Applicable Models:
ES-9 Adjusting the Printing Darkness
1.Remove the control unit from the main unit. (Fig. 1)
2.Loosen four screws on the bottom of the control unit, and remove the cable connector from the unit. (Fig. 1)
3.Remove the black metal base on the bottom of the control unit. (Fig. 2)
4.Provisionally connect the 5P connector on the bottom of the control unit to the main unit.
5.Turn on the power. Check if the printer symbol appears on the LCD panel and the printer is in the operating condition.
6.Check if the thermal paper is set in position.
7.Adjustment should be done with the control unit positioned horizontally. Press the ADV button on the control panel twice to perform a test printing. A
NOTE: Never touch the potentiometer DCV.
Upright Type | Recumbent Type | Control Unit |
|
| |
Control Unit |
|
|
Cable Connector |
|
|
|
| Cable Connector |
Fig. 1 | Fig. 2 |
DCV | PR |
Potentiometer PR |
Fig. 3
ES-9 Adjusting the Printing Darkness
Cateye Ergociser Series 1000 Service Manual
33