Bard TCS22-***-003 manual UNIT#1 Comp OFF Room RH

Page 53

Screen 1

 

 

Screen 2

 

 

 

Screen 3

 

 

 

 

 

 

 

 

12/01/96 8:45 AM

 

 

 

 

 

 

 

NO ALARMS

 

UNIT STATUS

 

 

ALARMS

 

 

 

 

 

 

 

F1 = EDIT MODE

BUILDING STATUS

 

 

 

 

 

ENTER TO EDIT

 

 

 

 

 

 

 

 

 

 

 

 

UNIT#1 ECON.

OFF

 

 

 

 

ROOM TEMP.

75.59F

 

UNIT#1 COMP.

OFF

 

 

 

 

ROOM RH

39.4RH

 

UNIT#1 HEAT

ON

 

NOP

= NO OPERATION

OD TEMP.

73.11F

 

UNIT#1 BLOWER

OFF

 

ACK

= ACKNOWLEDGE

OUTDOOR RH

40.9RH

 

UNIT#1FILTER

CLEAN

 

CRAM= CLEAR ALR RAM

ACTIVE CLG.SP

80.00F

 

U#1 SUPPLY AIR

90.24

 

ACKA= ACKNOWLEDGE ALL

ACTIVE HTG.SP

68.00F

 

 

 

 

CAF

= CLEAR ALR FLAG

FREE COOLING

NO

 

UNIT#2 ECON.

OFF

 

 

 

 

LEAD UNIT

2

 

UNIT#2 COMP.

OFF

 

ALARM

TYP ACK A

SHELTER POWER

UTIL

 

UNIT#2 HEAT

OFF

 

ZONE TEMP

 

ROOM OCCUPIED

NO

 

UNIT#2 BLOWER

OFF

 

ZONE HUMID

 

OD ENTHALPY

25.44

 

UNIT#2 FILTER

CLEAN

 

U1 BLOWER

 

 

 

 

 

 

 

U1 COMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U1 FILTER

 

 

 

 

 

 

 

U2 BLOWER

 

 

 

 

 

 

 

U2 COMP

 

 

 

 

 

 

 

U2 FILTER

 

 

 

 

 

 

 

UTL POW FAIL

 

 

 

 

 

 

 

FIRE ALARM

 

 

 

 

 

 

 

FIRE TROUBLE

 

 

 

 

 

 

 

OUTDOOR TEMP.

 

 

 

 

 

 

OUTDOOR HUM.

 

 

 

 

 

 

DOOR ALARM

 

 

 

 

 

 

 

 

 

 

Screen 4

 

Screen 5

 

 

Screen 6

 

 

Screen 7

 

 

 

 

 

 

 

 

SETPOINTS

 

OVERRIDES

 

OVERRIDES

 

 

ENABLES

F1 = EDIT MODE

 

UNIT #1

 

 

UNIT #2

 

 

F1 = EDIT MODE

ENTER TO EDIT

 

 

 

 

 

 

 

 

 

ENTER TO EDIT

 

 

 

 

 

 

 

 

 

 

 

F1 = EDIT MODE

 

 

F1 = EDIT MODE

 

 

 

Occ. Cooling SP

 

ENTER TO EDIT

 

 

ENTER TO EDIT

 

 

Enable Econ.

75.00 F

 

BLOWER

 

OFF

 

BLOWER

 

OFF

 

ENABLED

Unocc. Clg. SP

 

OVR STATUS

 

AUTO

 

OVR STATUS

 

AUTO

 

 

80.00 F

 

VERIFY ALN STAT

OK

 

VERIFY ALN STAT

OK

 

FC DB CHANGEOVER

Occ. Heating SP

 

ACTION

NO OPER.

 

ACTION

NO OPER.

 

DISABLED

70.00 F

 

 

 

 

 

 

 

 

 

 

Unocc. Htg. SP

 

ECON OUTPUT

OFF

 

ECON OUTPUT

OFF

 

FC ENTH. CHANGEOVER

68.00 F

 

OVR STATUS

 

AUTO

 

OVR STATUS

 

AUTO

 

ENABLED

Hi Temp Alarm SP

 

ACTION

NO OPER.

 

ACTION

NO OPER.

