Cateye EC-3700, EC-3600 service manual Frame, ES-1Replacing the Wiring within

Page 26

Applicable Models: EC-1200 EC-1600 EC-3600 EC-3700

ES-1Replacing the Wiring within the Frame

[A] Removing the Wiring Parts

1.

Remove the frame cover. (See the Sections D-1 & D-2

 

"Removing the Frame Covers.")

2.

Loosen the two screws on the inlet metal base to remove

 

them. (Fig. 1)

3.

With the stopper being held with fingers, pull the CN-4

 

connector off the power supply board. (Fig. 2)

4.

Cut the cable holder with a nipper. (Fig. 3)

[B] Mounting the Brand New Wiring Parts

1.

Mount the brand new inlet metal base to the frame with two

 

screws.

2.

Pass the wiring cable from beneath the DC jack of the power

 

supply board along with the square pipe (21mm x 21mm) to

 

the left direction, and then pass it through the back of the inlet

 

metal base along with the square pipe toward the switch.

 

 

 

 

 

 

 

 

 

 

Inlet Metal Base

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inlet Metal Base

 

 

 

 

Power Supply Board

 

EC-3600 & EC-3700

EC-1200 & EC-1600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supply

Board

ON

OFF

the Frame

3.

Connect the CN-4 connector to the power supply board.

4.

Refer to the Section (2) "Checking the Wiring within the

 

Frame" of T-1 "No Display on the Control Unit after Power ON"

 

(1) , measure the voltage across the electrolytic capacitor C-1

 

to check that it is in the correct range of 14V and 19V.

5.

Use the cable holder to fix the CDC sensor cable together with

 

the solenoid coil cable. (Fig. 3)

6.

Provisionally connect the control unit, and check the unit works

 

fine after turning on the power. Then, completely assemble

 

the frame cover.

Inlet Metal Base (for Upright Type)

ON

Screws

DC Jack

 

 

OFF

Inlet Metal Base (for Recumbent Type)

ON

Screws

DC Jack

 

 

OFF

ES-1Replacing the Wiring within

Fig. 1

Power Supply Board

Hold the stopper.

