity Page Humidity Sensor Output Thermistor Resistance Vs. Temperature Table Operation Procedure Wallmount Quick Troubleshooting Guide

TCS22-***-003 specifications

The Bard TCS22-***-003 is a cutting-edge technological marvel designed for modern thermal management solutions. This unit is revered in the HVAC industry for its innovative features and energy-efficient operation, making it a popular choice among both commercial and residential users.

One of the main features of the Bard TCS22-***-003 is its advanced climate control capabilities. Equipped with state-of-the-art sensors, the unit provides precise temperature regulation, ensuring optimal comfort in interior spaces. The system's intelligence allows it to adapt to varying weather conditions, maintaining consistent indoor temperatures even during extreme external fluctuations.

The Bard TCS22-***-003 also sports a robust energy efficiency rating, setting it apart from traditional heating and cooling systems. With the integration of variable speed technology, the unit optimizes energy usage by adjusting its output based on the current load. This not only reduces energy consumption but also results in lowered utility bills, promoting sustainability and eco-friendly living.

Another notable characteristic is its whisper-quiet operation. Noise reduction has been a focal point in the design of the TCS22-***-003, allowing it to function below typical sound levels associated with conventional HVAC systems. This is particularly beneficial for residential applications where noise pollution can disrupt daily activities.

The unit is built with durability in mind, featuring a weatherproof construction that can withstand various environmental conditions. Its exterior casing prevents moisture infiltration, while corrosion-resistant materials enhance its longevity. As a result, maintenance needs are minimized, further establishing the Bard TCS22-***-003 as a cost-effective solution in the long run.

In addition, the Bard TCS22-***-003 integrates smart technology, enabling users to control the system remotely using mobile devices or smart home automation systems. This level of convenience allows for personalized heating and cooling settings tailored to individual preferences and schedules.

Overall, the Bard TCS22-***-003 is a standout in the HVAC market due to its blend of efficiency, performance, and user-friendly features. Whether for a home or a commercial establishment, this innovative system offers reliable and sustainable climate control solutions that cater to the needs of today's environmentally conscious consumers.