 

 

87.00 F

 

 

 

 

 

 

 

 

 

DAYLIGHT SAVINGS TIME

Lo Temp Alarm SP

 

COMP.

 

OFF

 

COMP.

 

OFF

 

ENABLED

56.00 F

 

OVR STATUS

 

AUTO

 

OVR STATUS

 

AUTO

 

 

Hi Humidity SP

 

VERIFY ALN STAT

OK

 

VERIFY ALN STAT

OK

 

50HZ CLOCK

80.0 RH

 

ACTION

NO OPER.

 

ACTION

NO OPER.

 

DISABLED

Low Humidity SP

 

 

 

 

 

 

 

 

 

 

20.0 RH

 

HEAT OUTPUT

OFF

 

HEAT OUTPUT

OFF

 

ZONE HUMID. SENSOR

Dehum. Setpoint

 

OVR STATUS

 

AUTO

 

OVR STATUS

 

AUTO

 

ENABLED

60.0 RH

 

ACTION

NO OPER.

 

ACTION

NO OPER.

 

 

Changeover Time

 

 

 

 

 

 

 

 

 

ZONE DEHUMID CONTROL

 

 

 

 

 

 

 

 

 

24 HRS

 

 

 

 

 

 

 

 

 

DISABLED

FC Enth Setpoint

 

LEAD UNIT IS

2

 

 

 

 

 

 

 

23.00 BTU/LB

 

CHANGE LEAD UNIT ***

 

 

 

 

 

TCS MODEL NUMBER

FC DB Setpoint

 

 

 

 

 

 

 

 

 

************

48.00 F

 

CONT. BLOWER

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TCS SERIAL NUMBER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

************

 

 

 

 

 

 

 

 

 

 

 

2100-444-003A Page 47

Image 53
Contents Operations Manual Table Of Contents Operation Unit Status Screen PC Software Operation Table of Figures and Tables Shipping Damage Package ContentsAdditional Requirements Copyright NoticeBuilding Points to be Monitored GeneralWallmount Points to be Monitored for Each Unit Building Points to be ControlledWallmount Points to be Controlled Alarm PointsSystem Points to be Controlled Inputs Mechanical Specifications Electrical SpecificationsEnvironmental Specifications Model NomenclatureTemperature Sensors Indoor and Outdoor Sensor SpecificationsHumidity Sensors Compressor Current SensorBlower Airflow Switch Front Cover Control Location Mounting Template Mounting WiringHigh Voltage Wiring Wiring Sensors Wiring LOW VoltageOutdoor Temperature Sensor OTS Zone Temperature Sensor ZTSWiring Inputs & Outputs Wiring Ethernet Wiring Telephone LineExternal Wiring Internal Wiring Power Backup System Installation Check List System Startup Wallmount Startup Checklist2 TCS22 Startup Checklist Cooling Sequence with Economizers Sequence of OperationHeating Sequence FAN SequenceAlarm Sequence Occupied / Unoccupied Mode SequencePage Dehumidification Sequence Power Management SequenceThermal Shock Protection Sequence Modem SequenceSetpoints Display & Keypad PhysicalsMenu Tree Power UpUnit Status Buildings Status ScreenOutdoor Temperature Room TemperatureRoom Humidity Outdoor HumidityOutdoor Enthalpy Free CoolingRoom Occupied YES/NO Unit #1 Economizer Unit Status ScreenUnit #1 Compressor Unit #1 HeaterUnit #1 Filter Alarms MenuUnit #1 Discharge AIR Temperature Space Humidity Alarm Space Temp AlarmUtility Power Fail 3.4 #1 Compressor Alarm3.5 #1 Filter Alarm Outdoor Temp Alarm Fire AlarmOutdoor Humidity Alarm Door AlarmSetpoints Screen Unoccupied Cooling Setpoint Occupied Cooling SetpointLOW Temperature Alarm Setpoint High Temperature Alarm SetpointHigh Humidity Alarm Setpoint LOW Humidity Alarm SetpointFree Cooling DRY Bulb Setpoint Free Cooling Enthalpy SetpointOverrides Unit #1 Screen Enthalpy Lookup Table5.1 #1 Blower Override 5.4 #1 Heater Override 5.2 #1 Economizer Override5.3 #1 Compressor Override Continuous Blower Enables Menu Economizer Operation DRY Bulb Temperature ChangeoverFree Cooling Enthalpy Changeover Daylight Savings TimeEntering Password Password OperationKeyboard Map UNIT#1 Comp OFF Room RH Software Installation InstallationClimateWatch System Software Overview Hardware RequirementsMenu Bar ASI Expert / Bard ClimateWatch SoftwareScreen Overview Status Bar Tool BarController Information Area Project FoldersTCS Communications Software SetupCreating a New Project & Establishing Communications Direct Connection Remote Connection Page Downloading Controller Information Page Page TCS Controller Information Screens Saving TCS ConfigurationLoading TCS Configuration Conditions Main Screen TABTime & Place Unit #1 StatusUnit #2 Status Occupied Cooling Setpoint SET Point TABUnoccupied Cooling Setpoint High Temperature Alarm SetPointOccupied Heating Setpoint Unoccupied Heating SetpointHigh Humidity Alarm SetPoint Low Temperature Alarm SetPointLow Humidity Alarm SetPoint Enthalpy Changeover SetpointDry Bulb Changeover Setpoint Continuous Blower EnableDehumidification Setpoint Active Cooling SetpointOverride #1 TAB Stage IndicatorsActive Dehumidification Setpoint Page Unit #1 Compressor Unit #1 Economizer Alarms TAB Unit #1 Compressor Alarm Unit #1 Filter AlarmUnit #1 Blower Alarm Zone Temperature AlarmOutdoor Temperature Alarm Zone Humidity AlarmOutdoor Humidity Alarm Main Power AlarmFire Trouble Alarm Alarm LOG TAB Outdoor Temperature Offset Zone Temperature OffsetOffsets TAB Zone Humidity OffsetMISC. TAB Unit #1 Supply Air Temperature OffsetOutdoor Humidity Offset Enable Economizer Operation Clear Alarm Event LogEnable Daylight Savings Time Enable 50 hz ClockModel Number Enable Zone DehumidificationModel Serial Number SoftwareTrend TAB Dial OUT TAB Page 2100-444-003A 1 TCS22 Troubleshooting Routine MaintenanceTroubleshooting To F on the terminal strip on controller Will correspond with the Humidity Page Humidity Sensor Output Thermistor Resistance Vs. Temperature Table Wallmount Quick Troubleshooting Guide Operation Procedure