Cable Holders

Fig. 2

Fig. 3

Cateye Ergociser Series 1000 Service Manual

24

Image 26
Contents Cateye Ergociser Index Applicable Models EC-1200 EC-1600 EC-3600 EC-3700ServiceManual Flywheelw/o TypeUpright ForParts OfName Applicable Models EC-1200Name of Parts for Upright Type w/o Flywheel Name of Parts for Upright Type w/ Flywheel EC-1600OfPartsforUpright FlywheelTypew NameName of Parts for Recumbent Type EC-3600 EC-3700OFF Name of Parts for Belt Drive Type ADDEC-3600B/EC-3700B EC-3600B/EC-3700BCircuit Diagram Circuit Diagram for Automatic Type Cateye ErgociserEC-1200 EC-1600 EC-3600 EC-3700 No Display on Control Unit after Power on1No Display on Control Unit after Power on Main unit in accordance with the following procedures Check Method of Causes Repair Method Explanation Figures2No Display of Cadence No Display of Pulse Rate No Printer Operation Printer is not used. Check if the No.4 select switch onDefective ES-3 Replacing the Power Supply Board EC-1600 EC-3700No Loading Check of mechanical systems Check Method of Causes Repair Method5No Loading Check of Electrical Systems Remove the connector CN-1 from the power supply boardNo Loading Check of Electrical Systems Section ES-2 Replacing the 5P CableEC-1600 EC-3600 EC-3700 No Pedal Rotation Locked6No Pedal Rotation Locked 1Unusual Noise 1Unusual Noise Continuous and IncreasingEC-1200 EC-1600 EC-3600 Flywheel set with new onesUnusual Noise Periodical 2Unusual NoiseNoise occurs when the pedal is rotated with a large torque 3Unusual Noise1Removing the Frame Covers 1Removing the Frame Covers2Removing the Frame Covers Remove the frame covers in the following proceduresRemoving the Frame Covers Side pedal can be removed by turning it in the clockwiseES-1Replacing the Wiring within FrameES-2Replacing the 5P Cable 2Replacing the 5P CableFrame Covers Control unit. Also, remove the cable connector. FigCable to the frame by using cable holders Cut the cable holders which fix the cable to remove the 5PSupply Board ES-3Replacing the Power Supply BoardES-3Replacing the Power Frame side Fig Metal base in the following procedures. FigWhen the main unit is viewed from the direction as depicted , fasten the frame-side nutES-5Replacing the CDC Sensor ES-5Replacing the CDC SensorES-6Replacing the Panel Keyboard Replacing the Panel KeyboardES-7Replacing the Button Panel ES-7Replacing the Button PanelReplacing the Printer ES-8Replacing the PrinterES-9Adjusting the Printing Darkness ES-9Adjusting the Printing DarknessPaper Jamming in Printer ES-10Paper Jamming in PrinterEC-1200 Workload Unit w/o FlywheelMS-1Replacing Assemble the chain. Chain should first be set on the free Wheel before setting it to the upper part of the large gearSetting on the large gear. Fig Tension to the chain. FigMS-1Replacing the Workload Unit w/o Flywheel ÀMounting the Brandnew Workload Unit FlywheelMS-2Replacing the Workload Unit EC-1600 EC-3600 MS-3Adjusting the FlywheelMS-3Adjusting the Flywheel MS-4Replacing the Chain MS-5Replacing the Free Wheel Set MS-5Replacing the Free Wheel SetMS-6Replacing the Derailleur Set MS-7Replacing the Idler Set MS-7Replacing the Idler SetMS-8Replacing the Crank Set MS-8Replacing the Crank SetShould be adjusted as illustrated in Fig Fasten the crank cap by using a coin, etc. FigEnable the complete setting of the gear. Fig Adjust the clearance between the magnet mounted onMS-9Replacing the BB Set 9Replacing the BB SetMS-10Replacing the Post Spacer MS-10Replacing the Post SpacerMS-11Adjusting the Spacer Spring MS-11Adjusting the Spacer SpringMS-12Replacing the Inner Pipe Spacer MS-12Replacing the Inner Pipe SpacerMS-13Replacing the Vertical Pipe Spacer EC-3600 EC-3700 MS-13Replacing the Vertical Pipe SpacerMS-14Replacing the Leg Cover MS-14Replacing the Leg CoverEC-3600 EC-3700 MS-15Replacing the Caster and Level Adjuster MS-16Replacing the Seat Post Knob MS-16Replacing the Seat Post KnobMS-17Replacing the Lock Pin EC-3600 EC-3700 MS-17Replacing the Lock PinÀREMOVAL Remove both right and left pedals. Fig MS-18Replacing the Crank CoverMS-19Replacing the Crank Cover Set the right and left pedals1200, remove the cable holder from the handlebar post MS-19Replacing the Center Cover of Upright TypeEC-1200 EC-1600 MS-20Replacing the Center Cover of Recumbent Type MS-21Replacing the Handlebar Grip MS-22Replacing the Printer Cover MS-22Replacing the Printer CoverMS-23Replacing the Paper Cutter MS-23Replacing the Paper CutterList of Genuin Parts PNR.780-5160 EC-1600/3700 Panel Keybord unit setsApplicable Models EC-1200EC-1600 PNR.781-5520 EC-3600 Crank CoverL,RSet unit sets Unit sets PNR.781-5580 Unit sets 1000 PNR.701-6701 Wireless Heart Rate Senaor Kit TMParts PNR.000-0000 HR Senaor Belt unit setsUnit sets Unit pieces P8M15-1192 PNR.724-1022 Applicable Models EC-1200B EC-1600B EC-3600B EC-3700BList of Genuin Parts Belt Drive Unit pieces P8M15-1080List of Genuin Parts Applicable Models EC-1200 EC-1600 EC-3600 EC-3700