Applicable Models: |
|
|
|
|
|
|
| |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
MS-20 Replacing the Center Cover of Recumbent Type
*Remove the pulse rate sensor, if it is connected, before proceeding to the following procedures.
1. | Remove the control unit fixing screws (4 pieces) from the main |
| unit. (Fig. 1) |
2. | Detach the cable connector from the control unit. (Fig. 2) |
3. | Loosen and remove the inner pipe from the joint metal base. |
| (Fig. 3) |
4. | Remove the frame cover fixing screws, and the frame cover |
| will be separated into right and left parts. (Fig. 4) |
5. | Remove the latch of the center cover from the frame cover, |
| and pull the center cover toward the joint metal base to remove |
| it. (Fig. 5) |
6. | Assembling of the center cover can be performed in reversed |
| procedure of the above. |
| * Pull the 5P cable connector out of the center cover through |
Control Unit |
Control Unit Fixing Screw |
Fig. 1
5P Cable
Fig. 2
Inner Pipe
Joint Metal Base
Fig. 3
the hole on the cover, and tentatively hold it with an |
adhesive tape so that it may not be retracted. |
Frame Cover
Fixing Screw
Frame Cover
Fig. 4
Center Cover |
EC- |
3600 |
Joint |
Fig. 5
MS-20 Replacing the Center Cover of Recumbent Type
Cateye Ergociser Series 1000 Service Manual
57