TCS22-***-003 specifications

The Bard TCS22-***-003 is a cutting-edge technological marvel designed for modern thermal management solutions. This unit is revered in the HVAC industry for its innovative features and energy-efficient operation, making it a popular choice among both commercial and residential users.

One of the main features of the Bard TCS22-***-003 is its advanced climate control capabilities. Equipped with state-of-the-art sensors, the unit provides precise temperature regulation, ensuring optimal comfort in interior spaces. The system's intelligence allows it to adapt to varying weather conditions, maintaining consistent indoor temperatures even during extreme external fluctuations.

The Bard TCS22-***-003 also sports a robust energy efficiency rating, setting it apart from traditional heating and cooling systems. With the integration of variable speed technology, the unit optimizes energy usage by adjusting its output based on the current load. This not only reduces energy consumption but also results in lowered utility bills, promoting sustainability and eco-friendly living.

Another notable characteristic is its whisper-quiet operation. Noise reduction has been a focal point in the design of the TCS22-***-003, allowing it to function below typical sound levels associated with conventional HVAC systems. This is particularly beneficial for residential applications where noise pollution can disrupt daily activities.

The unit is built with durability in mind, featuring a weatherproof construction that can withstand various environmental conditions. Its exterior casing prevents moisture infiltration, while corrosion-resistant materials enhance its longevity. As a result, maintenance needs are minimized, further establishing the Bard TCS22-***-003 as a cost-effective solution in the long run.

In addition, the Bard TCS22-***-003 integrates smart technology, enabling users to control the system remotely using mobile devices or smart home automation systems. This level of convenience allows for personalized heating and cooling settings tailored to individual preferences and schedules.

Overall, the Bard TCS22-***-003 is a standout in the HVAC market due to its blend of efficiency, performance, and user-friendly features. Whether for a home or a commercial establishment, this innovative system offers reliable and sustainable climate control solutions that cater to the needs of today's environmentally conscious consumers.